Skip to main content

What are Temora Council's setbacks for a house, granny flat or duplex?

A setback is how far a home must sit from each boundary of its lot. In Temora the setbacks for a house, a granny flat or a duplex come from Temora Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page reads what we hold for each of the three.

It is a first look. Enter your address and the Site Checker opens at the setbacks for your lot, from the plan that covers it.

Check your address

NSW addresses only. Free, and no sign up.

What are Temora Council's setbacks for a house?

Temora Council's main plan, Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1), asks a single storey house for these setbacks: front 6m, side 0.9m and rear 3m.

House setbacks in Temora gives the two storey figures, the clauses and every other plan that covers one.

What are Temora Council's setbacks for a granny flat?

Temora Council's main plan, Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1), asks a single storey granny flat for these setbacks: front 6m, side 0.9m and rear 3m.

Granny flat setbacks in Temora gives the two storey figures, the clauses and every other plan that covers one.

What are Temora Council's setbacks for a duplex?

Temora Council's main plan, Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1), asks a single storey duplex for these setbacks: front 6m, side 0.9m and rear 3m.

Duplex setbacks in Temora gives the two storey figures, the clauses and every other plan that covers one.

Which DCP covers my block in Temora?

It depends on the lot: we hold 6 plans with setbacks for homes in Temora Council, and Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1) is the main one. The others cover particular land, such as precincts, estates, rural land or former council areas. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot.

Every plan in Temora with setbacks for homes
PlanWhere it appliesHomes it covers
Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1)Main plan. Land zoned R1 General Residential (Temora town, about 369 ha).house, granny flat, duplex
Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (RU5 villages and MU1)Land zoned RU5 Village (Ariah Park and Springdale, about 160 ha) and MU1 Mixed Use (Temora town, 34 ha).house, granny flat, duplex
Temora Shire DCP 2012, Temora Airpark EstateThe Temora Airpark Estate, "bounded by Airport Street, Bartondale Road, Derricks Road and Barmedman Road" (chapter s 2): the SP1 Special Activities land beside Temora Airport marked "Business Premises, Residential, Tourist and Visitor Accommodation, incidental with aviation" on the Temora LEP 2010 Land Zoning Map (one polygon, 68.7 ha, 140 current lots, checked over the aerial).house
Temora Shire DCP 2012, Large Lot Residential Development (R5)Land zoned R5 Large Lot Residential (about 432 ha around Temora town and 36 ha at Ariah Park), other than the Bundawarrah Estate Master Plan study area, which has its own plan with the same figures.house, granny flat, duplex
Temora Shire DCP 2012, Bundawarrah Estate Master Plan (R5)The Bundawarrah Estate Master Plan study area, "bordered by Evatt Street to the north, Narraburra Street to the east, Milvale Road/Loftus Street to the south and Bundawarrah Road to the west" (chapter s 3, Figure 1): R5 land on the east edge of Temora town.house, granny flat, duplex
Temora Shire DCP 2012, Rural Development (RU1)Land zoned RU1 Primary Production (most of the shire).house, granny flat, duplex

Do Temora Council's setbacks apply to complying development?

No. A home approved with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, follows the state codes' setbacks instead of the council's. On a 600m² (15m wide, 40m deep) lot, for example, the Site Checker reads the complying development setbacks for a house as front 4.5m, side 0.9m (1.5m at two storeys) and rear 3m (8m at two storeys).

The council's plan applies when you lodge a development application. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more.

What setbacks apply on a corner block in Temora?

Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1) sets a separate setback for a house from the second street, the side street of a corner block: 3m (Residential Development, s 3, Side and Rear Setbacks). The front setback still applies to the main street. Under complying development the code sets its own second street figure by lot size.

What else do people ask?

Can Temora Council approve a smaller setback?

It can, through a development application. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more.

Do Temora setbacks apply to sheds, pools and fences?

Not the ones on this page. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.

When were Temora Council's setbacks checked?

We last read Temora Council's plans on 12 November 2026. Each plan links to the council's own document, so you can check a figure against the current version.

Where does this information come from?

These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.

What else can I check?

Check what applies to your block