Temora Council's main plan, Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1), asks a single storey house for these setbacks: front 6m, side 0.9m and rear 3m.
In Temora the setbacks for a house come from Temora Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the house first.
NSW addresses only. Free, and no sign up.
What setbacks does Temora Council's main plan set for a house?
The table gives Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1)'s one and two storey figures and the clause each comes from. The plan covers this land: Land zoned R1 General Residential (Temora town, about 369 ha).
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | 6m | 6m | Residential Development, s 3 Specific Development Controls, Front Setbacks |
| Side | 0.9m | 0.9m | Residential Development, s 3, Side and Rear Setbacks |
| Rear | 3m | 3m | Residential Development, s 3, Side and Rear Setbacks |
| Corner block, second street | 3m | 3m | Residential Development, s 3, Side and Rear Setbacks |
Which DCP applies to my block in Temora?
It depends on where the lot is. Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1) is Temora Council's main plan, and 5 other plans cover a house on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (RU5 villages and MU1) | Land zoned RU5 Village (Ariah Park and Springdale, about 160 ha) and MU1 Mixed Use (Temora town, 34 ha). | 6m | 0.9m | 3m | 3m |
| Temora Shire DCP 2012, Temora Airpark Estate | The Temora Airpark Estate, "bounded by Airport Street, Bartondale Road, Derricks Road and Barmedman Road" (chapter s 2): the SP1 Special Activities land beside Temora Airport marked "Business Premises, Residential, Tourist and Visitor Accommodation, incidental with aviation" on the Temora LEP 2010 Land Zoning Map (one polygon, 68.7 ha, 140 current lots, checked over the aerial). | the average of the neighbouring homes (5.5m where there are none) | not set by the DCP: ask the council | not set by the DCP: ask the council | not set |
| Temora Shire DCP 2012, Large Lot Residential Development (R5) | Land zoned R5 Large Lot Residential (about 432 ha around Temora town and 36 ha at Ariah Park), other than the Bundawarrah Estate Master Plan study area, which has its own plan with the same figures. | 30m | 30m | 30m | 30m |
| Temora Shire DCP 2012, Bundawarrah Estate Master Plan (R5) | The Bundawarrah Estate Master Plan study area, "bordered by Evatt Street to the north, Narraburra Street to the east, Milvale Road/Loftus Street to the south and Bundawarrah Road to the west" (chapter s 3, Figure 1): R5 land on the east edge of Temora town. | 30m | 30m | 30m | 30m |
| Temora Shire DCP 2012, Rural Development (RU1) | Land zoned RU1 Primary Production (most of the shire). | 50m | 50m | not set by the DCP: ask the council | 50m |
What are the complying development setbacks for a house?
If you build a house with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 1.5m (2.1m at two storeys) | 5m (12m at two storeys) | 3m |
What if my block is on a corner?
Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1) sets a separate setback for a house from the second street, the side street of a corner block: 3m (Residential Development, s 3, Side and Rear Setbacks). The complying development figure for the second street is in the CDC table above.
Does a two storey house need bigger setbacks?
No. Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1) sets the same figures for a one or two storey house. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Temora Council approve a house closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Temora?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Temora Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.