How close to the boundary can a granny flat be in Temora?

Temora Council's main plan, Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1), asks a single storey granny flat for these setbacks: front 6m, side 0.9m and rear 3m.

In Temora the setbacks for a granny flat come from Temora Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the granny flat first.

Check your address

NSW addresses only. Free, and no sign up.

What setbacks does Temora Council's main plan set for a granny flat?

The table gives Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1)'s one and two storey figures and the clause each comes from. The plan covers this land: Land zoned R1 General Residential (Temora town, about 369 ha).

Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1): setbacks for a granny flat
SetbackOne storeyTwo storeysWhere in the plan
Front6m8mMulti-Unit Housing, s 3 Specific Development controls, Setbacks to boundaries (applied to dual occupancies and secondary dwellings by Residential Development, s 3, Dual Occupancies and Secondary Dwellings)
Side0.9m0.9mMulti-Unit Housing, s 3 Specific Development controls, Setbacks to boundaries (applied to dual occupancies and secondary dwellings by Residential Development, s 3, Dual Occupancies and Secondary Dwellings)
Rear3m3mMulti-Unit Housing, s 3 Specific Development controls, Setbacks to boundaries (applied to dual occupancies and secondary dwellings by Residential Development, s 3, Dual Occupancies and Secondary Dwellings)
Corner block, second street3m3mResidential Development, s 3, Side and Rear Setbacks (applied to dual occupancies and secondary dwellings by the same chapter's Dual Occupancies and Secondary Dwellings paragraph)

Which DCP applies to my block in Temora?

It depends on where the lot is. Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1) is Temora Council's main plan, and 4 other plans cover a granny flat on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.

Other plans in Temora that cover a granny flat
PlanWhere it appliesFrontSideRearSecond street
Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (RU5 villages and MU1)Land zoned RU5 Village (Ariah Park and Springdale, about 160 ha) and MU1 Mixed Use (Temora town, 34 ha).6m0.9m3m3m
Temora Shire DCP 2012, Large Lot Residential Development (R5)Land zoned R5 Large Lot Residential (about 432 ha around Temora town and 36 ha at Ariah Park), other than the Bundawarrah Estate Master Plan study area, which has its own plan with the same figures.30m30m30m30m
Temora Shire DCP 2012, Bundawarrah Estate Master Plan (R5)The Bundawarrah Estate Master Plan study area, "bordered by Evatt Street to the north, Narraburra Street to the east, Milvale Road/Loftus Street to the south and Bundawarrah Road to the west" (chapter s 3, Figure 1): R5 land on the east edge of Temora town.30m30m30m30m
Temora Shire DCP 2012, Rural Development (RU1)Land zoned RU1 Primary Production (most of the shire).50m50mnot set by the DCP: ask the council50m

What are the complying development setbacks for a granny flat?

If you build a granny flat with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.

Complying development (CDC) setbacks for a granny flat on three example lots
Example lotFrontSideRearCorner block, second street
450m² (15m wide, 30m deep)4.5m0.9m (1.5m at two storeys)3m2m
600m² (15m wide, 40m deep)4.5m0.9m (1.5m at two storeys)3m2m
1,000m² (20m wide, 50m deep)6.5m1.5m5m3m

What if my block is on a corner?

Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1) sets a separate setback for a granny flat from the second street, the side street of a corner block: 3m (Residential Development, s 3, Side and Rear Setbacks (applied to dual occupancies and secondary dwellings by the same chapter's Dual Occupancies and Secondary Dwellings paragraph)). The complying development figure for the second street is in the CDC table above.

Does a two storey granny flat need bigger setbacks?

Yes, under Temora Shire DCP 2012, Residential Development and Multi-Unit Housing (R1): the front setback goes from 6m to 8m. Under complying development, the two storey figures are in the CDC table above.

What else do people ask?

Can Temora Council approve a granny flat closer to the boundary?

It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.

Do these setbacks apply to a shed, pool or fence in Temora?

No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.

When were the setbacks on this page checked?

We last read Temora Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.

Where does this information come from?

These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.

What else can I check?

Check what applies to your block