What are Moree Plains Council's setbacks for a house, granny flat or duplex?
A setback is how far a home must sit from each boundary of its lot. In Moree Plains the setbacks for a house, a granny flat or a duplex come from Moree Plains Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page reads what we hold for each of the three.
It is a first look. Enter your address and the Site Checker opens at the setbacks for your lot, from the plan that covers it.
NSW addresses only. Free, and no sign up.
What are Moree Plains Council's setbacks for a house?
Moree Plains Council's main plan, Moree Plains DCP 2013, Chapter 3 Residential Development (Zone R1 General Residential), asks a single storey house for these setbacks: front the average of the neighbouring homes (6m where there are none); side 0.9m, plus 0.5m for every metre of wall above 3.5m; and rear 2.4m, plus 0.5m for every metre of wall above 3.5m.
House setbacks in Moree Plains gives the two storey figures, the clauses and every other plan that covers one.
What are Moree Plains Council's setbacks for a granny flat?
Moree Plains Council's main plan, Moree Plains DCP 2013, Chapter 3 Residential Development (Zone R1 General Residential), asks a single storey granny flat for these setbacks: front the average of the neighbouring homes (6m where there are none); side 0.9m, plus 0.5m for every metre of wall above 3.5m; and rear 2.4m, plus 0.5m for every metre of wall above 3.5m.
Granny flat setbacks in Moree Plains gives the two storey figures, the clauses and every other plan that covers one.
What are Moree Plains Council's setbacks for a duplex?
Moree Plains Council's main plan, Moree Plains DCP 2013, Chapter 3 Residential Development (Zone R1 General Residential), asks a single storey duplex for these setbacks: front the average of the neighbouring homes (6m where there are none); side 0.9m, plus 0.5m for every metre of wall above 3.5m; and rear 2.4m, plus 0.5m for every metre of wall above 3.5m.
Duplex setbacks in Moree Plains gives the two storey figures, the clauses and every other plan that covers one.
Which DCP covers my block in Moree Plains?
It depends on the lot: we hold 6 plans with setbacks for homes in Moree Plains Council, and Moree Plains DCP 2013, Chapter 3 Residential Development (Zone R1 General Residential) is the main one. The others cover particular land, such as precincts, estates, rural land or former council areas. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot.
| Plan | Where it applies | Homes it covers |
|---|---|---|
| Moree Plains DCP 2013, Chapter 3 Residential Development (Zone R1 General Residential) | Main plan. Land zoned R1 General Residential. | house, granny flat, duplex |
| Moree Plains DCP 2013, Chapter 3 Residential Development (Zone RU5 Village) | Land zoned RU5 Village (the shire's villages). | house, granny flat, duplex |
| Moree Plains DCP 2013, Chapter 3 Residential Development (Zone R2 Low Density Residential) | Land zoned R2 Low Density Residential. | house, granny flat, duplex |
| Moree Plains DCP 2013, Chapter 3 Residential Development (Zone R5 Large Lot Residential) | Land zoned R5 Large Lot Residential. | house, granny flat, duplex |
| Moree Plains DCP 2013, Chapter 9 Rural Development, Rural Dwellings (Zone RU1) | Land zoned RU1 Primary Production. | house, granny flat, duplex |
| Moree Plains DCP 2013, Chapter 9 Rural Development, Rural Dwellings (Zone RU4) | Land zoned RU4 Primary Production Small Lots. | house, duplex |
Do Moree Plains Council's setbacks apply to complying development?
No. A home approved with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, follows the state codes' setbacks instead of the council's. On a 600m² (15m wide, 40m deep) lot, for example, the Site Checker reads the complying development setbacks for a house as front 4.5m, side 0.9m (1.5m at two storeys) and rear 3m (8m at two storeys).
The council's plan applies when you lodge a development application. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more.
What setbacks apply on a corner block in Moree Plains?
Moree Plains DCP 2013, Chapter 3 Residential Development (Zone R1 General Residential) sets a separate setback for a house from the second street, the side street of a corner block: 4m (Chapter 3 Residential Development, Setbacks, Acceptable Solution 1, Table 3.2). The front setback still applies to the main street. Under complying development the code sets its own second street figure by lot size.
What else do people ask?
Can Moree Plains Council approve a smaller setback?
It can, through a development application. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more.
Do Moree Plains setbacks apply to sheds, pools and fences?
Not the ones on this page. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were Moree Plains Council's setbacks checked?
We last read Moree Plains Council's plans on 12 November 2026. Each plan links to the council's own document, so you can check a figure against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.