What are Hunter's Hill Council's setbacks for a house, granny flat or duplex?
A setback is how far a home must sit from each boundary of its lot. In Hunter's Hill the setbacks for a house, a granny flat or a duplex come from Hunter's Hill Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page reads what we hold for each of the three.
It is a first look. Enter your address and the Site Checker opens at the setbacks for your lot, from the plan that covers it.
NSW addresses only. Free, and no sign up.
What are Hunter's Hill Council's setbacks for a house?
Hunter's Hill Council's main plan, Hunters Hill Consolidated DCP 2013, Part Three (Ch 3.3 Dwelling Houses, Secondary Dwellings; Ch 3.4 Multi-unit Residential), asks a single storey house for these setbacks: front the average of the neighbouring homes, side 1.5m and rear 6m.
House setbacks in Hunter's Hill gives the two storey figures, the clauses and every other plan that covers one.
What are Hunter's Hill Council's setbacks for a granny flat?
Hunter's Hill Council's main plan, Hunters Hill Consolidated DCP 2013, Part Three (Ch 3.3 Dwelling Houses, Secondary Dwellings; Ch 3.4 Multi-unit Residential), asks a single storey granny flat for these setbacks: front the average of the neighbouring homes, side 1.5m and rear 6m.
Granny flat setbacks in Hunter's Hill gives the two storey figures, the clauses and every other plan that covers one.
What are Hunter's Hill Council's setbacks for a duplex?
Hunter's Hill Council's main plan, Hunters Hill Consolidated DCP 2013, Part Three (Ch 3.3 Dwelling Houses, Secondary Dwellings; Ch 3.4 Multi-unit Residential), asks a single storey duplex for these setbacks: front the average of the neighbouring homes; side 1.5m, plus 0.33m for every metre of wall above 4.5m; and rear 6m.
Duplex setbacks in Hunter's Hill gives the two storey figures, the clauses and every other plan that covers one.
Which DCP covers my block in Hunter's Hill?
It depends on the lot: we hold 3 plans with setbacks for homes in Hunter's Hill Council, and Hunters Hill Consolidated DCP 2013, Part Three (Ch 3.3 Dwelling Houses, Secondary Dwellings; Ch 3.4 Multi-unit Residential) is the main one. The others cover particular land, such as precincts, estates, rural land or former council areas. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot.
| Plan | Where it applies | Homes it covers |
|---|---|---|
| Hunters Hill Consolidated DCP 2013, Part Three (Ch 3.3 Dwelling Houses, Secondary Dwellings; Ch 3.4 Multi-unit Residential) | Main plan. R2 Low Density Residential and R3 Medium Density Residential land in Hunters Hill, outside the Ryde Road Precinct and the Barons Crescent bushland lots. | house, granny flat, duplex |
| Hunters Hill Consolidated DCP 2013, s 3.4.7 Special Controls for Ryde Road (Ryde Road Precinct) | The Ryde Road Precinct. | house, granny flat, duplex |
| Hunters Hill Consolidated DCP 2013, Ch 3.2 Bushland Localities (Barons Crescent) | Ch 3.2 s 3.2.1: "This chapter applies to residential developments on properties in Barons Crescent that adjoin Buffalo Creek Reserve and/or Boronia Park Reserve." Traced as the 35 R2 lots of the Barons Crescent addressed properties whose land shares a boundary with the C2 bushland reserve along Buffalo Creek and the Lane Cove River (the C2 lots 7354//DP1156134, 7028//DP93647 and A//DP403273). | house, granny flat, duplex |
Do Hunter's Hill Council's setbacks apply to complying development?
No. A home approved with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, follows the state codes' setbacks instead of the council's. On a 600m² (15m wide, 40m deep) lot, for example, the Site Checker reads the complying development setbacks for a house as front 4.5m, side 0.9m (1.5m at two storeys) and rear 3m (8m at two storeys).
The council's plan applies when you lodge a development application. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more.
What setbacks apply on a corner block in Hunter's Hill?
Hunters Hill Consolidated DCP 2013, Part Three (Ch 3.3 Dwelling Houses, Secondary Dwellings; Ch 3.4 Multi-unit Residential) sets a separate setback for a house from the second street, the side street of a corner block: 1.5m (Hunters Hill Consolidated DCP 2013, Part Three, Ch 3.3 Dwelling Houses, Secondary Dwellings & Ancillary Works, s 3.3.3 Front, Side & Rear Setbacks, Front boundary setbacks, Notes). The front setback still applies to the main street. Under complying development the code sets its own second street figure by lot size.
What else do people ask?
Can Hunter's Hill Council approve a smaller setback?
It can, through a development application. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more.
Do Hunter's Hill setbacks apply to sheds, pools and fences?
Not the ones on this page. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were Hunter's Hill Council's setbacks checked?
We last read Hunter's Hill Council's plans on 12 November 2026. Each plan links to the council's own document, so you can check a figure against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.