How close to the boundary can a granny flat be in Hunter's Hill?
Hunter's Hill Council's main plan, Hunters Hill Consolidated DCP 2013, Part Three (Ch 3.3 Dwelling Houses, Secondary Dwellings; Ch 3.4 Multi-unit Residential), asks a single storey granny flat for these setbacks: front the average of the neighbouring homes, side 1.5m and rear 6m.
In Hunter's Hill the setbacks for a granny flat come from Hunter's Hill Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the granny flat first.
NSW addresses only. Free, and no sign up.
What setbacks does Hunter's Hill Council's main plan set for a granny flat?
The table gives Hunters Hill Consolidated DCP 2013, Part Three (Ch 3.3 Dwelling Houses, Secondary Dwellings; Ch 3.4 Multi-unit Residential)'s one and two storey figures and the clause each comes from. The plan covers this land: R2 Low Density Residential and R3 Medium Density Residential land in Hunters Hill, outside the Ryde Road Precinct and the Barons Crescent bushland lots.
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | the average of the neighbouring homes | the average of the neighbouring homes | Hunters Hill Consolidated DCP 2013, Part Three, Ch 3.3 Dwelling Houses, Secondary Dwellings & Ancillary Works, s 3.3.3 Front, Side & Rear Setbacks, Front boundary setbacks (a) |
| Side | 1.5m | 1.5m | Hunters Hill Consolidated DCP 2013, Part Three, Ch 3.3 Dwelling Houses, Secondary Dwellings & Ancillary Works, s 3.3.3 Front, Side & Rear Setbacks, Side boundary setbacks (a) |
| Rear | 6m | 6m | Hunters Hill Consolidated DCP 2013, Part Three, Ch 3.3 Dwelling Houses, Secondary Dwellings & Ancillary Works, s 3.3.3 Front, Side & Rear Setbacks, Rear boundary setbacks (a) to (c) |
| Corner block, second street | 1.5m | 1.5m | Hunters Hill Consolidated DCP 2013, Part Three, Ch 3.3 Dwelling Houses, Secondary Dwellings & Ancillary Works, s 3.3.3 Front, Side & Rear Setbacks, Front boundary setbacks, Notes |
Which DCP applies to my block in Hunter's Hill?
It depends on where the lot is. Hunters Hill Consolidated DCP 2013, Part Three (Ch 3.3 Dwelling Houses, Secondary Dwellings; Ch 3.4 Multi-unit Residential) is Hunter's Hill Council's main plan, and 2 other plans cover a granny flat on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Hunters Hill Consolidated DCP 2013, s 3.4.7 Special Controls for Ryde Road (Ryde Road Precinct) | The Ryde Road Precinct. | the average of the neighbouring homes | 1.5m | 6m | 1.5m |
| Hunters Hill Consolidated DCP 2013, Ch 3.2 Bushland Localities (Barons Crescent) | Ch 3.2 s 3.2.1: "This chapter applies to residential developments on properties in Barons Crescent that adjoin Buffalo Creek Reserve and/or Boronia Park Reserve." Traced as the 35 R2 lots of the Barons Crescent addressed properties whose land shares a boundary with the C2 bushland reserve along Buffalo Creek and the Lane Cove River (the C2 lots 7354//DP1156134, 7028//DP93647 and A//DP403273). | the average of the neighbouring homes | 1.5m | at least 6m, or the street's established building line where that is further back | 1.5m |
What are the complying development setbacks for a granny flat?
If you build a granny flat with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 1.5m | 5m | 3m |
What if my block is on a corner?
Hunters Hill Consolidated DCP 2013, Part Three (Ch 3.3 Dwelling Houses, Secondary Dwellings; Ch 3.4 Multi-unit Residential) sets a separate setback for a granny flat from the second street, the side street of a corner block: 1.5m (Hunters Hill Consolidated DCP 2013, Part Three, Ch 3.3 Dwelling Houses, Secondary Dwellings & Ancillary Works, s 3.3.3 Front, Side & Rear Setbacks, Front boundary setbacks, Notes). It measures the front setback from the street the home is addressed to. The complying development figure for the second street is in the CDC table above.
Does a two storey granny flat need bigger setbacks?
No. Hunters Hill Consolidated DCP 2013, Part Three (Ch 3.3 Dwelling Houses, Secondary Dwellings; Ch 3.4 Multi-unit Residential) sets the same figures for a one or two storey granny flat. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Hunter's Hill Council approve a granny flat closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Hunter's Hill?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Hunter's Hill Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.