How close to the boundary can a granny flat be in Singleton?
Singleton Council's main plan, Singleton DCP 2014, ss 2.10 and 2.12 (R1 and R2), asks a single storey granny flat for these setbacks: front 6m on lots up to 24.99m wide, 5.5m on wider lots; side 0.9m; and rear 3m, plus 1m for every metre of wall above 5m.
In Singleton the setbacks for a granny flat come from Singleton Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the granny flat first.
NSW addresses only. Free, and no sign up.
What setbacks does Singleton Council's main plan set for a granny flat?
The table gives Singleton DCP 2014, ss 2.10 and 2.12 (R1 and R2)'s one and two storey figures and the clause each comes from. The plan covers this land: Land in Zone R1 General Residential and Zone R2 Low Density Residential across the Singleton LGA (s 1.4: the DCP applies to the land on its Land Application Map, which shows the LGA as included land), outside the Huntlee New Town site.
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | 6m on lots up to 24.99m wide, 5.5m on wider lots | 6m on lots up to 24.99m wide, 5.5m on wider lots | Singleton DCP 2014, s 2.10(3), Table 2.10A; s 2.7(3) and (5)(c) |
| Side | 0.9m | 1.5m for walls over 5 m high facing the boundary | Singleton DCP 2014, s 2.12(3) |
| Rear | 3m, plus 1m for every metre of wall above 5m | 3m, plus 1m for every metre of wall above 5m | Singleton DCP 2014, s 2.12(4) |
| Corner block, second street | 5.5m | 5.5m | Singleton DCP 2014, s 2.10(1)(c), (3), (4), Table 2.10A, Note 1 |
Which DCP applies to my block in Singleton?
It depends on where the lot is. Singleton DCP 2014, ss 2.10 and 2.12 (R1 and R2) is Singleton Council's main plan, and 2 other plans cover a granny flat on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Singleton DCP 2014, ss 2.10 and 2.12 (R5 Large Lot Residential) | Land in Zone R5 Large Lot Residential, including the R5 land at Huntlee (the Huntlee DCP covers only R1, R2 and B4 land). | 15m | 5m | 10m | 15m |
| Huntlee DCP 2013, Part 5 Residential Development | Land in Zone R1 General Residential and R2 Low Density Residential within the Huntlee New Town site in the Singleton LGA (south-west of Branxton, south of the Main Northern rail line). | 3.5m on lots up to 250m², 4.5m on lots up to 800m², 8m on larger lots | 0m on lots up to 250m², 1m on lots up to 800m², 1.5m on larger lots to one side, 0m on lots up to 250m², 1m on lots up to 800m², 4.5m on larger lots to the other | 3m on lots up to 250m², 4m on lots up to 800m², 6m on larger lots | 1m on lots up to 250m², 1m on lots up to 800m², 3m on larger lots |
What are the complying development setbacks for a granny flat?
If you build a granny flat with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 1.5m | 5m | 3m |
What if my block is on a corner?
Singleton DCP 2014, ss 2.10 and 2.12 (R1 and R2) sets a separate setback for a granny flat from the second street, the side street of a corner block: 5.5m (Singleton DCP 2014, s 2.10(1)(c), (3), (4), Table 2.10A, Note 1). The complying development figure for the second street is in the CDC table above.
Does a two storey granny flat need bigger setbacks?
Yes, under Singleton DCP 2014, ss 2.10 and 2.12 (R1 and R2): the side setback goes from 0.9m to 1.5m for walls over 5 m high facing the boundary. The rear setback also grows as the wall gets taller. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Singleton Council approve a granny flat closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Singleton?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Singleton Council's plans on 11 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.