What are Georges River Council's setbacks for a house, granny flat or duplex?
A setback is how far a home must sit from each boundary of its lot. In Georges River the setbacks for a house, a granny flat or a duplex come from Georges River Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page reads what we hold for each of the three.
It is a first look. Enter your address and the Site Checker opens at the setbacks for your lot, from the plan that covers it.
NSW addresses only. Free, and no sign up.
What are Georges River Council's setbacks for a house?
Georges River Council's main plan, Georges River DCP 2021, Part 6.1 (Low Density Residential), asks a single storey house for these setbacks: front at least 4.5m, or the street's established building line where that is further back; side 0.9m on lots up to 12.5m wide, 1.2m on wider lots; and rear 15% of the lot depth, and at least 6m.
House setbacks in Georges River gives the two storey figures, the clauses and every other plan that covers one.
What are Georges River Council's setbacks for a granny flat?
Georges River Council's main plan, Georges River DCP 2021, Part 6.1 (Low Density Residential), asks a single storey granny flat for these setbacks: front at least 4.5m, or the street's established building line where that is further back; side 1.5m; and rear 1.5m.
Granny flat setbacks in Georges River gives the two storey figures, the clauses and every other plan that covers one.
What are Georges River Council's setbacks for a duplex?
Georges River Council's main plan, Georges River DCP 2021, Part 6.1 (Low Density Residential), asks a single storey duplex for these setbacks: front at least 4.5m, or the street's established building line where that is further back; side 1.2m; and rear 15% of the lot depth, and at least 6m.
Duplex setbacks in Georges River gives the two storey figures, the clauses and every other plan that covers one.
Which DCP covers my block in Georges River?
It depends on the lot: we hold 4 plans with setbacks for homes in Georges River Council, and Georges River DCP 2021, Part 6.1 (Low Density Residential) is the main one. The others cover particular land, such as precincts, estates, rural land or former council areas. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot.
| Plan | Where it applies | Homes it covers |
|---|---|---|
| Georges River DCP 2021, Part 6.1 (Low Density Residential) | Main plan. All land in the Georges River LGA (GRDCP Part 1 s 1.8) outside the Foreshore Scenic Protection Area. | house, granny flat, duplex |
| Georges River DCP 2021, Parts 6.1 and 6.5 (Foreshore Scenic Protection Area) | Land in the Foreshore Scenic Protection Area under GRLEP 2021 cl 6.6. | house, granny flat, duplex |
| Georges River DCP 2021, Part 6.1, s 6.1.4 Narrow Lot Housing: Bellevue Estate | Nominated narrow lot sites within Bellevue Estate, bounded by Bellevue Parade, Russell Lane, Buraneer Close and First Avenue (s 6.1.4, Figure 11). | house, granny flat, duplex |
| Georges River DCP 2021, Part 6.1, s 6.1.5 Narrow Lot Housing: Kemps Estate, Mortdale | Dwelling houses within Kemps Estate, Mortdale: Station, Universal, Broughton, Crump and Kemp's Streets, including parts of Morts and Boundary Roads (s 6.1.5 Figure 13; Appendix 7). | house, granny flat, duplex |
Do Georges River Council's setbacks apply to complying development?
No. A home approved with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, follows the state codes' setbacks instead of the council's. On a 600m² (15m wide, 40m deep) lot, for example, the Site Checker reads the complying development setbacks for a house as front 4.5m, side 0.9m (1.5m at two storeys) and rear 3m (8m at two storeys).
The council's plan applies when you lodge a development application. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more.
What setbacks apply on a corner block in Georges River?
Georges River DCP 2021, Part 6.1 (Low Density Residential) sets a separate setback for a house from the second street, the side street of a corner block: 1.2m on lots up to 14.99m wide, 2m on wider lots (GRDCP 2021, Part 6.1, s 6.1.2.3 Setbacks, Front Setbacks, control 3). The front setback still applies to the main street. Under complying development the code sets its own second street figure by lot size.
What else do people ask?
Can Georges River Council approve a smaller setback?
It can, through a development application. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more.
Do Georges River setbacks apply to sheds, pools and fences?
Not the ones on this page. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were Georges River Council's setbacks checked?
We last read Georges River Council's plans on 11 November 2026. Each plan links to the council's own document, so you can check a figure against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.