How close to the boundary can a granny flat be in Georges River?
Georges River Council's main plan, Georges River DCP 2021, Part 6.1 (Low Density Residential), asks a single storey granny flat for these setbacks: front at least 4.5m, or the street's established building line where that is further back; side 1.5m; and rear 1.5m.
In Georges River the setbacks for a granny flat come from Georges River Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the granny flat first.
NSW addresses only. Free, and no sign up.
What setbacks does Georges River Council's main plan set for a granny flat?
The table gives Georges River DCP 2021, Part 6.1 (Low Density Residential)'s one and two storey figures and the clause each comes from. The plan covers this land: All land in the Georges River LGA (GRDCP Part 1 s 1.8) outside the Foreshore Scenic Protection Area.
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | at least 4.5m, or the street's established building line where that is further back | at least 4.5m, or the street's established building line where that is further back | GRDCP 2021, Part 6.1, s 6.1.2.12 Secondary Dwellings, controls 1 and 7; s 6.1.2.3 control 1 |
| Side | 1.5m | 0.9m on lots up to 12.5m wide, 1.2m on wider lots | GRDCP 2021, Part 6.1, s 6.1.2.12 Secondary Dwellings, controls 1, 5 and 6; s 6.1.2.3 control 5 |
| Rear | 1.5m | 15% of the lot depth, and at least 6m | GRDCP 2021, Part 6.1, s 6.1.2.12 Secondary Dwellings, controls 1, 5 and 6; s 6.1.2.3 control 4 |
| Corner block, second street | 1.2m on lots up to 14.99m wide, 2m on wider lots | 1.2m on lots up to 14.99m wide, 2m on wider lots | GRDCP 2021, Part 6.1, s 6.1.2.12 Secondary Dwellings, control 7; s 6.1.2.3 control 3 |
Which DCP applies to my block in Georges River?
It depends on where the lot is. Georges River DCP 2021, Part 6.1 (Low Density Residential) is Georges River Council's main plan, and 3 other plans cover a granny flat on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Georges River DCP 2021, Parts 6.1 and 6.5 (Foreshore Scenic Protection Area) | Land in the Foreshore Scenic Protection Area under GRLEP 2021 cl 6.6. | at least 4.5m, or the street's established building line where that is further back | 1.5m | 1.5m | 1.2m on lots up to 14.99m wide, 2m on wider lots |
| Georges River DCP 2021, Part 6.1, s 6.1.4 Narrow Lot Housing: Bellevue Estate | Nominated narrow lot sites within Bellevue Estate, bounded by Bellevue Parade, Russell Lane, Buraneer Close and First Avenue (s 6.1.4, Figure 11). | 5.5m | 1.5m | 1.5m | 1.2m on lots up to 14.99m wide, 2m on wider lots |
| Georges River DCP 2021, Part 6.1, s 6.1.5 Narrow Lot Housing: Kemps Estate, Mortdale | Dwelling houses within Kemps Estate, Mortdale: Station, Universal, Broughton, Crump and Kemp's Streets, including parts of Morts and Boundary Roads (s 6.1.5 Figure 13; Appendix 7). | 4.5m on lots up to 6.49m wide, 5.5m on wider lots | 1.5m | 1.5m | 1.2m on lots up to 14.99m wide, 2m on wider lots |
What are the complying development setbacks for a granny flat?
If you build a granny flat with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 1.5m | 5m | 3m |
What if my block is on a corner?
Georges River DCP 2021, Part 6.1 (Low Density Residential) sets a separate setback for a granny flat from the second street, the side street of a corner block: 1.2m on lots up to 14.99m wide, 2m on wider lots (GRDCP 2021, Part 6.1, s 6.1.2.12 Secondary Dwellings, control 7; s 6.1.2.3 control 3). The complying development figure for the second street is in the CDC table above.
Does a two storey granny flat need bigger setbacks?
Yes, under Georges River DCP 2021, Part 6.1 (Low Density Residential): the side setback goes from 1.5m to 0.9m on lots up to 12.5m wide, 1.2m on wider lots; the rear setback goes from 1.5m to 15% of the lot depth, and at least 6m. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Georges River Council approve a granny flat closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Georges River?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Georges River Council's plans on 11 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.