What are Byron Council's setbacks for a house, granny flat or duplex?
A setback is how far a home must sit from each boundary of its lot. In Byron the setbacks for a house, a granny flat or a duplex come from Byron Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page reads what we hold for each of the three.
It is a first look. Enter your address and the Site Checker opens at the setbacks for your lot, from the plan that covers it.
NSW addresses only. Free, and no sign up.
What are Byron Council's setbacks for a house?
Byron Council's main plan, Byron DCP 2014, Chapter D1 Residential Accommodation in Urban, Village and Special Purpose Zones, asks a single storey house for these setbacks: front 4.5m; side inside a plane rising at 45° from 1.8m above the boundary, and at least 0.9m; and rear inside a plane rising at 45° from 1.8m above the boundary, and at least 0.9m.
House setbacks in Byron gives the two storey figures, the clauses and every other plan that covers one.
What are Byron Council's setbacks for a granny flat?
Byron Council's main plan, Byron DCP 2014, Chapter D1 Residential Accommodation in Urban, Village and Special Purpose Zones, asks a single storey granny flat for these setbacks: front 4.5m; side inside a plane rising at 45° from 1.8m above the boundary, and at least 1.5m; and rear inside a plane rising at 45° from 1.8m above the boundary, and at least 1.5m.
Granny flat setbacks in Byron gives the two storey figures, the clauses and every other plan that covers one.
What are Byron Council's setbacks for a duplex?
Byron Council's main plan, Byron DCP 2014, Chapter D1 Residential Accommodation in Urban, Village and Special Purpose Zones, asks a single storey duplex for these setbacks: front 4.5m; side inside a plane rising at 45° from 1.8m above the boundary, and at least 1.5m; and rear inside a plane rising at 45° from 1.8m above the boundary, and at least 1.5m.
Duplex setbacks in Byron gives the two storey figures, the clauses and every other plan that covers one.
Which DCP covers my block in Byron?
It depends on the lot: we hold 11 plans with setbacks for homes in Byron Council, and Byron DCP 2014, Chapter D1 Residential Accommodation in Urban, Village and Special Purpose Zones is the main one. The others cover particular land, such as precincts, estates, rural land or former council areas. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot.
| Plan | Where it applies | Homes it covers |
|---|---|---|
| Byron DCP 2014, Chapter D1 Residential Accommodation in Urban, Village and Special Purpose Zones | Main plan. R2, R3 and R5 land under Byron LEP 2014. | house, granny flat, duplex |
| Byron DCP 2014, Chapter D1 (RU5 Village) | RU5 Village land under Byron LEP 2014. | house, granny flat, duplex |
| Byron DCP 2014, Chapter D1 (MU1 Mixed Use) | MU1 Mixed Use land under Byron LEP 2014 (the former B4 Mixed Use zone that D1.1.2 lists). | house, duplex |
| Byron DCP 2014, Chapter E8 West Byron Urban Release Area (R2) | R2 land on the West Byron Bay site, Ewingsdale Road, Byron Bay. E8.3: the chapter applies to land identified as "West Byron Bay site" on the Urban Release Area Map; the Planning Portal Urban Release Area layer carries that outline (one 110 ha polygon labelled "West Byron Bay site"). | house, granny flat, duplex |
| Byron DCP 2014, Chapter E8 West Byron Urban Release Area (R3) | R3 land on the West Byron Bay site, Ewingsdale Road, Byron Bay. E8.3: the chapter applies to land identified as "West Byron Bay site" on the Urban Release Area Map; the Planning Portal Urban Release Area layer carries that outline (one 110 ha polygon labelled "West Byron Bay site"). | house, granny flat, duplex |
| Byron DCP 2014, Chapter D2 Residential Accommodation and Ancillary Development in Rural Zones | RU1 Primary Production and RU2 Rural Landscape land under Byron LEP 2014. | house, granny flat, duplex |
| Byron DCP 2014, Chapter C1 Non-Indigenous Heritage, Eureka Village Landscape Conservation Area (with Chapter D2) | RU1 and RU2 land inside the Eureka Village Landscape Conservation Area (Byron LEP 2014 Schedule 5, C006). | house, granny flat, duplex |
| Byron DCP 2014, Chapter E12 Gulgan Village | RU2 land in Gulgan Village, The Saddle Road and Gulgan Road, Brunswick Heads (Lot 32 DP1018929, Lot 2 DP1159910, Lot 1 DP441896, Lot 1 DP584730). | house, granny flat, duplex |
Show 3 more plans
| Plan | Where it applies | Homes it covers |
|---|---|---|
| Byron DCP 2010, Chapter 1 Part C Residential Development (deferred matter land, Byron LEP 1988 zone 2(a)) | Land shown as "Deferred matter" (DM) on the Byron LEP 2014 Land Zoning Map, where Byron LEP 1988 still applies (LEP 2014 cl 1.3(1A)), and which is zoned 2(a) Residential under Byron LEP 1988 (about 23.5 ha; in 2026 one 30 ha development lot, 13//DP1251383, and three small lots). | house, granny flat, duplex |
| Byron DCP 2010, Chapter 1 Part C Residential Development (deferred matter land, Byron LEP 1988 zone 7(f2)) | Land shown as "Deferred matter" (DM) on the Byron LEP 2014 Land Zoning Map, where Byron LEP 1988 still applies (LEP 2014 cl 1.3(1A)), and which is zoned 7(f2) Urban Coastal Lands under Byron LEP 1988 (about 61 ha, about 505 lots: New Brighton, Belongil and Suffolk Park beachfront). | house, duplex |
| Byron DCP 2010, Chapter 1 Part C Residential Development (deferred matter land, Byron LEP 1988 rural and 7(c)/7(d) zones) | Land shown as "Deferred matter" (DM) on the Byron LEP 2014 Land Zoning Map, where Byron LEP 1988 still applies (LEP 2014 cl 1.3(1A)), and which is zoned 1(a), 1(b1), 1(b2), 1(c1), 1(c2), 1(d), 7(c) Water Catchment or 7(d) Scenic/Escarpment under Byron LEP 1988 (about 2,050 ha, nearly all of it 7(d) hinterland). | house, duplex |
Do Byron Council's setbacks apply to complying development?
No. A home approved with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, follows the state codes' setbacks instead of the council's. On a 600m² (15m wide, 40m deep) lot, for example, the Site Checker reads the complying development setbacks for a house as front 4.5m, side 0.9m (1.5m at two storeys) and rear 3m (8m at two storeys).
The council's plan applies when you lodge a development application. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more.
What setbacks apply on a corner block in Byron?
Byron DCP 2014, Chapter D1 Residential Accommodation in Urban, Village and Special Purpose Zones sets a separate setback for a house from the second street, the side street of a corner block: inside a plane rising at 45° from 1.8m above the boundary, and at least 3m (Byron DCP 2014, Chapter D1, s D1.2.2 Prescriptive Measure 1 d); Byron DCP 2014, Chapter D1, s D1.2.1 Prescriptive Measure 1; s D1.2.2 Performance Criterion 5; Part A Dictionary, Building height plane). The front setback still applies to the main street. Under complying development the code sets its own second street figure by lot size.
What else do people ask?
Can Byron Council approve a smaller setback?
It can, through a development application. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more.
Do Byron setbacks apply to sheds, pools and fences?
Not the ones on this page. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were Byron Council's setbacks checked?
We last read Byron Council's plans on 12 November 2026. Each plan links to the council's own document, so you can check a figure against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.