How close to the boundary can a house be in Parkes?
Parkes Council's main plan, Parkes Shire DCP 2021, Parts C.2 and C.3 (urban dwellings and medium density), asks a single storey house for these setbacks: front the average of the neighbouring homes (4.5m where there are none) on lots up to 599.99m², the average of the neighbouring homes (6m where there are none) on larger lots; side 0.9m; and rear 3m on lots up to 599.99m², 5m on larger lots.
In Parkes the setbacks for a house come from Parkes Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the house first.
NSW addresses only. Free, and no sign up.
What setbacks does Parkes Council's main plan set for a house?
The table gives Parkes Shire DCP 2021, Parts C.2 and C.3 (urban dwellings and medium density)'s one and two storey figures and the clause each comes from. The plan covers this land: Land zoned R1 General Residential, RU5 Village and MU1 Mixed Use under Parkes LEP 2012.
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | the average of the neighbouring homes (4.5m where there are none) on lots up to 599.99m², the average of the neighbouring homes (6m where there are none) on larger lots | not set by the DCP: ask the council | Parkes DCP 2021, Part C.2.4 Setbacks Standard Lots, standard a. table |
| Side | 0.9m | 1.5m | Parkes DCP 2021, Part C.2.4 Setbacks Standard Lots, standard a. table |
| Rear | 3m on lots up to 599.99m², 5m on larger lots | 5m on lots up to 599.99m², 8m on larger lots | Parkes DCP 2021, Part C.2.4 Setbacks Standard Lots, standard a. table |
| Corner block, second street | 3m | 3m | Parkes DCP 2021, Part C.2.4 Setbacks Corner Lots, standard a. table |
Which DCP applies to my block in Parkes?
It depends on where the lot is. Parkes Shire DCP 2021, Parts C.2 and C.3 (urban dwellings and medium density) is Parkes Council's main plan, and 4 other plans cover a house on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Parkes Shire DCP 2021, Part C.6 (rural dwellings, RU1) | Land zoned RU1 Primary Production under Parkes LEP 2012 (Part C.6.1). | 20m | not set by the DCP: ask the council | not set by the DCP: ask the council | 20m |
| Parkes Shire DCP 2021, Part C.5.4 (R5 Zone 4,000m2 Lot Size Area) | Land zoned R5 Large Lot Residential that the Parkes LEP 2012 Lot Size Map puts in the 4,000 m2 minimum lot size (46.6 ha of R5). | the average of the neighbouring homes (15m where there are none) | 5m | 10m | 10m |
| Parkes Shire DCP 2021, Part C.5.4 (R5 Zone 1ha Lot Size Areas) | Land zoned R5 Large Lot Residential that the Parkes LEP 2012 Lot Size Map puts in the 1 ha minimum lot size (658.2 ha of R5). | the average of the neighbouring homes (20m where there are none) | 5m | 10m | 10m |
| Parkes Shire DCP 2021, Part C.5.4 (R5 Zone 4ha Lot Size Areas) | Land zoned R5 Large Lot Residential that the Parkes LEP 2012 Lot Size Map puts in the 4 ha minimum lot size (2,087.0 ha of R5). | the average of the neighbouring homes (20m where there are none) | 10m | 20m | 10m |
What are the complying development setbacks for a house?
If you build a house with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 1.5m (2.1m at two storeys) | 5m (12m at two storeys) | 3m |
What if my block is on a corner?
Parkes Shire DCP 2021, Parts C.2 and C.3 (urban dwellings and medium density) sets a separate setback for a house from the second street, the side street of a corner block: 3m (Parkes DCP 2021, Part C.2.4 Setbacks Corner Lots, standard a. table). The complying development figure for the second street is in the CDC table above.
Does a two storey house need bigger setbacks?
Yes, under Parkes Shire DCP 2021, Parts C.2 and C.3 (urban dwellings and medium density): the front setback goes from the average of the neighbouring homes (4.5m where there are none) on lots up to 599.99m², the average of the neighbouring homes (6m where there are none) on larger lots to not set by the DCP: ask the council; the side setback goes from 0.9m to 1.5m; the rear setback goes from 3m on lots up to 599.99m², 5m on larger lots to 5m on lots up to 599.99m², 8m on larger lots. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Parkes Council approve a house closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Parkes?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Parkes Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.