How close to the boundary can a granny flat be in Randwick?
Randwick Council's main plan, Randwick DCP, Part C1 Low Density Residential (R2), asks a single storey granny flat for these setbacks: front the average of the neighbouring homes (6m where there are none) and rear 3m. It does not set a side setback: ask the council.
In Randwick the setbacks for a granny flat come from Randwick Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the granny flat first.
NSW addresses only. Free, and no sign up.
What setbacks does Randwick Council's main plan set for a granny flat?
The table gives Randwick DCP, Part C1 Low Density Residential (R2)'s one and two storey figures and the clause each comes from. The plan covers this land: Zone R2 Low Density Residential land in Randwick.
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | the average of the neighbouring homes (6m where there are none) | the average of the neighbouring homes (6m where there are none) | Part C1, s 3.3.1 Front setbacks, control a) |
| Side | not set by the DCP: ask the council | not set by the DCP: ask the council | None |
| Rear | 3m | 3m | Part C1, s 8.8 Secondary dwelling, control c) |
| Corner block, second street | 0.9m on lots up to 6.99m wide, 1.5m on wider lots | 0.9m on lots up to 6.99m wide, 1.5m on wider lots | Part C1, s 3.3.1 Front setbacks, control b) |
Which DCP applies to my block in Randwick?
It depends on where the lot is. Randwick DCP, Part C1 Low Density Residential (R2) is Randwick Council's main plan, and 7 other plans cover a granny flat on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Randwick DCP, Part C1 Low Density Residential (R1, R3) | Zone R1 General Residential and R3 Medium Density Residential land in Randwick outside the site specific parts traced below (Defence Site, Newmarket Green, Prince Henry, Little Bay Cove). | the average of the neighbouring homes (6m where there are none) | not set by the DCP: ask the council | 3m | 0.9m on lots up to 6.99m wide, 1.5m on wider lots |
| Randwick DCP, Part D8 Defence Site (Bundock and Avoca Streets, Kingsford) | The Defence Site between Bundock Street, Avoca Street and Holmes Street, Kingsford (D8 Figure 1). | 3m | not set by the DCP: ask the council | 6m | not set |
| Randwick DCP, Part D12 Newmarket Green | The Newmarket Green key site, "generally bounded by Barker, Jane, Young, Middle and Botany Streets" (D12 s 1.2, Figure 1). | 3m | not set by the DCP: ask the council | 3m | 3m |
| Randwick DCP, Part D13 Little Bay Cove | The Little Bay Cove site at 1406-1408 Anzac Parade, Little Bay, between Cawood Avenue, Anzac Parade, Gubbuteh Road and The Coast golf course (D13 Figure 1). | 3m | not set by the DCP: ask the council | 3m | not set |
| Randwick DCP, Part D11 Prince Henry Site, Precinct P4 | Precinct P4 of the Prince Henry site: the detached dwelling lots D46 to D68 east of Ewing Avenue, between the Coast Hospital Memorial Park, Harvey Street and the golf course buffer (D11 s 7.4, Figure 14). | 3m | not set by the DCP: ask the council | 8m | 4.5m |
| Randwick DCP, Part D11 Prince Henry Site, Little Bay (other precincts) | The Prince Henry site at Little Bay outside Precinct P4: precincts P1, P2, P3, P5 and the Historic Precinct, bounded by Little Bay Cove to the north, the golf course and Little Bay beach to the east, the Spinal Injuries / driving range land to the south and Anzac Parade to the west (D11 s 2.1). | not set by the DCP: ask the council | not set by the DCP: ask the council | not set by the DCP: ask the council | not set |
| Randwick DCP, Part D11 Prince Henry Site, Precinct P1 | Precinct P1 of the Prince Henry site: the north and west of the site around Oval Park, with detached dwelling lots 001 to 045 and apartment lots A, B, C1, E1 and 1 to 17 (D11 s 7.1, Figure 8). | 3m | not set by the DCP: ask the council | 3m | 3m |
What are the complying development setbacks for a granny flat?
If you build a granny flat with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 1.5m | 5m | 3m |
What if my block is on a corner?
Randwick DCP, Part C1 Low Density Residential (R2) sets a separate setback for a granny flat from the second street, the side street of a corner block: 0.9m on lots up to 6.99m wide, 1.5m on wider lots (Part C1, s 3.3.1 Front setbacks, control b)). The complying development figure for the second street is in the CDC table above.
Does a two storey granny flat need bigger setbacks?
No. Randwick DCP, Part C1 Low Density Residential (R2) sets the same figures for a one or two storey granny flat. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Randwick Council approve a granny flat closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Randwick?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Randwick Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.