Skip to main content

How close to the boundary can a house be in Randwick?

Randwick Council's main plan, Randwick DCP, Part C1 Low Density Residential (R2), asks a single storey house for these setbacks: front the average of the neighbouring homes (6m where there are none); side no figure on lots up to 5.99m wide, 0.9m on lots up to 8.99m wide, 0.9m on lots up to 11.99m wide, 1.2m on wider lots; and rear 25% of the lot depth on lots up to 32m deep, 8m on deeper lots.

In Randwick the setbacks for a house come from Randwick Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the house first.

Check your address

NSW addresses only. Free, and no sign up.

What setbacks does Randwick Council's main plan set for a house?

The table gives Randwick DCP, Part C1 Low Density Residential (R2)'s one and two storey figures and the clause each comes from. The plan covers this land: Zone R2 Low Density Residential land in Randwick.

Randwick DCP, Part C1 Low Density Residential (R2): setbacks for a house
SetbackOne storeyTwo storeysWhere in the plan
Frontthe average of the neighbouring homes (6m where there are none)the average of the neighbouring homes (6m where there are none)Part C1, s 3.3.1 Front setbacks, control a)
Sideno figure on lots up to 5.99m wide, 0.9m on lots up to 8.99m wide, 0.9m on lots up to 11.99m wide, 1.2m on wider lotsno figure on lots up to 5.99m wide; 0.9m on lots up to 8.99m wide; 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 11.99m wide; 1.2m, plus 0.25m for every metre of wall above 4.5m on wider lotsPart C1, s 3.3.2 Side setbacks, control a) and table "Minimum side setbacks" (read from the page image)
Rear25% of the lot depth on lots up to 32m deep, 8m on deeper lots25% of the lot depth on lots up to 32m deep, 8m on deeper lotsPart C1, s 3.3.3 Rear setbacks, control a)
Corner block, second street0.9m on lots up to 6.99m wide, 1.5m on wider lots0.9m on lots up to 6.99m wide, 1.5m on wider lotsPart C1, s 3.3.1 Front setbacks, control b)

Which DCP applies to my block in Randwick?

It depends on where the lot is. Randwick DCP, Part C1 Low Density Residential (R2) is Randwick Council's main plan, and 8 other plans cover a house on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.

Other plans in Randwick that cover a house
PlanWhere it appliesFrontSideRearSecond street
Randwick DCP, Part C1 Low Density Residential (R1, R3)Zone R1 General Residential and R3 Medium Density Residential land in Randwick outside the site specific parts traced below (Defence Site, Newmarket Green, Prince Henry, Little Bay Cove).the average of the neighbouring homes (6m where there are none)no figure on lots up to 5.99m wide, 0.9m on lots up to 8.99m wide, 0.9m on lots up to 11.99m wide, 1.2m on wider lots25% of the lot depth on lots up to 32m deep, 8m on deeper lots0.9m on lots up to 6.99m wide, 1.5m on wider lots
Randwick DCP, Part C1 Low Density Residential (RU4, Phillip Bay market gardens)Zone RU4 Primary Production Small Lots land (the Phillip Bay Chinese Market Garden, Randwick LEP 2012 RU4 objectives).the average of the neighbouring homes (6m where there are none)no figure on lots up to 5.99m wide, 0.9m on lots up to 8.99m wide, 0.9m on lots up to 11.99m wide, 1.2m on wider lots25% of the lot depth on lots up to 32m deep, 8m on deeper lots0.9m on lots up to 6.99m wide, 1.5m on wider lots
Randwick DCP, Part D8 Defence Site (Bundock and Avoca Streets, Kingsford)The Defence Site between Bundock Street, Avoca Street and Holmes Street, Kingsford (D8 Figure 1).3mno figure on lots up to 5.99m wide, 0.9m on lots up to 8.99m wide, 0.9m on lots up to 11.99m wide, 1.2m on wider lots6mnot set
Randwick DCP, Part D12 Newmarket GreenThe Newmarket Green key site, "generally bounded by Barker, Jane, Young, Middle and Botany Streets" (D12 s 1.2, Figure 1).3mno figure on lots up to 5.99m wide, 0.9m on lots up to 8.99m wide, 0.9m on lots up to 11.99m wide, 1.2m on wider lots25% of the lot depth on lots up to 32m deep, 8m on deeper lots3m
Randwick DCP, Part D13 Little Bay CoveThe Little Bay Cove site at 1406-1408 Anzac Parade, Little Bay, between Cawood Avenue, Anzac Parade, Gubbuteh Road and The Coast golf course (D13 Figure 1).3m1m to one side, 2m to the othernot set by the DCP: ask the councilnot set
Randwick DCP, Part D11 Prince Henry Site, Precinct P4Precinct P4 of the Prince Henry site: the detached dwelling lots D46 to D68 east of Ewing Avenue, between the Coast Hospital Memorial Park, Harvey Street and the golf course buffer (D11 s 7.4, Figure 14).3mno figure on lots up to 5.99m wide, 0.9m on lots up to 8.99m wide, 0.9m on lots up to 11.99m wide, 1.2m on wider lots8m4.5m
Randwick DCP, Part D11 Prince Henry Site, Little Bay (other precincts)The Prince Henry site at Little Bay outside Precinct P4: precincts P1, P2, P3, P5 and the Historic Precinct, bounded by Little Bay Cove to the north, the golf course and Little Bay beach to the east, the Spinal Injuries / driving range land to the south and Anzac Parade to the west (D11 s 2.1).not set by the DCP: ask the councilnot set by the DCP: ask the councilnot set by the DCP: ask the councilnot set
Randwick DCP, Part D11 Prince Henry Site, Precinct P1Precinct P1 of the Prince Henry site: the north and west of the site around Oval Park, with detached dwelling lots 001 to 045 and apartment lots A, B, C1, E1 and 1 to 17 (D11 s 7.1, Figure 8).3m1.5m25% of the lot depth on lots up to 32m deep, 8m on deeper lots3m

What are the complying development setbacks for a house?

If you build a house with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.

Complying development (CDC) setbacks for a house on three example lots
Example lotFrontSideRearCorner block, second street
450m² (15m wide, 30m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
600m² (15m wide, 40m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
1,000m² (20m wide, 50m deep)6.5m1.5m (2.1m at two storeys)5m (12m at two storeys)3m

What if my block is on a corner?

Randwick DCP, Part C1 Low Density Residential (R2) sets a separate setback for a house from the second street, the side street of a corner block: 0.9m on lots up to 6.99m wide, 1.5m on wider lots (Part C1, s 3.3.1 Front setbacks, control b)). On a corner block it also changes the other boundaries: rear no figure on lots up to 5.99m wide; 0.9m on lots up to 8.99m wide; 0.9m for one storey, 0.9m, plus 0.25m for every metre of wall above 4.5m for two storeys on lots up to 11.99m wide; 1.2m for one storey, 1.2m, plus 0.25m for every metre of wall above 4.5m for two storeys on wider lots. The complying development figure for the second street is in the CDC table above.

Does a two storey house need bigger setbacks?

Yes, under Randwick DCP, Part C1 Low Density Residential (R2): the side setback goes from no figure on lots up to 5.99m wide, 0.9m on lots up to 8.99m wide, 0.9m on lots up to 11.99m wide, 1.2m on wider lots to no figure on lots up to 5.99m wide; 0.9m on lots up to 8.99m wide; 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 11.99m wide; 1.2m, plus 0.25m for every metre of wall above 4.5m on wider lots. Under complying development, the two storey figures are in the CDC table above.

What else do people ask?

Can Randwick Council approve a house closer to the boundary?

It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.

Do these setbacks apply to a shed, pool or fence in Randwick?

No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.

When were the setbacks on this page checked?

We last read Randwick Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.

Where does this information come from?

These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.

What else can I check?

Check what applies to your block