How close to the boundary can a duplex be in Brewarrina?
Brewarrina Council's main plan, Brewarrina Shire DCP 2023, s 4.3 and 4.4 (RU5 Village), asks a single storey duplex for these setbacks: front 6m, side 1m and rear 1m.
In Brewarrina the setbacks for a duplex come from Brewarrina Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the duplex first.
NSW addresses only. Free, and no sign up.
What setbacks does Brewarrina Council's main plan set for a duplex?
The table gives Brewarrina Shire DCP 2023, s 4.3 and 4.4 (RU5 Village)'s one and two storey figures and the clause each comes from. The plan covers this land: Land zoned RU5 Village: Brewarrina town and the villages of Goodooga, Angledool, Weilmoringle and Gongolgon.
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | 6m | 6m | Brewarrina DCP 2023, s 4.4.1 Building Setbacks, table, row Village (RU5) |
| Side | 1m | 2m | Brewarrina DCP 2023, s 4.4.1 Building Setbacks, table, row Village (RU5) |
| Rear | 1m | 2m | Brewarrina DCP 2023, s 4.4.1 Building Setbacks, table, row Village (RU5) |
| Corner block, second street | 6m | 6m | Brewarrina DCP 2023, s 4.4.1 Building Setbacks, table, row Village (RU5), and the bullet under it |
Which DCP applies to my block in Brewarrina?
It depends on where the lot is. Brewarrina Shire DCP 2023, s 4.3 and 4.4 (RU5 Village) is Brewarrina Council's main plan, and 2 other plans cover a duplex on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Brewarrina Shire DCP 2023, s 4.3 and 4.4 (R5 Large Lot Residential) | All R5 Large Lot Residential land (285.0 ha around Brewarrina town), whatever its Lot Size Map minimum (2 ha or 4 ha). | 20m | 10m | 10m | 20m |
| Brewarrina Shire DCP 2023, s 4.3 and 4.4 (RU1 Primary Production) | Land zoned RU1 Primary Production (the rural shire outside the villages). | not set by the DCP: ask the council | not set by the DCP: ask the council | not set by the DCP: ask the council | not set |
What are the complying development setbacks for a duplex?
If you build a duplex with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 0.9m (1.5m at two storeys) | 5m (12m at two storeys) | 3m |
What if my block is on a corner?
Brewarrina Shire DCP 2023, s 4.3 and 4.4 (RU5 Village) sets a separate setback for a duplex from the second street, the side street of a corner block: 6m (Brewarrina DCP 2023, s 4.4.1 Building Setbacks, table, row Village (RU5), and the bullet under it). The complying development figure for the second street is in the CDC table above.
Does a two storey duplex need bigger setbacks?
Yes, under Brewarrina Shire DCP 2023, s 4.3 and 4.4 (RU5 Village): the side setback goes from 1m to 2m; the rear setback goes from 1m to 2m. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Brewarrina Council approve a duplex closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Brewarrina?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Brewarrina Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.