Skip to main content

How close to the boundary can a duplex be in Blayney?

Blayney Council's main plan, Blayney Shire DCP 2026, Part B (B2 Single Dwellings in Urban Areas, B5 Medium Density Housing): R1 and RU5, asks a single storey duplex for these setbacks: front at least 4.5m, or the street's established building line where that is further back; side 1.5m; and rear 1.5m.

In Blayney the setbacks for a duplex come from Blayney Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the duplex first.

Check your address

NSW addresses only. Free, and no sign up.

What setbacks does Blayney Council's main plan set for a duplex?

The table gives Blayney Shire DCP 2026, Part B (B2 Single Dwellings in Urban Areas, B5 Medium Density Housing): R1 and RU5's one and two storey figures and the clause each comes from. The plan covers this land: Land zoned R1 General Residential (Blayney and part of Millthorpe) and RU5 Village (Millthorpe and the other villages).

Blayney Shire DCP 2026, Part B (B2 Single Dwellings in Urban Areas, B5 Medium Density Housing): R1 and RU5: setbacks for a duplex
SetbackOne storeyTwo storeysWhere in the plan
Frontat least 4.5m, or the street's established building line where that is further backat least 6m, or the street's established building line where that is further backPart B, B5.5 2) table, Primary St (street with driveway) FRONT SETBACK
Side1.5m3mPart B, B5.5 2) table, Side & Rear Boundary (no road frontage)
Rear1.5m3mPart B, B5.5 2) table, Side & Rear Boundary (no road frontage)
Corner block, second street3m4.5mPart B, B5.5 2) table, Secondary St (corner lots)

Which DCP applies to my block in Blayney?

It depends on where the lot is. Blayney Shire DCP 2026, Part B (B2 Single Dwellings in Urban Areas, B5 Medium Density Housing): R1 and RU5 is Blayney Council's main plan, and 3 other plans cover a duplex on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.

Other plans in Blayney that cover a duplex
PlanWhere it appliesFrontSideRearSecond street
Blayney Shire DCP 2026, Part B (B2 Single Dwellings in Urban Areas, B5 Medium Density Housing): E1 Local CentreLand zoned E1 Local Centre (the Town of Blayney).at least 4.5m, or the street's established building line where that is further back1.5m1.5m3m
Blayney Shire DCP 2026, Part B (B2, B4 Large Lot & Rural Dwellings, B5): R5 Large Lot ResidentialLand zoned R5 Large Lot Residential.at least 4.5m, or the street's established building line where that is further back on lots up to 9,999.99m²; 20m on larger lots1.5m on lots up to 9,999.99m²; 10m on larger lots1.5m on lots up to 9,999.99m²; 10m on larger lots3m on lots up to 9,999.99m²; 20m on larger lots
Blayney Shire DCP 2026, Part B4 Large Lot & Rural Dwellings (including Rural Dual Occupancies): RU1 and RU2Land zoned RU1 Primary Production and RU2 Rural Landscape.20m10m10m20m

What are the complying development setbacks for a duplex?

If you build a duplex with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.

Complying development (CDC) setbacks for a duplex on three example lots
Example lotFrontSideRearCorner block, second street
450m² (15m wide, 30m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
600m² (15m wide, 40m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
1,000m² (20m wide, 50m deep)6.5m0.9m (1.5m at two storeys)5m (12m at two storeys)3m

What if my block is on a corner?

Blayney Shire DCP 2026, Part B (B2 Single Dwellings in Urban Areas, B5 Medium Density Housing): R1 and RU5 sets a separate setback for a duplex from the second street, the side street of a corner block: 3m for one storey, 4.5m for two storeys (Part B, B5.5 2) table, Secondary St (corner lots)). The complying development figure for the second street is in the CDC table above.

Does a two storey duplex need bigger setbacks?

Yes, under Blayney Shire DCP 2026, Part B (B2 Single Dwellings in Urban Areas, B5 Medium Density Housing): R1 and RU5: the front setback goes from at least 4.5m, or the street's established building line where that is further back to at least 6m, or the street's established building line where that is further back; the side setback goes from 1.5m to 3m; the rear setback goes from 1.5m to 3m; the corner block, second street setback goes from 3m to 4.5m. Under complying development, the two storey figures are in the CDC table above.

What else do people ask?

Can Blayney Council approve a duplex closer to the boundary?

It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.

Do these setbacks apply to a shed, pool or fence in Blayney?

No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.

When were the setbacks on this page checked?

We last read Blayney Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.

Where does this information come from?

These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.

What else can I check?

Check what applies to your block