How close to the boundary can a duplex be in Bellingen?

Bellingen Council's main plan, Bellingen Shire DCP 2017, Chapters 1 and 2 (R1 General Residential), asks a single storey duplex for these setbacks: front at least 4.5m, or the street's established building line where that is further back; side inside a plane rising at 35° from 3m above the boundary, and at least 0.9m; and rear inside a plane rising at 35° from 3m above the boundary.

In Bellingen the setbacks for a duplex come from Bellingen Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the duplex first.

Check your address

NSW addresses only. Free, and no sign up.

What setbacks does Bellingen Council's main plan set for a duplex?

The table gives Bellingen Shire DCP 2017, Chapters 1 and 2 (R1 General Residential)'s one and two storey figures and the clause each comes from. The plan covers this land: R1 General Residential land in Bellingen Shire (the towns and villages, including Bellingen, North Bellingen and its Chapter 17 urban release area, Urunga, Dorrigo and Mylestom).

Bellingen Shire DCP 2017, Chapters 1 and 2 (R1 General Residential): setbacks for a duplex
SetbackOne storeyTwo storeysWhere in the plan
Frontat least 4.5m, or the street's established building line where that is further backat least 4.5m, or the street's established building line where that is further backBellingen Shire DCP 2017, Chapter 2 Multiple Dwelling Construction, 2.6.5 Setbacks from boundaries and 2.6.6 The Building Height Plane Envelope; Bellingen Shire DCP 2017, Chapter 1 Single Dwellings, 1.6.1 Setbacks from boundaries, criterion 1, Table 1.1
Sideinside a plane rising at 35° from 3m above the boundary, and at least 0.9minside a plane rising at 35° from 3m above the boundary, and at least 0.9mBellingen Shire DCP 2017, Chapter 2 Multiple Dwelling Construction, 2.6.5 Setbacks from boundaries and 2.6.6 The Building Height Plane Envelope; Bellingen Shire DCP 2017, Chapter 1 Single Dwellings, 1.6.1 Setbacks from boundaries, criterion 1, Table 1.1; Bellingen Shire DCP 2017, Chapter 1 Single Dwellings, 1.6.3 The Building Height Plane Envelope, criterion 1 and Figure 1.1
Rearinside a plane rising at 35° from 3m above the boundaryinside a plane rising at 35° from 3m above the boundaryBellingen Shire DCP 2017, Chapter 2 Multiple Dwelling Construction, 2.6.5 Setbacks from boundaries and 2.6.6 The Building Height Plane Envelope; Bellingen Shire DCP 2017, Chapter 1 Single Dwellings, 1.6.1 Setbacks from boundaries, criterion 1, Table 1.1; Bellingen Shire DCP 2017, Chapter 1 Single Dwellings, 1.6.3 The Building Height Plane Envelope, criterion 1 and Figure 1.1
Corner block, second streetinside a plane rising at 35° from 3m above the boundary, and at least 3minside a plane rising at 35° from 3m above the boundary, and at least 3mBellingen Shire DCP 2017, Chapter 2 Multiple Dwelling Construction, 2.6.5 Setbacks from boundaries and 2.6.6 The Building Height Plane Envelope; Bellingen Shire DCP 2017, Chapter 1 Single Dwellings, 1.6.1 Setbacks from boundaries, criterion 1, Table 1.1; Bellingen Shire DCP 2017, Chapter 1 Single Dwellings, 1.6.3 The Building Height Plane Envelope, criterion 1 and Figure 1.1

Which DCP applies to my block in Bellingen?

It depends on where the lot is. Bellingen Shire DCP 2017, Chapters 1 and 2 (R1 General Residential) is Bellingen Council's main plan, and 2 other plans cover a duplex on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.

Other plans in Bellingen that cover a duplex
PlanWhere it appliesFrontSideRearSecond street
Bellingen Shire DCP 2017, Chapters 1 and 2 (R5 Large Lot Residential)R5 Large Lot Residential land in Bellingen Shire.10m5m5m10m
Bellingen Shire DCP 2017, Chapters 1 and 2 (RU1, RU2 and RU4 rural zones)RU1 Primary Production, RU2 Rural Landscape and RU4 Primary Production Small Lots land in Bellingen Shire.20m10m10m20m

What are the complying development setbacks for a duplex?

If you build a duplex with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.

Complying development (CDC) setbacks for a duplex on three example lots
Example lotFrontSideRearCorner block, second street
450m² (15m wide, 30m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
600m² (15m wide, 40m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
1,000m² (20m wide, 50m deep)6.5m0.9m (1.5m at two storeys)5m (12m at two storeys)3m

What if my block is on a corner?

Bellingen Shire DCP 2017, Chapters 1 and 2 (R1 General Residential) sets a separate setback for a duplex from the second street, the side street of a corner block: inside a plane rising at 35° from 3m above the boundary, and at least 3m (Bellingen Shire DCP 2017, Chapter 2 Multiple Dwelling Construction, 2.6.5 Setbacks from boundaries and 2.6.6 The Building Height Plane Envelope; Bellingen Shire DCP 2017, Chapter 1 Single Dwellings, 1.6.1 Setbacks from boundaries, criterion 1, Table 1.1; Bellingen Shire DCP 2017, Chapter 1 Single Dwellings, 1.6.3 The Building Height Plane Envelope, criterion 1 and Figure 1.1). The complying development figure for the second street is in the CDC table above.

Does a two storey duplex need bigger setbacks?

Yes, through the wall height: under Bellingen Shire DCP 2017, Chapters 1 and 2 (R1 General Residential) the side, rear and corner block, second street setback grows as the wall gets taller. Under complying development, the two storey figures are in the CDC table above.

What else do people ask?

Can Bellingen Council approve a duplex closer to the boundary?

It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.

Do these setbacks apply to a shed, pool or fence in Bellingen?

No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.

When were the setbacks on this page checked?

We last read Bellingen Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.

Where does this information come from?

These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.

What else can I check?

Check what applies to your block