Skip to main content

How close to the boundary can a house be in Glen Innes Severn?

Glen Innes Severn Council's main plan, Glen Innes Severn DCP 2014, Chapter 3 Residential Development: R1 and RU5, asks a single storey house for these setbacks: front the average of the neighbouring homes (6m where there are none), side 0.9m and rear 0.9m.

In Glen Innes Severn the setbacks for a house come from Glen Innes Severn Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the house first.

Check your address

NSW addresses only. Free, and no sign up.

What setbacks does Glen Innes Severn Council's main plan set for a house?

The table gives Glen Innes Severn DCP 2014, Chapter 3 Residential Development: R1 and RU5's one and two storey figures and the clause each comes from. The plan covers this land: Land zoned R1 General Residential (Glen Innes) and RU5 Village (Deepwater, Emmaville, Glencoe and the other villages), outside the R2 Hunter Street release area.

Glen Innes Severn DCP 2014, Chapter 3 Residential Development: R1 and RU5: setbacks for a house
SetbackOne storeyTwo storeysWhere in the plan
Frontthe average of the neighbouring homes (6m where there are none)the average of the neighbouring homes (6m where there are none)Chapter 3, s 3.5 Setbacks (Controls, second bullet) and Chapter 3, s 3.5 Setbacks, Table 3.2 Minimum Setbacks, R1/RU5 Dwelling / Dual Occupancy row, Street
Side0.9m2m for walls greater than 3 m in heightChapter 3, s 3.5 Setbacks, Table 3.2 Minimum Setbacks, R1/RU5 Dwelling / Dual Occupancy row, Side/Rear; and the paragraph below the table
Rear0.9m2m for walls greater than 3 m in heightChapter 3, s 3.5 Setbacks, Table 3.2 Minimum Setbacks, R1/RU5 Dwelling / Dual Occupancy row, Side/Rear; and the paragraph below the table
Corner block, second street3m3mChapter 3, s 3.5 Setbacks, Table 3.2 Minimum Setbacks, R1/RU5 Dwelling / Dual Occupancy row, Street

Which DCP applies to my block in Glen Innes Severn?

It depends on where the lot is. Glen Innes Severn DCP 2014, Chapter 3 Residential Development: R1 and RU5 is Glen Innes Severn Council's main plan, and 5 other plans cover a house on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.

Other plans in Glen Innes Severn that cover a house
PlanWhere it appliesFrontSideRearSecond street
Glen Innes Severn DCP 2014, Chapter 3 Residential Development and Chapter 4 Rural Development: R5 Large Lot ResidentialLand zoned R5 Large Lot Residential (the rural residential land north and south of Glen Innes).15m3m3mnot set
Glen Innes Severn DCP 2014, Chapter 10 Hunter Street Urban Release Area (R2)The Hunter Street Urban Land Release Area on the east edge of Glen Innes (MAP 1, "heavy black edging"), which s 10.2 says "is zoned R2 Low Density Residential".6m0.9m0.9m3m
Glen Innes Severn DCP 2014, Chapter 4 Rural Development: RU1 Primary ProductionLand zoned RU1 Primary Production.15mnot set by the DCP: ask the councilnot set by the DCP: ask the councilnot set
Glen Innes Severn DCP 2014, Chapter 4 Rural Development: C3 Environmental ManagementLand zoned C3 Environmental Management (named "E3" in the 2014 chapter).15mnot set by the DCP: ask the councilnot set by the DCP: ask the councilnot set
Glen Innes Severn DCP 2014, Chapter 6 Development in Commercial and Industrial Areas: MU1 Mixed UseLand zoned MU1 Mixed Use (three small areas: south of Lang Street and west of the Glen Innes CBD).not set by the DCP: ask the councilnot set by the DCP: ask the councilnot set by the DCP: ask the councilnot set

What are the complying development setbacks for a house?

If you build a house with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.

Complying development (CDC) setbacks for a house on three example lots
Example lotFrontSideRearCorner block, second street
450m² (15m wide, 30m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
600m² (15m wide, 40m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
1,000m² (20m wide, 50m deep)6.5m1.5m (2.1m at two storeys)5m (12m at two storeys)3m

What if my block is on a corner?

Glen Innes Severn DCP 2014, Chapter 3 Residential Development: R1 and RU5 sets a separate setback for a house from the second street, the side street of a corner block: 3m (Chapter 3, s 3.5 Setbacks, Table 3.2 Minimum Setbacks, R1/RU5 Dwelling / Dual Occupancy row, Street). The complying development figure for the second street is in the CDC table above.

Does a two storey house need bigger setbacks?

Yes, under Glen Innes Severn DCP 2014, Chapter 3 Residential Development: R1 and RU5: the side setback goes from 0.9m to 2m for walls greater than 3 m in height; the rear setback goes from 0.9m to 2m for walls greater than 3 m in height. Under complying development, the two storey figures are in the CDC table above.

What else do people ask?

Can Glen Innes Severn Council approve a house closer to the boundary?

It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.

Do these setbacks apply to a shed, pool or fence in Glen Innes Severn?

No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.

When were the setbacks on this page checked?

We last read Glen Innes Severn Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.

Where does this information come from?

These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.

What else can I check?

Check what applies to your block