How close to the boundary can a house be in Bayside?
Bayside Council's main plan, Bayside DCP 2022, s 5.1.2 and s 5.2.1 (low density residential), asks a single storey house for these setbacks: front the average of the neighbouring homes (6m where there are none), side 0.9m and rear 5m.
In Bayside the setbacks for a house come from Bayside Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the house first.
NSW addresses only. Free, and no sign up.
What setbacks does Bayside Council's main plan set for a house?
The table gives Bayside DCP 2022, s 5.1.2 and s 5.2.1 (low density residential)'s one and two storey figures and the clause each comes from. The plan covers this land: Land zoned R2, R3 or R4 in the Bayside LGA outside the Arncliffe sub-precincts of s 7.4 and the Bonar Street Precinct of s 7.5.
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | the average of the neighbouring homes (6m where there are none) | the average of the neighbouring homes (6m where there are none) | Bayside DCP 2022, s 5.2.1.3 Setbacks, C1 |
| Side | 0.9m | 1.5m for first storey and above | Bayside DCP 2022, s 5.2.1.3 Setbacks, C6 |
| Rear | 5m | 30% of the lot depth, and at least 5m for the two or three storey part of the development only; a single storey part may extend to the rear setback | Bayside DCP 2022, s 5.2.1.3 Setbacks, C5; s 5.2.1.2 Built Form Controls, C4 |
| Corner block, second street | 1.5m | 1.5m | Bayside DCP 2022, s 5.2.1.3 Setbacks, C2 |
Which DCP applies to my block in Bayside?
It depends on where the lot is. Bayside DCP 2022, s 5.1.2 and s 5.2.1 (low density residential) is Bayside Council's main plan, and 3 other plans cover a house on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Bayside DCP 2022, s 5.2.1 (dwelling houses in Zone RU4) | Land zoned RU4 Primary Production Small Lots (the heritage listed market gardens). | the average of the neighbouring homes (6m where there are none) | 0.9m | 5m | 1.5m |
| Bayside DCP 2022, s 7.4 Arncliffe and Banksia (Arncliffe sub-precincts east of the railway) | R2, R3 and R4 land in the Arncliffe part of the s 7.4 Arncliffe and Banksia precinct (Figure 56: sub-precincts 1 Arncliffe Town Centre, 3 Allen Street Neighbourhood, 4 Cahill Park Neighbourhood and 5 Arncliffe School Neighbourhood, and the Princes Highway Arncliffe special character area), east of the Illawarra railway. | 3m | 0.9m | 5m | 1.5m |
| Bayside DCP 2022, s 7.5 Bonar Street Precinct | R2, R3 and R4 land in the Bonar Street Precinct, Arncliffe (s 7.5, Figure 75: Bonar Street Precinct Land Application Map): the R4 block between Edward Street, Loftus Street, Bonar Street, Martin Avenue and Wollongong Road. | 5m | 0.9m | 5m | 1.5m |
What are the complying development setbacks for a house?
If you build a house with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 1.5m (2.1m at two storeys) | 5m (12m at two storeys) | 3m |
What if my block is on a corner?
Bayside DCP 2022, s 5.1.2 and s 5.2.1 (low density residential) sets a separate setback for a house from the second street, the side street of a corner block: 1.5m (Bayside DCP 2022, s 5.2.1.3 Setbacks, C2). The complying development figure for the second street is in the CDC table above.
Does a two storey house need bigger setbacks?
Yes, under Bayside DCP 2022, s 5.1.2 and s 5.2.1 (low density residential): the side setback goes from 0.9m to 1.5m for first storey and above; the rear setback goes from 5m to 30% of the lot depth, and at least 5m for the two or three storey part of the development only; a single storey part may extend to the rear setback. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Bayside Council approve a house closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Bayside?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Bayside Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.