Skip to main content

How close to the boundary can a house be in Balranald?

Balranald Council's main plan, Balranald Building Setback Policy (a council policy, not a DCP), RU5 Village, asks a single storey house for these setbacks: front 6m. It does not set a side or rear setback: ask the council.

In Balranald the setbacks for a house come from Balranald Council's setback policy, which stands in for a development control plan (DCP), unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the house first.

Check your address

NSW addresses only. Free, and no sign up.

What setbacks does Balranald Council's main plan set for a house?

The table gives Balranald Building Setback Policy (a council policy, not a DCP), RU5 Village's one and two storey figures and the clause each comes from. The plan covers this land: Land zoned RU5 Village: the towns of Balranald and Euston and the village of Kyalite (LEP RU5 objective: "To define the town boundaries of Balranald, Euston and Kyalite").

Balranald Building Setback Policy (a council policy, not a DCP), RU5 Village: setbacks for a house
SetbackOne storeyTwo storeysWhere in the plan
Front6m6mBuilding Setback Policy, Policy Statement 1
Sidenot set by the council's policy: ask the councilnot set by the council's policy: ask the councilNone
Rearnot set by the council's policy: ask the councilnot set by the council's policy: ask the councilNone
Corner block, second streetno figure on lots up to 199.99m²; 2m on lots up to 600m²; 3m on lots up to 1,500m²; 5m on larger lotsno figure on lots up to 199.99m²; 2m on lots up to 600m²; 3m on lots up to 1,500m²; 5m on larger lotsBuilding Setback Policy, Policy Statement 2 and Table 1

Which DCP applies to my block in Balranald?

It depends on where the lot is. Balranald Building Setback Policy (a council policy, not a DCP), RU5 Village is Balranald Council's main plan, and one other plan covers a house on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.

Other plans in Balranald that cover a house
PlanWhere it appliesFrontSideRearSecond street
Balranald Shire: no DCP (RU1 Primary Production and RU4 Primary Production Small Lots)Land zoned RU1 Primary Production or RU4 Primary Production Small Lots (the farming land of the shire).not set (the council has no DCP): ask the councilnot set (the council has no DCP): ask the councilnot set (the council has no DCP): ask the councilnot set

What are the complying development setbacks for a house?

If you build a house with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.

Complying development (CDC) setbacks for a house on three example lots
Example lotFrontSideRearCorner block, second street
450m² (15m wide, 30m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
600m² (15m wide, 40m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
1,000m² (20m wide, 50m deep)6.5m1.5m (2.1m at two storeys)5m (12m at two storeys)3m

What if my block is on a corner?

Balranald Building Setback Policy (a council policy, not a DCP), RU5 Village sets a separate setback for a house from the second street, the side street of a corner block: no figure on lots up to 199.99m²; 2m on lots up to 600m²; 3m on lots up to 1,500m²; 5m on larger lots (Building Setback Policy, Policy Statement 2 and Table 1). The complying development figure for the second street is in the CDC table above.

Does a two storey house need bigger setbacks?

No. Balranald Building Setback Policy (a council policy, not a DCP), RU5 Village sets the same figures for a one or two storey house. Under complying development, the two storey figures are in the CDC table above.

What else do people ask?

Can Balranald Council approve a house closer to the boundary?

It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.

Do these setbacks apply to a shed, pool or fence in Balranald?

No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.

When were the setbacks on this page checked?

We last read Balranald Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.

Where does this information come from?

These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.

What else can I check?

Check what applies to your block