How close to the boundary can a granny flat be in Weddin?
Weddin Council's main plan, Weddin DCP 2014, Chapters 5 and 6 (urban and village housing), asks a single storey granny flat for these setbacks: front 6m, side 0.9m and rear 0.9m.
In Weddin the setbacks for a granny flat come from Weddin Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the granny flat first.
NSW addresses only. Free, and no sign up.
What setbacks does Weddin Council's main plan set for a granny flat?
The table gives Weddin DCP 2014, Chapters 5 and 6 (urban and village housing)'s one and two storey figures and the clause each comes from. The plan covers this land: Land zoned R1 General Residential (Grenfell) and RU5 Village (Caragabal, Quandialla, Greenethorpe, Bimbi and a small RU5 parcel in Grenfell) under Weddin LEP 2011.
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | 6m | 6m | Weddin DCP 2014, Chapter 6, s 6.9 Setback to the Street, Standard 1 |
| Side | 0.9m | 1.5m for second storey | Weddin DCP 2014, Chapter 6, s 6.10 Side Setback, Standards 1 and 2 |
| Rear | 0.9m | 1.5m for second storey | Weddin DCP 2014, Chapter 6, s 6.10 Side Setback, Standards 1 and 2 |
| Corner block, second street | 3m | 3m | Weddin DCP 2014, Chapter 6, s 6.9 Setback to the Street, Standard 2 |
Which DCP applies to my block in Weddin?
It depends on where the lot is. Weddin DCP 2014, Chapters 5 and 6 (urban and village housing) is Weddin Council's main plan, and 2 other plans cover a granny flat on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Weddin DCP 2014, Chapter 7 (Large Lot Residential) with Chapter 6 for granny flats | Land zoned R5 Large Lot Residential under Weddin LEP 2011 (about 1,420 ha around Grenfell; Lot Size Map 4,000 m2, 1 ha, 2 ha and 10 ha). | 6m | 0.9m | 0.9m | 3m |
| Weddin DCP 2014, Chapter 9 (Rural Development) with Chapter 6 for granny flats | Land zoned RU1 Primary Production under Weddin LEP 2011. | 30m | 0.9m | 0.9m | 30m |
What are the complying development setbacks for a granny flat?
If you build a granny flat with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 1.5m | 5m | 3m |
What if my block is on a corner?
Weddin DCP 2014, Chapters 5 and 6 (urban and village housing) sets a separate setback for a granny flat from the second street, the side street of a corner block: 3m (Weddin DCP 2014, Chapter 6, s 6.9 Setback to the Street, Standard 2). The complying development figure for the second street is in the CDC table above.
Does a two storey granny flat need bigger setbacks?
Yes, under Weddin DCP 2014, Chapters 5 and 6 (urban and village housing): the side setback goes from 0.9m to 1.5m for second storey; the rear setback goes from 0.9m to 1.5m for second storey. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Weddin Council approve a granny flat closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Weddin?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Weddin Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.