How close to the boundary can a granny flat be in MidCoast?
MidCoast Council's main plan, Greater Taree DCP 2010, Part H Residential Requirements, names a granny flat but sets no front, side or rear setback for one, so a development application is assessed on its merits. Ask the council what it expects.
In MidCoast the setbacks for a granny flat come from MidCoast Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the granny flat first.
NSW addresses only. Free, and no sign up.
What setbacks does MidCoast Council's main plan set for a granny flat?
MidCoast Council's main plan, Greater Taree DCP 2010, Part H Residential Requirements, names a granny flat but sets no front, side or rear setback for one, so a development application is assessed on its merits. Ask the council what it expects.
Which DCP applies to my block in MidCoast?
It depends on where the lot is. Greater Taree DCP 2010, Part H Residential Requirements is MidCoast Council's main plan, and 14 other plans cover a granny flat on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Great Lakes DCP, Chapter 16, s 16.14 Macwood Road, Smiths Lake: Future Development (Precinct 7) | Future Development (Precinct 7) of the Macwood Road estate, around the existing dwellings. | the average of the neighbouring homes (4.5m on lots up to 899.99m², 6m on larger lots where there are none) | 0.9m | 3m | the average of the neighbouring homes (3m where there are none) |
| Greater Taree DCP 2010, Part L, L5 Precinct 2B, Old Bar | "All land within the site known as Precinct 2B, Old Bar and shown in Figure 3": the land west of Old Bar Road's town centre, between Red Gum Road and the southern rural lots, either side of Old Bar Road. | 4.5m | not set by the DCP: ask the council | not set by the DCP: ask the council | not set |
| Great Lakes DCP, Chapter 16, s 16.17 Memorial Avenue, Stroud | "This Part applies to Lot 61 DP 95868 Memorial Avenue Stroud", since subdivided into Lots 1 to 6 DP 1316734. | 4.5m | 3.5m to one side, 2.5m to the other | 4.5m | the average of the neighbouring homes (3m where there are none) |
| Great Lakes DCP, Chapter 16, s 16.18 Minimbah Road and Hillcrest Road, Nabiac | The "Acacia" rural residential subdivision of Lots 4 and 6 DP 261078 and Lot 31 DP 819686, Minimbah and Hillcrest Roads, Nabiac (now Lot 104 DP 1116095, Lots 50 to 52 DP 1105611 and Lots 1 to 4 DP 1050029). | 20m | 20m | 20m | 20m |
| Great Lakes DCP, Chapter 16, s 16.25 Stroud, Residential Development | Residential and village land in Stroud. | the average of the neighbouring homes | 3.5m to one side, 2.5m to the other | 4.5m | the average of the neighbouring homes |
| Great Lakes DCP, Chapter 5, Seal Rocks site specific setbacks | Residential and village land in Seal Rocks: "In Seal Rocks, a front building line setback of 6m applies to all sites". | 6m | 0.9m | 3m | the average of the neighbouring homes (3m where there are none) |
| Greater Taree DCP 2010, Part H, s H3.6 Dwellings in R5 zones | R5 Large Lot Residential land in the former Greater Taree council area. | 10m | 5m | 5m | not set |
| Great Lakes DCP, Chapter 5 Single Dwellings, Dual Occupancies, Villas and Townhouses (Residential and Village Zones) | Residential and village land (R1, R2, R3, RU5) in the former Great Lakes council area (Forster, Tuncurry, Tea Gardens, Hawks Nest, Nabiac, Bulahdelah, Pacific Palms, Smiths Lake and the villages), outside Seal Rocks and the Chapter 16 sites below. | the average of the neighbouring homes (4.5m on lots up to 899.99m², 6m on larger lots where there are none) | 0.9m | 3m | the average of the neighbouring homes (3m where there are none) |
Show 6 more plans
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Great Lakes DCP, Chapter 5 Single Dwellings, Dual Occupancies, Villas and Townhouses (R4 High Density Residential) | R4 High Density Residential land in the former Great Lakes council area, under the same s 5.5.2 "Residential and Village Zones" controls. | the average of the neighbouring homes (4.5m on lots up to 899.99m², 6m on larger lots where there are none) | 0.9m | 3m | the average of the neighbouring homes (3m where there are none) |
| Great Lakes DCP, Chapter 5, s 5.5.3 Large Lot Residential Zone | R5 Large Lot Residential land in the former Great Lakes council area. | 18m | 5m | 5m | not set |
| Great Lakes DCP, Chapter 5, s 5.5.4 Rural and Environmental Zones (RU2) | RU2 Rural Landscape land in the former Great Lakes council area (s 5.5.4 Rural and Environmental Zones). | 18m | 10m | 10m | not set |
| Gloucester DCP 2010, s 4.6 Building Line Setback Guidelines (R1, R2, RU5) | R1 General Residential, R2 Low Density Residential and RU5 Village land in the former Gloucester council area (Gloucester, Barrington, Stratford, Craven). | 6m | 1m | 1m | 3m |
| Gloucester DCP 2010, s 4.6 Building Line Setback Guidelines (R3) | R3 Medium Density Residential land in the former Gloucester council area. | 6m | 3m | 3m | 3m |
| Gloucester DCP 2010, s 4.6 Building Line Setback Guidelines (R5) | R5 Large Lot Residential land in the former Gloucester council area. | 15m on lots up to 7,999.99m²; 30m on larger lots | 7.5m on lots up to 7,999.99m²; 15m on larger lots | 7.5m on lots up to 7,999.99m²; 15m on larger lots | 7.5m on lots up to 7,999.99m²; 15m on larger lots |
What are the complying development setbacks for a granny flat?
If you build a granny flat with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 1.5m | 5m | 3m |
What if my block is on a corner?
Greater Taree DCP 2010, Part H Residential Requirements sets no separate setback for the second street of a corner block for a granny flat, so ask the council how it treats one. The complying development figure for the second street is in the CDC table above.
Does a two storey granny flat need bigger setbacks?
Greater Taree DCP 2010, Part H Residential Requirements sets no setbacks for a granny flat of any height, so ask the council. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can MidCoast Council approve a granny flat closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in MidCoast?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read MidCoast Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.