How close to the boundary can a granny flat be in Bogan?
Bogan Council's main plan, Bogan DCP 2012, Step 2 (R1 General Residential), asks a single storey granny flat for these setbacks: front 6m, side left to the Building Code (0.9m) and rear left to the Building Code (0.9m).
In Bogan the setbacks for a granny flat come from Bogan Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the granny flat first.
NSW addresses only. Free, and no sign up.
What setbacks does Bogan Council's main plan set for a granny flat?
The table gives Bogan DCP 2012, Step 2 (R1 General Residential)'s one and two storey figures and the clause each comes from. The plan covers this land: Land zoned R1 General Residential (Nyngan; 2 polygons, about 275 ha).
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | 6m | 6m | Bogan DCP 2012, Step 2, General Housing & Ancillary Structures Development Controls, Dwelling Setbacks table, row R1 (p 11) |
| Side | left to the Building Code (0.9m) | left to the Building Code (0.9m) | Bogan DCP 2012, Step 2, General Housing & Ancillary Structures Development Controls, Dwelling Setbacks table, row R1 (p 11) |
| Rear | left to the Building Code (0.9m) | left to the Building Code (0.9m) | Bogan DCP 2012, Step 2, General Housing & Ancillary Structures Development Controls, Dwelling Setbacks table, row R1 (p 11) |
| Corner block, second street | 6m | 6m | Bogan DCP 2012, Step 2, General Housing & Ancillary Structures Development Controls, Dwelling Setbacks table, row R1 (p 11); Subdivision Development Controls, Lot size (p 19) |
Which DCP applies to my block in Bogan?
It depends on where the lot is. Bogan DCP 2012, Step 2 (R1 General Residential) is Bogan Council's main plan, and 3 other plans cover a granny flat on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Bogan DCP 2012, Step 2 (RU5 Village) | Land zoned RU5 Village: Hermidale, Coolabah and Girilambone (5 polygons, about 76 ha). | 6m | left to the Building Code (0.9m) | left to the Building Code (0.9m) | 6m |
| Bogan DCP 2012, Step 2 (R5 Large Lot Residential) | Land zoned R5 Large Lot Residential, around Nyngan (7 polygons, about 296 ha). | 10m | 1.5m | 1.5m | 10m |
| Bogan DCP 2012, Step 2 (E1 Local Centre, the DCP's B2) | Land zoned E1 Local Centre, the Nyngan town centre (1 polygon, about 17 ha). | not set by the DCP: ask the council | not set by the DCP: ask the council | not set by the DCP: ask the council | not set |
What are the complying development setbacks for a granny flat?
If you build a granny flat with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 1.5m | 5m | 3m |
What if my block is on a corner?
Bogan DCP 2012, Step 2 (R1 General Residential) sets a separate setback for a granny flat from the second street, the side street of a corner block: 6m (Bogan DCP 2012, Step 2, General Housing & Ancillary Structures Development Controls, Dwelling Setbacks table, row R1 (p 11); Subdivision Development Controls, Lot size (p 19)). The complying development figure for the second street is in the CDC table above.
Does a two storey granny flat need bigger setbacks?
No. Bogan DCP 2012, Step 2 (R1 General Residential) sets the same figures for a one or two storey granny flat. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Bogan Council approve a granny flat closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Bogan?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Bogan Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.