Skip to main content

How close to the boundary can a duplex be in Wollondilly?

Wollondilly Council's main plan, Wollondilly DCP 2016, Volume 4 Residential Development, asks a single storey duplex for these setbacks: front the average of the neighbouring homes (4.5m where there are none), side 0.9m and rear 3m.

In Wollondilly the setbacks for a duplex come from Wollondilly Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the duplex first.

Check your address

NSW addresses only. Free, and no sign up.

What setbacks does Wollondilly Council's main plan set for a duplex?

The table gives Wollondilly DCP 2016, Volume 4 Residential Development's one and two storey figures and the clause each comes from. The plan covers this land: All land to which Wollondilly LEP 2011 applies (Vol 1 s 1.1), less the Wilton Growth Area and Greater Macarthur Growth Area precincts, where the growth area DCPs replace it, and less the zones and areas given their own plans below.

Wollondilly DCP 2016, Volume 4 Residential Development: setbacks for a duplex
SetbackOne storeyTwo storeysWhere in the plan
Frontthe average of the neighbouring homes (4.5m where there are none)the average of the neighbouring homes (4.5m where there are none)Wollondilly DCP 2016, Vol 4, s 3.16 controls 21 to 23
Side0.9m0.9mWollondilly DCP 2016, Vol 4, s 3.16 control 25
Rear3m8m for the two storey part of the house; a single storey part may sit 3m from the rearWollondilly DCP 2016, Vol 4, s 3.16 control 26
Corner block, second street2.5m on lots up to 899.99m², 3m on larger lots2.5m on lots up to 899.99m², 3m on larger lotsWollondilly DCP 2016, Vol 4, s 3.16 control 24

Which DCP applies to my block in Wollondilly?

It depends on where the lot is. Wollondilly DCP 2016, Volume 4 Residential Development is Wollondilly Council's main plan, and 12 other plans cover a duplex on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.

Other plans in Wollondilly that cover a duplex
PlanWhere it appliesFrontSideRearSecond street
Wollondilly DCP 2016, Volume 4 (rural and environmental zones)Land in rural and environmental zones under Wollondilly LEP 2011.18m5m10m10m
Wollondilly DCP 2016, Volume 4 (Zone R5 Large Lot Residential)Land in Zone R5 Large Lot Residential under Wollondilly LEP 2011.not set by the DCP: ask the councilnot set by the DCP: ask the councilnot set by the DCP: ask the councilnot set
Wollondilly DCP 2016, Volume 4, s 4.2 Bingara Gorge EstateSection 4.2: "This section applies to the Wilton Park Urban Release Area under Wollondilly Local Environmental Plan, 2011." (the Bingara Gorge estate).the average of the neighbouring homes (4.5m where there are none)0.9m3m2.5m on lots up to 899.99m², 3m on larger lots
Wollondilly DCP 2016, Volume 1, s 6.3 Menangle Heritage Conservation AreaR2 and R3 land in the Menangle Conservation Area (Wollondilly LEP 2011 Schedule 5, C1; about 56% of the area is R2).6m0.9m3m2.5m on lots up to 899.99m², 3m on larger lots
Wollondilly DCP 2016, Volume 1, s 6.3 Menangle Heritage Conservation Area (rural zones)Rural and environmental zoned land in the Menangle Conservation Area (Wollondilly LEP 2011 Schedule 5, C1; mostly RU1, with some RU5).18m5m10m10m
Wollondilly DCP 2016, Volume 1, s 6.9 Menangle Landscape Conservation AreaR2 and R3 land in the Menangle Landscape Conservation Area (Wollondilly LEP 2011 Schedule 5, C6), chiefly the Station Street, Menangle release land.4.5m on lots up to 449.99m², 6m on larger lots0.9m3m2.5m on lots up to 899.99m², 3m on larger lots
Wollondilly DCP 2016, Volume 1, s 6.9 Menangle Landscape Conservation Area (rural zones)Rural and environmental zoned land in the Menangle Landscape Conservation Area (Wollondilly LEP 2011 Schedule 5, C6; mostly RU1 and RU2).4.5m on lots up to 449.99m², 6m on larger lots5m10m10m
Wilton Growth Area DCP 2021 (main body)s 1.1.4: "This DCP applies to land in the South East Wilton and North Wilton Precincts within the Wilton Growth Area as mapped in the Western Parkland City SEPP".no figure on lots up to 7.99m wide, 4.5m on wider lotsno figure on lots up to 7.99m wide, 0.9m on wider lots to one side, no figure on lots up to 7.99m wide, 0.9m on lots up to 15m wide, 1.5m on wider lots to the otherno figure on lots up to 7.99m wide, 4.5m on wider lotsno figure on lots up to 7.99m wide, 1m on lots up to 8.99m wide, 2m on wider lots
Show 4 more plans
Other plans in Wollondilly that cover a duplex, continued
PlanWhere it appliesFrontSideRearSecond street
Wilton Growth Area DCP 2021, Schedule 1 South East Wilton, Part 3 (Stage 1)Schedule 1 Part 3: "This Part applies to the Special Urban Area comprised of land within Stage 1 of the South East Wilton Precinct, as shown in orange / brown." Control 1: "Future development applications for low density residential dwellings located in Stage 1 of the South East Wilton Precinct ... are to be assessed against the summary of key controls as set out in this Section".no figure on lots up to 6.99m wide, 4.5m on wider lotsno figure on lots up to 6.99m wide, 0.9m on wider lots to one side, no figure on lots up to 6.99m wide, 0.9m on lots up to 15m wide, 0.9m on wider lots to the otherno figure on lots up to 6.99m wide, 4m on wider lotsno figure on lots up to 6.99m wide, 1m on lots up to 8.99m wide, 2m on wider lots
Wilton Growth Area DCP 2021, Schedule 2 North Wilton, Part 4 Savings Provisions (Stage 1)Schedule 2 Part 4: "This Part applies to the Stage 1 development area shown on Figure 3 Indicative Staging Plan in this schedule." It acknowledges DA 010.2019.00000617.001 (195 Fairway Drive, Wilton).no figure on lots up to 6.99m wide, 4.5m on wider lotsno figure on lots up to 6.99m wide, 0.9m on wider lots to one side, no figure on lots up to 6.99m wide, 0.9m on lots up to 15m wide, 0.9m on wider lots to the otherno figure on lots up to 6.99m wide, 4m on wider lotsno figure on lots up to 6.99m wide, 1m on lots up to 8.99m wide, 2m on wider lots
Wollondilly Greater Macarthur Growth Area DCP 2026 (Appin (Part) Precinct, Schedule 1)s 1.1.4: the DCP applies to the Appin (Part) Precinct (Schedule 1) and North Appin (Part) Precinct (Schedule 2) as mapped in the Western Parkland City SEPP; s 1.1.7: Wollondilly LEP 2011 and DCP 2016 no longer apply there.4.5m0.9m4.5m2m
Wollondilly Greater Macarthur Growth Area DCP 2026 (North Appin (Part) Precinct, Schedule 2)Schedule 2 s 1.1: "This Schedule applies to all development on the land in the North Appin (Part) Precinct shown in Figure 1 ... as shown on the Land Application Map." Read with the main body (Parts 1 to 7, https://www.planningportal.nsw.gov.au/sites/default/files/documents/2026/Wollondilly%20Greater%20Macarthur%20Growth%20Area%20Development%20Control%20Plan%20-%20Parts%201-7.pdf).4.5m0.9m4.5m2m

What are the complying development setbacks for a duplex?

If you build a duplex with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.

Complying development (CDC) setbacks for a duplex on three example lots
Example lotFrontSideRearCorner block, second street
450m² (15m wide, 30m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
600m² (15m wide, 40m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
1,000m² (20m wide, 50m deep)6.5m0.9m (1.5m at two storeys)5m (12m at two storeys)3m

What if my block is on a corner?

Wollondilly DCP 2016, Volume 4 Residential Development sets a separate setback for a duplex from the second street, the side street of a corner block: 2.5m on lots up to 899.99m², 3m on larger lots (Wollondilly DCP 2016, Vol 4, s 3.16 control 24). The complying development figure for the second street is in the CDC table above.

Does a two storey duplex need bigger setbacks?

Yes, under Wollondilly DCP 2016, Volume 4 Residential Development: the rear setback goes from 3m to 8m for the two storey part of the house; a single storey part may sit 3m from the rear. Under complying development, the two storey figures are in the CDC table above.

What else do people ask?

Can Wollondilly Council approve a duplex closer to the boundary?

It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.

Do these setbacks apply to a shed, pool or fence in Wollondilly?

No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.

When were the setbacks on this page checked?

We last read Wollondilly Council's plans on 11 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.

Where does this information come from?

These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.

What else can I check?

Check what applies to your block