How close to the boundary can a duplex be in Muswellbrook?
Muswellbrook Council's main plan, Muswellbrook DCP 2009, Section 6 Residential Development (R1, RU5), asks a single storey duplex for these setbacks: front the average of the neighbouring homes (4.5m where there are none); side 0.9m, plus 0.3m for every metre of wall above 3m; and rear 0.9m, plus 0.3m for every metre of wall above 3m.
In Muswellbrook the setbacks for a duplex come from Muswellbrook Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the duplex first.
NSW addresses only. Free, and no sign up.
What setbacks does Muswellbrook Council's main plan set for a duplex?
The table gives Muswellbrook DCP 2009, Section 6 Residential Development (R1, RU5)'s one and two storey figures and the clause each comes from. The plan covers this land: Residential development in the R1 General Residential and RU5 Village zones across Muswellbrook Shire (Muswellbrook, Denman, Sandy Hollow), including the West Denman (Section 27) and 9036 New England Highway (Section 29) urban release areas, which set no setbacks of their own, and the R1 land of the Ironbark Ridge Extension (Section 30).
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | the average of the neighbouring homes (4.5m where there are none) | the average of the neighbouring homes (4.5m where there are none) | Muswellbrook DCP 2009, Section 6, 6.1.2 Front Setbacks, controls (i) and (ii) |
| Side | 0.9m, plus 0.3m for every metre of wall above 3m | 0.9m, plus 0.3m for every metre of wall above 3m | Muswellbrook DCP 2009, Section 6, 6.1.3 Side and rear setbacks, control (i) |
| Rear | 0.9m, plus 0.3m for every metre of wall above 3m | 0.9m, plus 0.3m for every metre of wall above 3m | Muswellbrook DCP 2009, Section 6, 6.1.3 Side and rear setbacks, control (i) |
| Corner block, second street | no figure on lots up to 449.99m²; 2m on lots up to 600m²; 3m on lots up to 1,500m²; 5m on larger lots | no figure on lots up to 449.99m²; 2m on lots up to 600m²; 3m on lots up to 1,500m²; 5m on larger lots | Muswellbrook DCP 2009, Section 6, 6.1.2 Front Setbacks, control (ii), table row Corner allotment |
Which DCP applies to my block in Muswellbrook?
It depends on where the lot is. Muswellbrook DCP 2009, Section 6 Residential Development (R1, RU5) is Muswellbrook Council's main plan, and 2 other plans cover a duplex on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Muswellbrook DCP 2009, Section 6 Residential Development, New England Highway frontages | R1 house lots addressed to and abutting the New England Highway, which runs through Muswellbrook as Maitland Street, Bridge Street and Aberdeen Street. | the average of the neighbouring homes (10m where there are none) | 0.9m, plus 0.3m for every metre of wall above 3m | 0.9m, plus 0.3m for every metre of wall above 3m | no figure on lots up to 449.99m²; 2m on lots up to 600m²; 3m on lots up to 1,500m²; 5m on larger lots |
| Muswellbrook DCP 2009, Section 8 Rural and Environmental Zone Development (C3, W1) | C3 Environmental Management (E3 when the DCP was written) and W1 Natural Waterways land. | 50m | 10m | 10m | 50m |
What are the complying development setbacks for a duplex?
If you build a duplex with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 0.9m (1.5m at two storeys) | 5m (12m at two storeys) | 3m |
What if my block is on a corner?
Muswellbrook DCP 2009, Section 6 Residential Development (R1, RU5) sets a separate setback for a duplex from the second street, the side street of a corner block: no figure on lots up to 449.99m²; 2m on lots up to 600m²; 3m on lots up to 1,500m²; 5m on larger lots (Muswellbrook DCP 2009, Section 6, 6.1.2 Front Setbacks, control (ii), table row Corner allotment). Where the duplex faces that street, it asks for 5.5m for garage door, where driveway access is from the secondary frontage. The complying development figure for the second street is in the CDC table above.
Does a two storey duplex need bigger setbacks?
Yes, through the wall height: under Muswellbrook DCP 2009, Section 6 Residential Development (R1, RU5) the side and rear setback grows as the wall gets taller. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Muswellbrook Council approve a duplex closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Muswellbrook?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Muswellbrook Council's plans on 11 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.