Skip to main content

How close to the boundary can a duplex be in Ku-ring-gai?

Ku-ring-gai Council's main plan, Ku-ring-gai DCP, Parts 4, 4.1 and 5 (R2 land), asks a single storey duplex for these setbacks: front 12m; side 1.5m on lots up to 24.99m wide, 1.5m on lots up to 36m wide, 2.5m on wider lots; and rear 12m.

In Ku-ring-gai the setbacks for a duplex come from Ku-ring-gai Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the duplex first.

Check your address

NSW addresses only. Free, and no sign up.

What setbacks does Ku-ring-gai Council's main plan set for a duplex?

The table gives Ku-ring-gai DCP, Parts 4, 4.1 and 5 (R2 land)'s one and two storey figures and the clause each comes from. The plan covers this land: R2 Low Density Residential land in Ku-ring-gai outside the heritage conservation areas and the site parts below.

Ku-ring-gai DCP, Parts 4, 4.1 and 5 (R2 land): setbacks for a duplex
SetbackOne storeyTwo storeysWhere in the plan
Front12m12mKu-ring-gai DCP, Part 5A.3 Building Setbacks, Side-Side Dwelling Layout, control 6
Side1.5m on lots up to 24.99m wide, 1.5m on lots up to 36m wide, 2.5m on wider lots2m for the double storey elements on lots up to 24.99m wide, 2.5m for the double storey elements on lots up to 36m wide, 2.5m on wider lotsKu-ring-gai DCP, Part 5A.3 Building Setbacks, Side-Side Dwelling Layout, control 8
Rear12m12mKu-ring-gai DCP, Part 5A.3 Building Setbacks, Side-Side Dwelling Layout, control 7
Corner block, second street3m3mKu-ring-gai DCP, Part 5A.3 Building Setbacks, Corner Dwelling Layout, control 28

Which DCP applies to my block in Ku-ring-gai?

It depends on where the lot is. Ku-ring-gai DCP, Parts 4, 4.1 and 5 (R2 land) is Ku-ring-gai Council's main plan, and 7 other plans cover a duplex on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.

Other plans in Ku-ring-gai that cover a duplex
PlanWhere it appliesFrontSideRearSecond street
Ku-ring-gai DCP, Parts 4, 4.1, 5 and 19C (heritage conservation areas, R2 land)R2 land inside the KLEP 2015 heritage conservation areas (49 areas, C1 to C46, 659 ha).at least 14m, or the street's established building line where that is further back (at least 75% of the front elevation (up to 25% may come forward to the 12 m minimum))1m on lots up to 24.99m wide, 1.5m on lots up to 36m wide, 2.5m on wider lots8m on lots up to 48m deep, 12m on deeper lots3m
Ku-ring-gai DCP, Part 14H Screen Australia Site, LindfieldThe R2 house lots of the former Screen Australia site, 101 Eton Road, Lindfield (Lots 1 to 11 DP271066).9m1.5m on lots up to 24.99m wide, 1.5m on lots up to 36m wide, 2.5m on wider lots12m12m
Ku-ring-gai DCP, Part 14I Killara Golf Club, Area BArea B of the Killara Golf Club site (low density detached dwellings), the R2 part of Lot 2 DP535219.9m1.5m on lots up to 24.99m wide, 1.5m on lots up to 36m wide, 2.5m on wider lots12m3m
Ku-ring-gai DCP, Part 14M 47 Warrane Road, Roseville ChaseThe former East Roseville Bowling Club site, 47 Warrane Road, Roseville Chase (R2).6m1.5m on lots up to 24.99m wide, 1.5m on lots up to 36m wide, 2.5m on wider lots12m4.5m (at least half of the side street elevation (up to half may come to 3.8 m))
Ku-ring-gai DCP, Parts 4, 4.1 and 5 (Wahroonga Estate, R2 and R3 land)R2 and R3 land in the Wahroonga Estate (KLEP 2015 Schedule 1 item 44, Key Sites Map).12m1.5m on lots up to 24.99m wide, 1.5m on lots up to 36m wide, 2.5m on wider lots12m3m
Ku-ring-gai DCP, Parts 4, 4.1 and 5 (8 Church Street, Pymble)8 Church Street, Pymble (Lot 1A DP401840, C4), where KLEP 2015 Schedule 1 item 22 permits a detached dual occupancy.12m1.5m on lots up to 24.99m wide, 1.5m on lots up to 36m wide, 2.5m on wider lots12m3m
Ku-ring-gai DCP, Part 14J Holford Crescent, GordonThe R2 properties Part 14J lists along the unbuilt middle of Holford Crescent, Gordon (24-28 Holford Crescent / 58A Ryde Road, 52 and 46 Ryde Road, 36 Holford Crescent, 50, 52A, 54A, 56, 60, 64 and 66 Ridge Street).12m1.5m on lots up to 24.99m wide, 1.5m on lots up to 36m wide, 2.5m on wider lots20.23m3m

What are the complying development setbacks for a duplex?

If you build a duplex with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.

Complying development (CDC) setbacks for a duplex on three example lots
Example lotFrontSideRearCorner block, second street
450m² (15m wide, 30m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
600m² (15m wide, 40m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
1,000m² (20m wide, 50m deep)6.5m0.9m (1.5m at two storeys)5m (12m at two storeys)3m

What if my block is on a corner?

Ku-ring-gai DCP, Parts 4, 4.1 and 5 (R2 land) sets a separate setback for a duplex from the second street, the side street of a corner block: 3m (Ku-ring-gai DCP, Part 5A.3 Building Setbacks, Corner Dwelling Layout, control 28). Where the duplex faces that street, it asks for 6m. The complying development figure for the second street is in the CDC table above.

Does a two storey duplex need bigger setbacks?

Yes, under Ku-ring-gai DCP, Parts 4, 4.1 and 5 (R2 land): the side setback goes from 1.5m on lots up to 24.99m wide, 1.5m on lots up to 36m wide, 2.5m on wider lots to 2m for the double storey elements on lots up to 24.99m wide, 2.5m for the double storey elements on lots up to 36m wide, 2.5m on wider lots. Under complying development, the two storey figures are in the CDC table above.

What else do people ask?

Can Ku-ring-gai Council approve a duplex closer to the boundary?

It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.

Do these setbacks apply to a shed, pool or fence in Ku-ring-gai?

No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.

When were the setbacks on this page checked?

We last read Ku-ring-gai Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.

Where does this information come from?

These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.

What else can I check?

Check what applies to your block