How close to the boundary can a duplex be in Hilltops?
Hilltops Council's main plan, Hilltops DCP 2025, Sections 2.2 and 2.3 (residential, R1 and R2), asks a single storey duplex for these setbacks: front the average of the neighbouring homes (6m where there are none), side 3m and rear 3m.
In Hilltops the setbacks for a duplex come from Hilltops Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the duplex first.
NSW addresses only. Free, and no sign up.
What setbacks does Hilltops Council's main plan set for a duplex?
The table gives Hilltops DCP 2025, Sections 2.2 and 2.3 (residential, R1 and R2)'s one and two storey figures and the clause each comes from. The plan covers this land: Land zoned R1 General Residential or R2 Low Density Residential under Hilltops LEP 2022 (the towns of Young, Boorowa, Harden and Murrumburrah).
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | the average of the neighbouring homes (6m where there are none) | the average of the neighbouring homes (6m where there are none) | Hilltops DCP 2025, Section 2.3A MD2 AMD5.1 |
| Side | 3m | 4.09m for upper level | Hilltops DCP 2025, Section 2.3A MD2 PMD6.1 and Figure 7 |
| Rear | 3m | 4.09m for upper level | Hilltops DCP 2025, Section 2.3A MD2 PMD6.1 and Figure 7 |
| Corner block, second street | 3m | 3m | Hilltops DCP 2025, Section 2.3A MD2 AMD5.1 |
Which DCP applies to my block in Hilltops?
It depends on where the lot is. Hilltops DCP 2025, Sections 2.2 and 2.3 (residential, R1 and R2) is Hilltops Council's main plan, and 4 other plans cover a duplex on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Hilltops DCP 2025, Sections 2.2 and 2.3 (residential, R5 Large Lot Residential) | Land zoned R5 Large Lot Residential under Hilltops LEP 2022. | the average of the neighbouring homes (10m where there are none) | 10m | 10m | 6m |
| Hilltops DCP 2025, Sections 2.2C and 2.3D (dwellings in MU1 Mixed Use) | Land zoned MU1 Mixed Use under Hilltops LEP 2022 (the main streets of Young, Boorowa, Harden and Murrumburrah). | 50% of the lot depth, and at least 6m | 3m | 3m | 3m |
| Hilltops DCP 2025, Section 2.11 (Village Development, RU5) | Land zoned RU5 Village under Hilltops LEP 2022 (the villages). | 6m | 3m | not set by the DCP: ask the council | not set |
| Hilltops DCP 2025, Section 2.1 (Rural Dwellings, RU4 Primary Production Small Lots) | Land zoned RU4 Primary Production Small Lots under Hilltops LEP 2022. | 20m | 10m | 10m | 20m |
What are the complying development setbacks for a duplex?
If you build a duplex with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 0.9m (1.5m at two storeys) | 5m (12m at two storeys) | 3m |
What if my block is on a corner?
Hilltops DCP 2025, Sections 2.2 and 2.3 (residential, R1 and R2) sets a separate setback for a duplex from the second street, the side street of a corner block: 3m (Hilltops DCP 2025, Section 2.3A MD2 AMD5.1). The complying development figure for the second street is in the CDC table above.
Does a two storey duplex need bigger setbacks?
Yes, under Hilltops DCP 2025, Sections 2.2 and 2.3 (residential, R1 and R2): the side setback goes from 3m to 4.09m for upper level; the rear setback goes from 3m to 4.09m for upper level. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Hilltops Council approve a duplex closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Hilltops?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Hilltops Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.