Skip to main content

How close to the boundary can a duplex be in Goulburn Mulwaree?

Goulburn Mulwaree Council's main plan, Goulburn Mulwaree DCP 2009, Part 4 Principal development controls: urban, asks a single storey duplex for these setbacks: front 4.5m, side 1m and rear 6m.

In Goulburn Mulwaree the setbacks for a duplex come from Goulburn Mulwaree Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the duplex first.

Check your address

NSW addresses only. Free, and no sign up.

What setbacks does Goulburn Mulwaree Council's main plan set for a duplex?

The table gives Goulburn Mulwaree DCP 2009, Part 4 Principal development controls: urban's one and two storey figures and the clause each comes from. The plan covers this land: Land in Zones R1 General Residential, R2 Low Density Residential, E1 Local Centre and MU1 Mixed Use (Goulburn, Marulan and the villages' urban zones).

Goulburn Mulwaree DCP 2009, Part 4 Principal development controls: urban: setbacks for a duplex
SetbackOne storeyTwo storeysWhere in the plan
Front4.5m4.5mGoulburn Mulwaree DCP 2009, Part 4, s 4.1.10.3 Front setback
Side1m1mGoulburn Mulwaree DCP 2009, Part 4, s 4.1.10.2 Side setback
Rear6m6mGoulburn Mulwaree DCP 2009, Part 4, s 4.1.10.1 Rear setback
Corner block, second street3m3mGoulburn Mulwaree DCP 2009, Part 4, s 4.1.10.3 Front setback (corner allotments)

Which DCP applies to my block in Goulburn Mulwaree?

It depends on where the lot is. Goulburn Mulwaree DCP 2009, Part 4 Principal development controls: urban is Goulburn Mulwaree Council's main plan, and 4 other plans cover a duplex on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.

Other plans in Goulburn Mulwaree that cover a duplex
PlanWhere it appliesFrontSideRearSecond street
Goulburn Mulwaree DCP 2009, Part 5 Principal development controls: rural (Zone RU5 Village)Land in Zone RU5 Village (Marulan fringe, Tarago, Bungonia, Tallong and the other villages).5m1m6mnot set
Goulburn Mulwaree DCP 2009, Part 5 Principal development controls: rural (Zone R5 Large Lot Residential)Land in Zone R5 Large Lot Residential outside the Sooley and Mountain Ash precincts (those take Part 8 Chapters 8.13 and 8.14).20m1m6mnot set
Goulburn Mulwaree DCP 2009, Part 8, Chapter 8.13 Sooley Precinct (R5 land)R5 Large Lot Residential land in the Sooley Precinct, north west of Goulburn between the Wollondilly River and Crookwell Road (Figure 1).20m10m10mnot set
Goulburn Mulwaree DCP 2009, Part 8, Chapter 8.14 Mountain Ash Precinct (R5 land)R5 Large Lot Residential land in the Mountain Ash Precinct, bounded by Rosemont Road and the Hume Highway to the north and Windellama Road to the west (Figure 8-14-1).20m10m10mnot set

What are the complying development setbacks for a duplex?

If you build a duplex with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.

Complying development (CDC) setbacks for a duplex on three example lots
Example lotFrontSideRearCorner block, second street
450m² (15m wide, 30m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
600m² (15m wide, 40m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
1,000m² (20m wide, 50m deep)6.5m0.9m (1.5m at two storeys)5m (12m at two storeys)3m

What if my block is on a corner?

Goulburn Mulwaree DCP 2009, Part 4 Principal development controls: urban sets a separate setback for a duplex from the second street, the side street of a corner block: 3m (Goulburn Mulwaree DCP 2009, Part 4, s 4.1.10.3 Front setback (corner allotments)). The complying development figure for the second street is in the CDC table above.

Does a two storey duplex need bigger setbacks?

No. Goulburn Mulwaree DCP 2009, Part 4 Principal development controls: urban sets the same figures for a one or two storey duplex. Under complying development, the two storey figures are in the CDC table above.

What else do people ask?

Can Goulburn Mulwaree Council approve a duplex closer to the boundary?

It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.

Do these setbacks apply to a shed, pool or fence in Goulburn Mulwaree?

No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.

When were the setbacks on this page checked?

We last read Goulburn Mulwaree Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.

Where does this information come from?

These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.

What else can I check?

Check what applies to your block