Skip to main content

How close to the boundary can a duplex be in Eurobodalla?

Eurobodalla Council's main plan, Eurobodalla Residential Zones DCP (R2 and R3), asks a single storey duplex for these setbacks: front the average of the neighbouring homes (5.5m where there are none) on lots up to 2,499.99m²; 7m on lots up to 4,999.99m²; the average of the neighbouring homes (5.5m where there are none) on larger lots; side 0.9m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 0.9m on larger lots; and rear 3m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 3m on larger lots.

In Eurobodalla the setbacks for a duplex come from Eurobodalla Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the duplex first.

Check your address

NSW addresses only. Free, and no sign up.

What setbacks does Eurobodalla Council's main plan set for a duplex?

The table gives Eurobodalla Residential Zones DCP (R2 and R3)'s one and two storey figures and the clause each comes from. The plan covers this land: R2 Low Density Residential land across the shire except the Narooma and Moruya town plans (Maps 1 and 2), and R3 Medium Density Residential land on Maps 4 to 8 (Moruya Heads, River St Moruya, Kianga, The Brae, Tomakin).

Eurobodalla Residential Zones DCP (R2 and R3): setbacks for a duplex
SetbackOne storeyTwo storeysWhere in the plan
Frontthe average of the neighbouring homes (5.5m where there are none) on lots up to 2,499.99m²; 7m on lots up to 4,999.99m²; the average of the neighbouring homes (5.5m where there are none) on larger lotsthe average of the neighbouring homes (5.5m where there are none) on lots up to 2,499.99m²; 7m on lots up to 4,999.99m²; the average of the neighbouring homes (5.5m where there are none) on larger lotss 2.2 A2.1 and A2.3 (lots under 2500 m2); s 2.2 A1 (lots 2500 m2 to under 5000 m2)
Side0.9m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 0.9m on larger lots1.5m for any part of the building higher than 4.5m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 1.5m for any part of the building higher than 4.5m on larger lotss 2.2 A3 (lots under 2500 m2); s 2.2 A1 (lots 2500 m2 to under 5000 m2)
Rear3m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 3m on larger lots3m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 3m on larger lotss 2.2 A6.1 (lots under 2500 m2); s 2.2 A1 (lots 2500 m2 to under 5000 m2)
Corner block, second street3m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 3m on larger lots3m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 3m on larger lotss 2.2 A5.1 (lots under 2500 m2); s 2.2 A1 (lots 2500 m2 to under 5000 m2)

Which DCP applies to my block in Eurobodalla?

It depends on where the lot is. Eurobodalla Residential Zones DCP (R2 and R3) is Eurobodalla Council's main plan, and 14 other plans cover a duplex on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.

Other plans in Eurobodalla that cover a duplex
PlanWhere it appliesFrontSideRearSecond street
Moruya Township DCP, Precinct C (Residential)The residential Precinct C of the Moruya town centre (Map 1 and the precinct map): R3 and R2 land around Page, Queen and Campbell Streets, and the C4 land on Church Street.the average of the neighbouring homes (5.5m where there are none)0.9m3m3m
Narooma Township DCP (R2 and R3)R2 and R3 land inside the Narooma DCP boundary (Schedule 3 Maps 2 and 3): the town from Riverside Drive and Burrawang St south to Glasshouse Rocks Road.the average of the neighbouring homes (5.5m where there are none)0.9m3m3m
Eurobodalla Neighbourhood Centres DCP (R3 land)R3 land in the neighbourhood centres mapped in Schedule 3: Surfside and North Batemans Bay, Batehaven, Sunshine Bay and Denhams Beach, Surf Beach, Broulee (north of the reserve), Tuross Head and Dalmeny.the average of the neighbouring homes (5.5m where there are none)0.9m3m3m
Batemans Bay Regional Centre DCP (R3 Medium Density Residential Zone)The R3 land inside the Batemans Bay Regional Centre DCP Map 1 (the residential streets round the town centre from the Clyde bridge south-east to Beach Road, and the small R3 pocket at the northern tip of town beside the bridge).the average of the neighbouring homes (5.5m where there are none)0.9m3m3m
Bodalla Village DCP"That part of Bodalla village zoned RU5" (s 1.4).the average of the neighbouring homes (5.5m where there are none)0.9m3m3m
Nelligen Village DCP"The village of Nelligen as shown in Schedule 3" (s 1.4): the RU5 village.the average of the neighbouring homes (5.5m where there are none)0.9m3m3m
Tilba Villages and Conservation Area DCP: Central Tilba and Tilba TilbaThe villages of Central Tilba (Map 1: the RU5 village, 47 and 49 Corkhill Drive and the R5 land beside it) and Tilba Tilba (Map 2), except Lots 9 to 12 Section 4 DP 3166.at least not set, or the street's established building line where that is further backnot set by the DCP: ask the councilnot set by the DCP: ask the councilnot set
Tilba Villages and Conservation Area DCP: Lots 9 to 12 Section 4 DP 3166, Whiffens LaneLots 9, 10, 11 and 12 Section 4 DP 3166 on Whiffens Lane, Central Tilba (s 2.2 A2, Figure 2).5.5mnot set by the DCP: ask the council30mnot set
Show 6 more plans
Other plans in Eurobodalla that cover a duplex, continued
PlanWhere it appliesFrontSideRearSecond street
Tilba Villages and Conservation Area DCP: Tilba Conservation AreaRural land in the Tilba Conservation Area around Mount Dromedary (Gulaga), outside the two villages (DCP Map 3, Landscape Conservation Area; LEP Schedule 5 item C14).12m12m12m12m
Eurobodalla Residential Zones DCP (lots under 5000 m2) and Rural, R5 Large Lot Residential and E4 Environmental Living Zones DCP (5000 m2 and over)R5 Large Lot Residential and C4 Environmental Living (the DCPs' E4) land outside the town and village plans.the average of the neighbouring homes (5.5m where there are none) on lots up to 2,499.99m²; 7m on lots up to 4,999.99m²; 12m on larger lots0.9m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 12m on larger lots3m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 12m on larger lots3m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 12m on larger lots
Eurobodalla Residential Zones DCP (R5 and C4 with a minimum lot size under 2500 m2)R5 Large Lot Residential and C4 Environmental Living land whose LEP minimum lot size is under 2500 m2 (mostly 1500 m2: about 240 ha of C4, 80 ha of R5).the average of the neighbouring homes (5.5m where there are none) on lots up to 2,499.99m²; 7m on lots up to 4,999.99m²; the average of the neighbouring homes (5.5m where there are none) on larger lots0.9m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 0.9m on larger lots3m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 3m on larger lots3m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 3m on larger lots
Eurobodalla Residential Zones DCP (R5 and C4 with a 2500 m2 minimum lot size)R5 and C4 land whose LEP minimum lot size is 2500 m2 (two polygons, about 11 ha of C4).7m5m5m5m
Eurobodalla Residential Zones DCP: Lots 1 to 6 DP 708709, Congo Road, CongoLots 1 to 6 DP 708709, Congo Road, Congo (s 2.2 A9 and A10, Map 9 Congo Setbacks); zoned C4.15m0.9m on lots up to 2,499.99m²; 5m on larger lotsnot set by the DCP: ask the council3m on lots up to 2,499.99m²; 5m on larger lots
Eurobodalla Rural, R5 Large Lot Residential and E4 Environmental Living Zones DCP (RU1 and RU4)RU1 Primary Production and RU4 Primary Production Small Lots land (s 1.4), outside the Tilba Conservation Area.12m12m12m12m

What are the complying development setbacks for a duplex?

If you build a duplex with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.

Complying development (CDC) setbacks for a duplex on three example lots
Example lotFrontSideRearCorner block, second street
450m² (15m wide, 30m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
600m² (15m wide, 40m deep)4.5m0.9m (1.5m at two storeys)3m (8m at two storeys)2m
1,000m² (20m wide, 50m deep)6.5m0.9m (1.5m at two storeys)5m (12m at two storeys)3m

What if my block is on a corner?

Eurobodalla Residential Zones DCP (R2 and R3) sets a separate setback for a duplex from the second street, the side street of a corner block: 3m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 3m on larger lots (s 2.2 A5.1 (lots under 2500 m2); s 2.2 A1 (lots 2500 m2 to under 5000 m2)). Where the duplex faces that street, it asks for the average of the neighbouring homes (3m where there are none) on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; the average of the neighbouring homes (3m where there are none) on larger lots. The complying development figure for the second street is in the CDC table above.

Does a two storey duplex need bigger setbacks?

Yes, under Eurobodalla Residential Zones DCP (R2 and R3): the side setback goes from 0.9m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 0.9m on larger lots to 1.5m for any part of the building higher than 4.5m on lots up to 2,499.99m²; 5m on lots up to 4,999.99m²; 1.5m for any part of the building higher than 4.5m on larger lots. Under complying development, the two storey figures are in the CDC table above.

What else do people ask?

Can Eurobodalla Council approve a duplex closer to the boundary?

It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.

Do these setbacks apply to a shed, pool or fence in Eurobodalla?

No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.

When were the setbacks on this page checked?

We last read Eurobodalla Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.

Where does this information come from?

These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.

What else can I check?

Check what applies to your block