How close to the boundary can a duplex be in Cumberland?
Cumberland Council's main plan, Cumberland DCP 2021, Part B Development in Residential Zones, asks a single storey duplex for these setbacks: front the average of the neighbouring homes (4.5m on lots up to 900m²; 6.5m on lots up to 1,500m²; 10m on larger lots where there are none); side 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 24m wide; 1.5m, plus 0.25m for every metre of wall above 4.5m on lots up to 36m wide; 2.5m on wider lots; and rear 3m on lots up to 900m²; 5m on lots up to 1,500m²; 10m on larger lots.
In Cumberland the setbacks for a duplex come from Cumberland Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the duplex first.
NSW addresses only. Free, and no sign up.
What setbacks does Cumberland Council's main plan set for a duplex?
The table gives Cumberland DCP 2021, Part B Development in Residential Zones's one and two storey figures and the clause each comes from. The plan covers this land: Land zoned Residential under Cumberland LEP 2021 (Part B1 s 1.1: "This Part applies to development types detailed within this Part within land zoned Residential under Cumberland Local Environmental Plan 2021"); the LEP's residential zones are R2, R3 and R4 (NSW Planning Portal land zoning layer, Cumberland LEP 2021, read 2026-11-11).
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | the average of the neighbouring homes (4.5m on lots up to 900m²; 6.5m on lots up to 1,500m²; 10m on larger lots where there are none) | the average of the neighbouring homes (4.5m on lots up to 900m²; 6.5m on lots up to 1,500m²; 10m on larger lots where there are none) | Cumberland DCP 2021, Part B2, s 1.1, 2.1 and 2.2, adopting the Low Rise Housing Diversity Design Guide for Development Applications, s 2.1A Building Envelopes (Dual occupancy), design criteria |
| Side | 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 24m wide; 1.5m, plus 0.25m for every metre of wall above 4.5m on lots up to 36m wide; 2.5m on wider lots | 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 24m wide; 1.5m, plus 0.25m for every metre of wall above 4.5m on lots up to 36m wide; 2.5m on wider lots | Cumberland DCP 2021, Part B2, s 1.1, 2.1 and 2.2, adopting the Low Rise Housing Diversity Design Guide for Development Applications, s 2.1A Building Envelopes (Dual occupancy), design criteria |
| Rear | 3m on lots up to 900m²; 5m on lots up to 1,500m²; 10m on larger lots | 8m on lots up to 900m²; 12m on lots up to 1,500m²; 15m on larger lots | Cumberland DCP 2021, Part B2, s 1.1, 2.1 and 2.2, adopting the Low Rise Housing Diversity Design Guide for Development Applications, s 2.1A Building Envelopes (Dual occupancy), design criteria |
| Corner block, second street | 2m on lots up to 900m²; 3m on lots up to 1,500m²; 5m on larger lots | 2m on lots up to 900m²; 3m on lots up to 1,500m²; 5m on larger lots | Cumberland DCP 2021, Part B2, s 1.1, 2.1 and 2.2, adopting the Low Rise Housing Diversity Design Guide for Development Applications, s 2.1A Building Envelopes (Dual occupancy), design criteria |
Which DCP applies to my block in Cumberland?
It depends on where the lot is. Cumberland DCP 2021, Part B Development in Residential Zones is Cumberland Council's main plan, and 16 other plans cover a duplex on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Cumberland DCP 2021, Part F1-7 Former Lidcombe Hospital Site | F1-7 s 1.1: "This Part applies to land zoned R3 Medium Density Residential under the provisions of Cumberland LEP 2021 and known as the Former Lidcombe Hospital site, as shown in Figure 1 below." | 4m | 1.2m | 3m on lots up to 900m²; 5m on lots up to 1,500m²; 10m on larger lots | 2m on lots up to 900m²; 3m on lots up to 1,500m²; 5m on larger lots |
| Cumberland DCP 2021, Part F1-19 80 Betty Cuthbert Drive, Lidcombe | F1-19 s 1.2: "This section applies to the site referred to as 80 Betty Cuthbert Drive, containing the following three (3) lots: Lots 74 and 75 in DP 1141724 and Lot 475 in DP 45747. | 4m | 1.2m | 3m on lots up to 900m²; 5m on lots up to 1,500m²; 10m on larger lots | 2m on lots up to 900m²; 3m on lots up to 1,500m²; 5m on larger lots |
| Cumberland DCP 2021, Part F1-9 Greystanes Creek | F1-9 s 1.1: "This section applies to land situated in Cumberland City outlined in heavy black as shown on the plan map marked Figure 1. | the average of the neighbouring homes (4.5m on lots up to 900m²; 6.5m on lots up to 1,500m²; 10m on larger lots where there are none) | 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 24m wide; 1.5m, plus 0.25m for every metre of wall above 4.5m on lots up to 36m wide; 2.5m on wider lots | 10m | 2m on lots up to 900m²; 3m on lots up to 1,500m²; 5m on larger lots |
| Cumberland DCP 2021, Part F1-10 Guildford Pipehead Precinct | F1-10 s 1.1: "This part applies to the land shown on Figure 1 and known as the Guildford Pipehead Precinct." Sub-Precincts A, B and C on Figure 2 (Guildford West). | the average of the neighbouring homes (4.5m on lots up to 900m²; 6.5m on lots up to 1,500m²; 10m on larger lots where there are none) | 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 24m wide; 1.5m, plus 0.25m for every metre of wall above 4.5m on lots up to 36m wide; 2.5m on wider lots | 3m on lots up to 900m²; 5m on lots up to 1,500m²; 10m on larger lots | 2m on lots up to 900m²; 3m on lots up to 1,500m²; 5m on larger lots |
| Cumberland DCP 2021, Part F1-13 Holroyd Gardens | F1-13 s 1.1: "This Part applies to land known as "Holroyd Gardens", located adjacent to Walpole Street, the Main Southern Railway and Walpole Street Park, Holroyd. | 4.5m | 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 24m wide; 1.5m, plus 0.25m for every metre of wall above 4.5m on lots up to 36m wide; 2.5m on wider lots | 3m on lots up to 900m²; 5m on lots up to 1,500m²; 10m on larger lots | 2m on lots up to 900m²; 3m on lots up to 1,500m²; 5m on larger lots |
| Cumberland DCP 2021, Part F1-14 Pemulwuy Residential (Pemulwuy North) | F1-14 s 1.1: "Land to which this Part applies includes land identified as land within the residential precinct of Pemulwuy as shown in Figures 1 and 2." s 3.4: "The following controls apply specifically to the Pemulwuy precinct predominantly to the north of Butu Wargun as identified in Figure 1." | 4.5m | 0.9m | 6m | 1.5m |
| Cumberland DCP 2021, Part F1-14 Pemulwuy Residential (Pemulwuy South) | F1-14 s 1.1 (Figures 1 and 2) and s 3.5: "The following controls apply specifically to the Pemulwuy precinct predominantly to the south of Butu Wargun as identified in Figure 2." | 3m | 0.9m | 6m on lots up to 35m deep, 8m on deeper lots | 4m |
| Cumberland DCP 2021, Part F4-1 23-27 Lytton Street, Wentworthville | F4-1 s 1.1: "This section applies to the land at 23-27 Lytton Street, Wentworthville, being formally described as Lot 1 DP787784." Controls apply to "Any new building on the property". | 6m | 3m | 6m | 3m |
Show 8 more plans
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Cumberland DCP 2021, Part F4-3 Tamplin Road Reserve | F4-3 s 1.1: "This part applies to the land shown on Figure 1 and known as the Tamplin Road Reserve." s 2.1: "This section of the DCP applies to the western portion of the estate or Lot 10, as shown in Figure 2." (western part of the Linnwood Estate, Guildford, fronting Tamplin Road). | 6m | 1m | 4m | not set |
| Cumberland DCP 2021, Part F4-2 Transitway Precincts (lots with a 0 m front setback) | F4-2 s 1: "This Part of the DCP applies to all development within the Transitway Precincts of Mays Hill, Finlayson and Sherwood as shown in Figure 1." Within it, the residential zoned lots that the setback figures shade at 0 m: Mays Hill (Figures 10 and 11); Finlayson (Figures 18 and 19); Sherwood (Figure 23). | 0m | 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 24m wide; 1.5m, plus 0.25m for every metre of wall above 4.5m on lots up to 36m wide; 2.5m on wider lots | 3m on lots up to 900m²; 5m on lots up to 1,500m²; 10m on larger lots | 2m on lots up to 900m²; 3m on lots up to 1,500m²; 5m on larger lots |
| Cumberland DCP 2021, Part F4-2 Transitway Precincts (lots with a 3 m front setback) | F4-2 s 1: "This Part of the DCP applies to all development within the Transitway Precincts of Mays Hill, Finlayson and Sherwood as shown in Figure 1." Within it, the residential zoned lots that the setback figures shade at 3 m: Mays Hill (Figures 10 and 11); Finlayson (Figures 18 and 19); Sherwood (Figure 23). | 3m | 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 24m wide; 1.5m, plus 0.25m for every metre of wall above 4.5m on lots up to 36m wide; 2.5m on wider lots | 3m on lots up to 900m²; 5m on lots up to 1,500m²; 10m on larger lots | 2m on lots up to 900m²; 3m on lots up to 1,500m²; 5m on larger lots |
| Cumberland DCP 2021, Part F4-2 Transitway Precincts (lots with a 4 m front setback) | F4-2 s 1: "This Part of the DCP applies to all development within the Transitway Precincts of Mays Hill, Finlayson and Sherwood as shown in Figure 1." Within it, the residential zoned lots that the setback figures shade at 4 m: Mays Hill (Figures 10 and 11); Finlayson (Figures 18 and 19). | 4m | 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 24m wide; 1.5m, plus 0.25m for every metre of wall above 4.5m on lots up to 36m wide; 2.5m on wider lots | 3m on lots up to 900m²; 5m on lots up to 1,500m²; 10m on larger lots | 2m on lots up to 900m²; 3m on lots up to 1,500m²; 5m on larger lots |
| Cumberland DCP 2021, Part F4-2 Transitway Precincts (lots with a 5 m front setback) | F4-2 s 1: "This Part of the DCP applies to all development within the Transitway Precincts of Mays Hill, Finlayson and Sherwood as shown in Figure 1." Within it, the residential zoned lots that the setback figures shade at 5 m: Mays Hill (Figures 10 and 11); Finlayson (Figures 18 and 19); Sherwood (Figure 23). | 5m | 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 24m wide; 1.5m, plus 0.25m for every metre of wall above 4.5m on lots up to 36m wide; 2.5m on wider lots | 3m on lots up to 900m²; 5m on lots up to 1,500m²; 10m on larger lots | 2m on lots up to 900m²; 3m on lots up to 1,500m²; 5m on larger lots |
| Cumberland DCP 2021, Part F4-2 Transitway Precincts (lots with a 6 m front setback) | F4-2 s 1: "This Part of the DCP applies to all development within the Transitway Precincts of Mays Hill, Finlayson and Sherwood as shown in Figure 1." Within it, the residential zoned lots that the setback figures shade at 6 m: Mays Hill (Figures 10 and 11); Finlayson (Figures 18 and 19). | 6m | 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 24m wide; 1.5m, plus 0.25m for every metre of wall above 4.5m on lots up to 36m wide; 2.5m on wider lots | 3m on lots up to 900m²; 5m on lots up to 1,500m²; 10m on larger lots | 2m on lots up to 900m²; 3m on lots up to 1,500m²; 5m on larger lots |
| Cumberland DCP 2021, Part F4-4 Woodville Road Corridor (sites with a 10 m Woodville Road setback) | F4-4 s 1.1: "This Part applies to all development on land zoned R3 Medium Density Residential, R4 High Density Residential and E1 Local Centre within the Woodville Road Corridor (WRC) Boundary as shown in Figure 1, with the exception of the Merrylands East Precinct Key Site, which is the subject of separate site-specific planning controls (refer to Part F2-10)." Within it, the R3 and R4 lots of the planning proposal sites on Figures 6 (Woodville North), 7 (Merrylands East) and 8 (Woodville South) whose Woodville Road edge is marked 10 m. Other lots in the corridor have no F4-4 setback figure and take Part B. | 10m | 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 24m wide; 1.5m, plus 0.25m for every metre of wall above 4.5m on lots up to 36m wide; 2.5m on wider lots | 9m | 6m |
| Cumberland DCP 2021, Part F4-4 Woodville Road Corridor (sites with a 6 m Woodville Road setback) | F4-4 s 1.1: "This Part applies to all development on land zoned R3 Medium Density Residential, R4 High Density Residential and E1 Local Centre within the Woodville Road Corridor (WRC) Boundary as shown in Figure 1, with the exception of the Merrylands East Precinct Key Site, which is the subject of separate site-specific planning controls (refer to Part F2-10)." Within it, the R3 and R4 lots of the planning proposal sites on Figures 6 (Woodville North), 7 (Merrylands East) and 8 (Woodville South) whose Woodville Road edge is marked 6 m. Other lots in the corridor have no F4-4 setback figure and take Part B. | 6m | 0.9m, plus 0.25m for every metre of wall above 4.5m on lots up to 24m wide; 1.5m, plus 0.25m for every metre of wall above 4.5m on lots up to 36m wide; 2.5m on wider lots | 9m | 6m |
What are the complying development setbacks for a duplex?
If you build a duplex with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 0.9m (1.5m at two storeys) | 5m (12m at two storeys) | 3m |
What if my block is on a corner?
Cumberland DCP 2021, Part B Development in Residential Zones sets a separate setback for a duplex from the second street, the side street of a corner block: 2m on lots up to 900m²; 3m on lots up to 1,500m²; 5m on larger lots (Cumberland DCP 2021, Part B2, s 1.1, 2.1 and 2.2, adopting the Low Rise Housing Diversity Design Guide for Development Applications, s 2.1A Building Envelopes (Dual occupancy), design criteria). It measures the front setback from the shorter street frontage. The complying development figure for the second street is in the CDC table above.
Does a two storey duplex need bigger setbacks?
Yes, under Cumberland DCP 2021, Part B Development in Residential Zones: the rear setback goes from 3m on lots up to 900m²; 5m on lots up to 1,500m²; 10m on larger lots to 8m on lots up to 900m²; 12m on lots up to 1,500m²; 15m on larger lots. The side setback also grows as the wall gets taller. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Cumberland Council approve a duplex closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Cumberland?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Cumberland Council's plans on 11 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.