How close to the boundary can a house be in Wentworth?
Wentworth Council's main plan, Wentworth DCP 2011, Chapter 4 Residential Development Controls (RU5 Village), asks a single storey house for these setbacks: front the average of the neighbouring homes (6m where there are none); side 3.5m to one side, 1m to the other; and rear 3m.
In Wentworth the setbacks for a house come from Wentworth Council's development control plan (DCP), the council's own rules for the design of homes in its area, unless you build as complying development, which follows state rules instead. This page is a first look: enter your address and the Site Checker opens at the setbacks for your lot, with the house first.
NSW addresses only. Free, and no sign up.
What setbacks does Wentworth Council's main plan set for a house?
The table gives Wentworth DCP 2011, Chapter 4 Residential Development Controls (RU5 Village)'s one and two storey figures and the clause each comes from. The plan covers this land: Land zoned RU5 Village under Wentworth LEP 2011 (Wentworth, Dareton, Pooncarie, Curlwaa, Pomona and the Buronga and Gol Gol land outside the Chapter 8.1 urban release area map).
| Setback | One storey | Two storeys | Where in the plan |
|---|---|---|---|
| Front | the average of the neighbouring homes (6m where there are none) | the average of the neighbouring homes | Wentworth DCP 2011, Ch 4, s 4.1.3 Front Setback |
| One side | 3.5m | not set by the DCP: ask the council | Wentworth DCP 2011, Ch 4, s 4.1.4 Side setbacks and Corner Lot Setbacks |
| Other side | 1m | not set by the DCP: ask the council | Wentworth DCP 2011, Ch 4, s 4.1.4 Side setbacks and Corner Lot Setbacks |
| Rear | 3m | 6.5m for the second storey component of the development | Wentworth DCP 2011, Ch 4, s 4.1.5 Rear setbacks |
| Corner block, second street | 4m | 4m | Wentworth DCP 2011, Ch 4, s 4.1.3 Front Setback |
Which DCP applies to my block in Wentworth?
It depends on where the lot is. Wentworth DCP 2011, Chapter 4 Residential Development Controls (RU5 Village) is Wentworth Council's main plan, and 14 other plans cover a house on particular land, such as a precinct, an estate, rural land or a former council area. Many councils have several plans, set by zone, estate, precinct or former council area, so enter your address and the Site Checker picks the plan that covers your lot. The table lists each plan with its one storey figures.
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Wentworth DCP 2011, Chapters 4 and 5 (R5 Large Lot Residential) | Land zoned R5 Large Lot Residential under Wentworth LEP 2011. | 15m | 3.5m to one side, 1m to the other | 3m | 4m |
| Wentworth DCP 2011, Chapter 5 Rural Development Controls (RU1, 10,000 ha lot size area) | Land zoned RU1 Primary Production where the Lot Size Map shows 10,000 ha (almost all of the RU1 land). | 50m | 3.5m to one side, 1m to the other | 3m | 4m |
| Wentworth DCP 2011, Chapter 5 Rural Development Controls (RU1, 10 ha lot size area) | Land zoned RU1 Primary Production where the Lot Size Map shows 10 ha (only slivers of RU1 today). | 15m | 3.5m to one side, 1m to the other | 3m | 4m |
| Wentworth DCP 2011, Chapters 4 and 5 (RU1 outside the 10,000 ha and 10 ha lot size areas) | Land zoned RU1 Primary Production that is in neither the 10,000 ha nor the 10 ha Lot Size Map area (about 20 ha at 5,000 m2 and about 970 ha with no lot size, by area intersection of the zoning and Lot Size Map layers on 2026-11-12). | not set by the DCP: ask the council | 3.5m to one side, 1m to the other | 3m | 4m |
| Wentworth DCP 2011, Chapter 5 Rural Development Controls (RU4) | Land zoned RU4 (Rural Small Holdings in the DCP; Primary Production Small Lots in the LEP). | 15m | 3.5m to one side, 1m to the other | 3m | 4m |
| Wentworth DCP 2011, Chapter 4 Residential Development Controls (C3 and C4) | Land zoned C3 Environmental Management or C4 Environmental Living. | not set by the DCP: ask the council | 3.5m to one side, 1m to the other | 3m | 4m |
| Wentworth DCP 2011, Chapter 4 Residential Development Controls (E1 and E3, dwelling houses) | Land zoned E1 Local Centre or E3 Productivity Support outside the Buronga and Gol Gol urban release area. | not set by the DCP: ask the council | 3.5m to one side, 1m to the other | 3m | 4m |
| Wentworth DCP 2011, Chapter 4 Residential Development Controls (SP1 Community facilities, dwelling houses) | Land zoned SP1 Special Activities marked "Community facilities" (one 76.9 ha parcel), where LEP Schedule 1 item 5(2) reads "Development for the purposes of dwelling houses or educational establishments is permitted with development consent." | not set by the DCP: ask the council | 3.5m to one side, 1m to the other | 3m | 4m |
Show 6 more plans
| Plan | Where it applies | Front | Side | Rear | Second street |
|---|---|---|---|---|---|
| Wentworth DCP 2011, Chapter 8.1 Buronga and Gol Gol (RU5) | RU5 Village land inside the Buronga and Gol Gol urban release area on Map to Clause 8.1. | the average of the neighbouring homes (6m where there are none) | 3.5m to one side, 1m to the other | 3m | 4m |
| Wentworth DCP 2011, Chapter 8.1 Buronga and Gol Gol (E1, dwelling houses) | E1 Local Centre land inside the Buronga and Gol Gol urban release area on Map to Clause 8.1 (5 lots). | not set by the DCP: ask the council | 3.5m to one side, 1m to the other | 3m | 4m |
| Wentworth DCP 2011, Chapter 8.1 Buronga and Gol Gol (RU1) | RU1 Primary Production land inside the Buronga and Gol Gol urban release area on Map to Clause 8.1 (2 lots, 90//DP756946 and 83//DP756946). | not set by the DCP: ask the council | 3.5m to one side, 1m to the other | 3m | 4m |
| Wentworth DCP 2011, Chapter 8.1 Buronga and Gol Gol (RU4) | RU4 Primary Production Small Lots land inside the Buronga and Gol Gol urban release area outline (part of 453//DP1217477, which the Map 8.1 line crosses). | not set by the DCP: ask the council | 3.5m to one side, 1m to the other | 3m | 4m |
| Wentworth DCP 2011, Chapter 8.2 Wentworth Aerodrome Residential (Lot 1 estate) | The Lot 1 estate beside Wentworth Aerodrome on Old Renmark Road: "Lot 1 has been subdivided into eight lots, each containing approximately 0.8 ha." These are Lots 1 to 8 DP870517 today, zoned RU1 (houses, granny flats and attached duplexes permitted). | 20m | 5m | not set by the DCP: ask the council | not set |
| Wentworth DCP 2011, Chapter 8.2 Wentworth Aerodrome Residential (Lot 2 estate) | The Lot 2 estate beside Wentworth Aerodrome (Lot 2 DP 819579, since subdivided into Lots 1 to 11 DP1302054), zoned RU1. | not set by the DCP: ask the council | not set by the DCP: ask the council | not set by the DCP: ask the council | not set |
What are the complying development setbacks for a house?
If you build a house with a complying development certificate (CDC), the fast approval a private certifier can issue when a design meets the state's fixed standards, the setbacks come from the state codes, not from the council's DCP, and they depend on the lot's area and width. The table shows the complying development (CDC) figures the Site Checker uses for three example lots: 450m² (15m wide, 30m deep), 600m² (15m wide, 40m deep) and 1,000m² (20m wide, 50m deep). Your own lot's figures are in its report, and Can I use complying development on my block? explains which lots qualify.
| Example lot | Front | Side | Rear | Corner block, second street |
|---|---|---|---|---|
| 450m² (15m wide, 30m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 600m² (15m wide, 40m deep) | 4.5m | 0.9m (1.5m at two storeys) | 3m (8m at two storeys) | 2m |
| 1,000m² (20m wide, 50m deep) | 6.5m | 1.5m (2.1m at two storeys) | 5m (12m at two storeys) | 3m |
What if my block is on a corner?
Wentworth DCP 2011, Chapter 4 Residential Development Controls (RU5 Village) sets a separate setback for a house from the second street, the side street of a corner block: 4m (Wentworth DCP 2011, Ch 4, s 4.1.3 Front Setback). Where the house faces that street, it asks for 4.5m. On a corner block it also changes the other boundaries: side 2m for one storey, not set for two storeys and other side 2m for one storey, not set for two storeys. The complying development figure for the second street is in the CDC table above.
Does a two storey house need bigger setbacks?
Yes, under Wentworth DCP 2011, Chapter 4 Residential Development Controls (RU5 Village): the front setback goes from the average of the neighbouring homes (6m where there are none) to the average of the neighbouring homes; the one side setback goes from 3.5m to not set by the DCP: ask the council; the other side setback goes from 1m to not set by the DCP: ask the council; the rear setback goes from 3m to 6.5m for the second storey component of the development. Under complying development, the two storey figures are in the CDC table above.
What else do people ask?
Can Wentworth Council approve a house closer to the boundary?
It can. A development application (DA) is assessed on its merits, so the council can accept less than its plan asks for where a design justifies it, or ask for more. A complying development certificate has no such room: the design meets the code's setbacks or it is not complying development.
Do these setbacks apply to a shed, pool or fence in Wentworth?
No. Sheds, pergolas, carports, pools, decks and fences follow different rules (exempt development, which needs no approval when it meets them), and these pages do not cover them.
When were the setbacks on this page checked?
We last read Wentworth Council's plans on 12 November 2026. Each figure names the clause it came from, and each plan links to the council's own document, so you can check it against the current version.
Where does this information come from?
These pages are a first look at the setbacks in each council's published development control plan and in the complying development codes, read from the documents linked on each page. They are not a section 10.7 planning certificate or a design check, and a council plan can change after we read it. Confirm anything you rely on with the council or a certifier before you buy, design or build. Nothing on this page replaces advice from your certifier, engineer, lawyer or your own designer.