Skip to main content

99 Manning Road Woollahra NSW 2025

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 2,500 litre rainwater tank.

Key features

Windows
23 windows and glazed doors: Aluminium A DG Air Fill High Solar Gain low-E -Clear; Aluminium B DG Air Fill High Solar Gain low-E -Clear
Wall insulation
All external walls foil-foam composite board
Roof and ceiling insulation
Roof Added insulation absorptance Roof Colour SLAB-100-CEIL-01: Concrete Slab (100mm) with Suspended PB Ceiling 0.00, medium colour
Hot water
Gas instantaneous with a performance of 7 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
72 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
14 MJ/m² a year
Cooling load
16 MJ/m² a year
Bedrooms
3
Conditioned floor area
241 m²
Unconditioned floor area
5 m²
Site area
424 m²
Roof area
204 m²
Garden area
152 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 7 stars
Rainwater tank
2,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 111 m², double glazing 111 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (foil-foam composite board)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (foil-foam composite board)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: cavity brick; frame: no frame. all external walls foil-foam composite board
  • External garage wall: concrete block/plasterboard; frame: no frame (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: none.)

Certificate 1774559S_03, issued 8 October 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
Hero 4.1
Rated on
08 Oct 2025
Living room glazing by direction
N 15.8 m², E 12.2 m², S 3.4 m², W 15.6 m²
All glazing by direction
N 32.8 m², NNE 0.5 m², NE 1.8 m², ENE 0.9 m², E 34.5 m², S 18.3 m², W 23.7 m²

Roof

  • Added insulation absorptance Roof Colour SLAB-100-CEIL-01: Concrete Slab (100mm) with Suspended PB Ceiling 0.00, medium colour

Window types

  • ALM-003-03 A Aluminium A DG Air Fill High Solar Gain low-E -Clear: U-value 4.3, SHGC 0.47
  • ALM-004-03 A Aluminium B DG Air Fill High Solar Gain low-E -Clear: U-value 4.3, SHGC 0.53

Window schedule

  • B3 Ens, window ALM-004-03 A: 2,700 × 300 mm facing W
  • Bed 4, window ALM-004-03 A: 2,700 × 2,400 mm facing N
  • Bedroom 1, window ALM-004-03 A: 3,050 × 2,700 mm facing E
  • Bedroom 3, window ALM-003-03 A: 2,700 × 600 mm facing S
  • Bedroom 3, window ALM-004-03 A: 2,700 × 2,700 mm facing W
  • Bedroom 3, window ALM-004-03 A: 2,700 × 2,400 mm facing N
  • FF Corridor, window ALM-004-03 A: 2,700 × 1,000 mm facing N
  • FF Corridor, window ALM-004-03 A: 2,700 × 187 mm facing NNE
  • FF Corridor, window ALM-004-03 A: 2,700 × 438 mm facing NE
  • FF Corridor, window ALM-004-03 A: 2,700 × 223 mm facing NE
  • FF Corridor, window ALM-004-03 A: 2,700 × 330 mm facing ENE
  • FF Corridor, window ALM-003-03 A: 2,700 × 3,800 mm facing S
  • GF Bath, window ALM-003-03 A: 2,400 × 600 mm facing S
  • Kitchen/Living, window ALM-004-03 A: 2,700 × 3,800 mm facing N
  • Kitchen/Living, window ALM-004-03 A: 600 × 2,000 mm facing S
  • Kitchen/Living, window ALM-003-03 A: 2,400 × 900 mm facing S
  • Kitchen/Living, window ALM-004-03 A: 3,050 × 5,100 mm facing W
  • Lounge/Foyer, window ALM-004-03 A: 3,050 × 1,800 mm facing N
  • Lounge/Foyer, window ALM-004-03 A: 3,050 × 4,000 mm facing E
  • Master Bedroom, window ALM-004-03 A: 2,700 × 3,500 mm facing E
  • Master Ens, window ALM-003-03 A: 2,700 × 1,700 mm facing E
  • Master Ens, window ALM-004-03 A: 900 × 1,500 mm facing N
  • WIR, window ALM-003-03 A: 2,700 × 600 mm facing S

Certificate HR-CWD15B-03, issued 8 October 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

NatHERS certificate, certificate HR-CWD15B-02, issued 30 May 2025

NatHERS certificate

Star rating
7 stars
Rated with
Hero 4.1
Rated on
30 May 2025
Living room glazing by direction
N 22.2 m², E 13.8 m², S 3.4 m², W 15.6 m²
All glazing by direction
N 35.5 m², NNE 0.9 m², NE 1.9 m², ENE 0.9 m², E 33.1 m², S 18.3 m², W 23.7 m²

Roof

  • Added insulation absorptance Roof Colour SLAB-100-CEIL-01: Concrete Slab (100mm) with Suspended PB Ceiling 0.00, medium colour

Window types

  • ATB-003-03 B Al Thermally Broken A DG Air Fill High Solar Gain low-E - Clear: U-value 3.1, SHGC 0.39
  • ATB-004-03 B Al Thermally Broken B DG Air Fill High Solar Gain low-E - Clear: U-value 3.1, SHGC 0.49

Window schedule

  • B3 Ens, window ATB-004-03 B: 2,700 × 300 mm facing W
  • Bedroom 1, window ATB-004-03 B: 3,050 × 2,700 mm facing E
  • Bedroom 3, window ATB-003-03 B: 2,700 × 600 mm facing S
  • Bedroom 3, window ATB-004-03 B: 2,700 × 2,700 mm facing W
  • Bedroom 3, window ATB-004-03 B: 2,700 × 2,400 mm facing N
  • Kitchen/Living, window ATB-004-03 B: 2,700 × 2,400 mm facing N
  • FF Study/Corridor, window ATB-004-03 B: 2,700 × 1,000 mm facing N
  • FF Study/Corridor, window ATB-004-03 B: 2,700 × 328 mm facing NNE
  • FF Study/Corridor, window ATB-004-03 B: 2,700 × 498 mm facing NE
  • FF Study/Corridor, window ATB-004-03 B: 2,700 × 223 mm facing NE
  • FF Study/Corridor, window ATB-004-03 B: 2,700 × 330 mm facing ENE
  • FF Study/Corridor, window ATB-004-03 B: 2,700 × 1,500 mm facing N
  • FF Study/Corridor, window ATB-003-03 B: 2,700 × 3,800 mm facing S
  • GF Bath, window ATB-003-03 B: 2,400 × 600 mm facing S
  • Kitchen/Living, window ATB-004-03 B: 2,700 × 3,800 mm facing N
  • Kitchen/Living, window ATB-004-03 B: 600 × 2,000 mm facing S
  • Kitchen/Living, window ATB-003-03 B: 2,400 × 900 mm facing S
  • Kitchen/Living, window ATB-004-03 B: 3,050 × 5,100 mm facing W
  • Lounge/Foyer, window ATB-003-03 B: 2,700 × 600 mm facing E
  • Lounge/Foyer, window ATB-004-03 B: 3,050 × 1,800 mm facing N
  • Lounge/Foyer, window ATB-004-03 B: 3,050 × 4,000 mm facing E
  • Master Bedroom, window ATB-003-03 B: 2,700 × 600 mm facing E
  • Master Bedroom, window ATB-004-03 B: 2,700 × 3,500 mm facing E
  • WIR, window ATB-003-03 B: 2,700 × 600 mm facing S

Certificate HR-CWD15B-02, issued 30 May 2025, from the council's DA documents. Verify this certificate

BASIX certificate, certificate 1774559S_02, issued 30 May 2025

BASIX certificate

Energy score
72 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
17 MJ/m² a year
Cooling load
12 MJ/m² a year
Bedrooms
3
Conditioned floor area
241 m²
Unconditioned floor area
5 m²
Site area
424 m²
Roof area
204 m²
Garden area
152 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 7 stars
Rainwater tank
2,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 111 m², double glazing 111 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (foil-foam composite board)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (foil-foam composite board)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: cavity brick; frame: no frame. all external walls foil-foam composite board
  • External garage wall: concrete block/plasterboard; frame: no frame (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: none.)

Certificate 1774559S_02, issued 30 May 2025, from the council's DA documents.

NatHERS certificate, certificate HR-CWD15B-01, issued 25 November 2024

NatHERS certificate

Star rating
7 stars
Rated with
Hero 4.1
Rated on
25 Nov 2024
Living room glazing by direction
N 19.3 m², E 12.2 m², S 3.4 m², W 15.6 m²
All glazing by direction
N 32.5 m², NNE 0.9 m², NE 1.9 m², ENE 0.9 m², E 33.1 m², S 18.3 m², W 23.7 m²

Roof

  • Added insulation absorptance Roof Colour SLAB-100-CEIL-01: Concrete Slab (100mm) with Suspended PB Ceiling 0.00, medium colour

Window types

  • ATB-003-03 B Al Thermally Broken A DG Air Fill High Solar Gain low-E - Clear: U-value 3.1, SHGC 0.39
  • ATB-004-03 B Al Thermally Broken B DG Air Fill High Solar Gain low-E - Clear: U-value 3.1, SHGC 0.49

Window schedule

  • B3 Ens, window ATB-003-03 B: 2,700 × 300 mm facing W
  • Bedroom 1, window ATB-004-03 B: 3,050 × 2,700 mm facing E
  • Bedroom 3, window ATB-003-03 B: 2,700 × 600 mm facing S
  • Bedroom 3, window ATB-004-03 B: 2,700 × 2,700 mm facing W
  • Bedroom 3, window ATB-004-03 B: 2,700 × 2,400 mm facing N
  • Kitchen/Living, window ATB-004-03 B: 2,700 × 2,400 mm facing N
  • FF Study/Corridor, window ATB-004-03 B: 2,700 × 1,000 mm facing N
  • FF Study/Corridor, window ATB-004-03 B: 2,700 × 328 mm facing NNE
  • FF Study/Corridor, window ATB-004-03 B: 2,700 × 498 mm facing NE
  • FF Study/Corridor, window ATB-004-03 B: 2,700 × 223 mm facing NE
  • FF Study/Corridor, window ATB-004-03 B: 2,700 × 330 mm facing ENE
  • FF Study/Corridor, window ATB-004-03 B: 2,700 × 1,500 mm facing N
  • FF Study/Corridor, window ATB-003-03 B: 2,700 × 3,800 mm facing S
  • GF Bath, window ATB-003-03 B: 2,400 × 600 mm facing S
  • Kitchen/Living, window ATB-004-03 B: 3,050 × 2,400 mm facing N
  • Kitchen/Living, window ATB-004-03 B: 600 × 2,000 mm facing S
  • Kitchen/Living, window ATB-003-03 B: 2,400 × 900 mm facing S
  • Kitchen/Living, window ATB-004-03 B: 3,050 × 5,100 mm facing W
  • Lounge/Foyer, window ATB-004-03 B: 3,050 × 1,800 mm facing N
  • Lounge/Foyer, window ATB-004-03 B: 3,050 × 4,000 mm facing E
  • Master Bedroom, window ATB-003-03 B: 2,700 × 600 mm facing E
  • Master Bedroom, window ATB-004-03 B: 2,700 × 3,500 mm facing E
  • Master Ens, window ATB-003-03 B: 2,700 × 600 mm facing E
  • WIR, window ATB-003-03 B: 2,700 × 600 mm facing S

Certificate HR-CWD15B-01, issued 25 November 2024, from the council's DA documents. Verify this certificate

BASIX certificate, certificate 1774559S, issued 25 November 2024

BASIX certificate

Energy score
72 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
18 MJ/m² a year
Cooling load
12 MJ/m² a year
Bedrooms
3
Conditioned floor area
241 m²
Unconditioned floor area
5 m²
Site area
424 m²
Roof area
204 m²
Garden area
152 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 7 stars
Rainwater tank
2,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 111 m², double glazing 111 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (foil-foam composite board)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (foil-foam composite board)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: cavity brick; frame: no frame. all external walls foil-foam composite board
  • External garage wall: concrete block/plasterboard; frame: no frame (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: none.)

Certificate 1774559S, issued 25 November 2024, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related