9 Beresford Crescent Bellevue Hill NSW 2023
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 1.6 kW of solar panels and a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 43 against 40.
Key features
- Windows
- 32 windows and glazed doors: Al Thermally Broken B DG Argon Fill High Solar Gain low-E -Clear; 325 High Fixed Window-TPS 4/14Ar/4TiPS; 600 Series Sliding Door w/ Foam Infill-TPS 4LE272/12Ar/4/12Ar/4LE272
- Wall insulation
- R2.0
- Roof and ceiling insulation
- Ceiling R2.0, R4.0, R1.0, roof Slab:Slab - Suspended Slab : 200mm: 200mm Suspended Slab 0.0, medium colour
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- Airconditioning ducting only (living area and bedroom)
Built by Attena Group.
BASIX certificate
- Energy score
- 72 (target 72)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 18 MJ/m² a year
- Cooling load
- 12 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 232.5 m²
- Unconditioned floor area
- 2.6 m²
- Site area
- 525 m²
- Roof area
- 140 m²
- Garden area
- 129 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 1.6 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Maximum glazing
- uPVC frames 81.6 m², aluminium frames 76.1 m², double glazing 118 m², triple glazing 39.8 m²
Heating
- Living area: airconditioning ducting only; Energy rating: n/a
- Bedroom: airconditioning ducting only; Energy rating: n/a
Cooling
- Living area: airconditioning ducting only; Energy rating: n/a
- Bedroom: airconditioning ducting only; Energy rating: n/a
Construction and insulation
- Floor: concrete slab on ground, conventional slab (polystyrene)
- Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (polystyrene)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
- Floor: suspended floor above garage, concrete - suspended; frame: no frame (polystyrene)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: AAC veneer; frame: timber - untreated softwood (polystyrene)
- External wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (polyurethane)
- External garage wall: concrete block/plasterboard; frame: please select (not specified)
- Internal wall: single skin masonry; frame: no frame (polystyrene)
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, concrete - plasterboard internal, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: none.)
Certificate 1163808S_06, issued 10 February 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 7 Feb 2025
- Wall insulation
- R2.0
- Ceiling insulation
- R2.0, R4.0, R1.0
- Floor insulation
- R4.30, R2.0, R1.0
- Living room glazing by direction
- NE 6.7 m², SE 15.3 m², SW 1.5 m², NW 14.1 m²
- All glazing by direction
- NE 41.8 m², SE 59.1 m², SW 5.9 m², NW 50.9 m²
Roof
- Slab:Slab - Suspended Slab : 200mm: 200mm Suspended Slab 0.0, medium colour
Window types
- ATB-006-03 B Al Thermally Broken B DG Argon Fill High Solar Gain low-E -Clear: U-value 2.9, SHGC 0.51
- SOV-002-11 W 325 High Fixed Window-TPS 4/14Ar/4TiPS: U-value 1.38, SHGC 0.46
- SOV-010-12 W 600 Series Sliding Door w/ Foam Infill-TPS 4LE272/12Ar/4/12Ar/4LE272: U-value 1.08, SHGC 0.27
Window schedule
- BASE HALL, window SOV-002-11 W: 2,400 × 900 mm facing NW
- BASE HALL, window SOV-002-11 W: 2,400 × 900 mm facing NW
- LOUNGE, window SOV-010-12 W: 2,770 × 3,400 mm facing NW
- LOUNGE, window SOV-002-11 W: 600 × 2,500 mm facing SW
- LOUNGE, window SOV-010-12 W: 2,770 × 3,600 mm facing SE
- KLD, window ATB-006-03 B: 2,700 × 3,200 mm facing NW
- KLD, window ATB-006-03 B: 2,700 × 3,700 mm facing SE
- KLD, window ATB-006-03 B: 2,700 × 3,700 mm facing NE
- KLD, window SOV-002-11 W: 1,470 × 1,880 mm facing NE
- ENTRY, window SOV-002-11 W: 2,900 × 900 mm facing NW
- ENTRY, window SOV-002-11 W: 2,900 × 900 mm facing NW
- ES1, window SOV-002-11 W: 2,770 × 800 mm facing NW
- WIR1, window SOV-002-11 W: 500 × 1,370 mm facing NE
- WIR1, window SOV-002-11 W: 2,770 × 800 mm facing NW
- MB1, window ATB-006-03 B: 2,770 × 3,700 mm facing SE
- MB1, window ATB-006-03 B: 2,770 × 3,700 mm facing NE
- VOID 1 F, window SOV-002-11 W: 3,000 × 1,100 mm facing SE
- VOID 2 F, window SOV-002-11 W: 2,900 × 900 mm facing NW
- VOID 2 F, window SOV-002-11 W: 2,100 × 900 mm facing NW
- B3, window ATB-006-03 B: 2,770 × 2,800 mm facing NW
- ES3, window SOV-002-11 W: 2,770 × 800 mm facing SW
- ES2, window SOV-002-11 W: 2,770 × 800 mm facing SW
- B2, window SOV-010-12 W: 2,770 × 3,650 mm facing SE
- B2, window SOV-010-12 W: 2,770 × 3,700 mm facing NE
- VOID 1 S, window SOV-002-11 W: 2,700 × 1,100 mm facing SE
- ES4, window SOV-002-11 W: 2,350 × 800 mm facing NW
- B4, window ATB-006-03 B: 2,500 × 2,900 mm facing SE
- B4, window SOV-002-11 W: 2,350 × 500 mm facing NE
- UPPER LIVING, window ATB-006-03 B: 2,400 × 2,200 mm facing SE
- UPPER LIVING, window ATB-006-03 B: 2,400 × 2,800 mm facing NE
- UPPER LIVING, window SOV-002-11 W: 2,600 × 900 mm facing NW
- UPPER LIVING, window SOV-002-11 W: 2,600 × 900 mm facing NW
Certificate TZ2Q64YM9F, issued 7 February 2025, from the council's DA documents. Verify this certificate
Other certificates for this address
NatHERS certificate, certificate 6HTX47T3BE, issued 22 November 2022
NatHERS certificate
- Star rating
- 5 stars
- Rated with
- FirstRate5: 5.3.2b (3.21)
- Rated on
- 22 Nov 2022
- Ceiling insulation
- R1.0, R2.0
- Floor insulation
- R1.0
- Living room glazing by direction
- NNE 8.4 m², ESE 15.5 m², SSW 2.4 m², WNW 17.1 m²
- All glazing by direction
- NNE 48.5 m², ESE 65.3 m², SSW 8.5 m², WNW 62.9 m²
Roof
- Disc:Attic-Discontinuous 0.0, medium colour
- Slab:Slab - Suspended Slab : 200mm: 200mm Suspended Slab 0.0, medium colour
Window types
- ATB-004-01 B Al Thermally Broken B DG Air Fill Clear-Clear: U-value 3.6, SHGC 0.54
- ATB-006-03 B Al Thermally Broken B DG Argon Fill High Solar Gain low-E -Clear: U-value 2.9, SHGC 0.51
- ATB-006-04 B Al Thermally Broken B DG Argon Fill Low Solar Gain low-E -Clear: U-value 3, SHGC 0.26
Window schedule
- TV ROOM, window ATB-004-01 B: 600 × 1,800 mm facing ESE
- TV ROOM, window ATB-004-01 B: 600 × 1,800 mm facing NNE
- BASE HALL, window ATB-004-01 B: 1,600 × 2,700 mm facing WNW
- LOUNGE, window ATB-004-01 B: 2,800 × 3,600 mm facing WNW
- LOUNGE, window ATB-004-01 B: 600 × 1,800 mm facing SSW
- LOUNGE, window ATB-004-01 B: 2,800 × 3,600 mm facing ESE
- KLD, window ATB-006-03 B: 2,800 × 3,300 mm facing WNW
- KLD, window ATB-004-01 B: 600 × 1,800 mm facing SSW
- KLD, window ATB-006-03 B: 2,800 × 3,900 mm facing ESE
- KLD, window ATB-006-03 B: 2,800 × 3,900 mm facing NNE
- KLD, window ATB-006-03 B: 600 × 2,500 mm facing NNE
- KLD, window ATB-006-03 B: 600 × 1,800 mm facing NNE
- WC, window ATB-004-01 B: 400 × 1,100 mm facing ESE
- ENTRY, window ATB-006-03 B: 2,900 × 2,700 mm facing WNW
- ENTRY, window ATB-006-03 B: 2,700 × 300 mm facing ESE
- ENTRY, window ATB-006-03 B: 2,700 × 965 mm facing ESE
- ES1, window ATB-006-03 B: 2,800 × 900 mm facing WNW
- WIR1, window ATB-004-01 B: 500 × 1,200 mm facing NNE
- WIR1, window ATB-006-03 B: 2,800 × 900 mm facing WNW
- MB1, window ATB-006-03 B: 2,800 × 3,700 mm facing ESE
- MB1, window ATB-006-03 B: 2,800 × 3,900 mm facing NNE
- VOID 1 F, window ATB-004-01 B: 2,800 × 900 mm facing ESE
- VOID 2 F, window ATB-006-03 B: 2,900 × 2,700 mm facing WNW
- B3, window ATB-006-03 B: 2,800 × 3,000 mm facing WNW
- ES3, window ATB-006-03 B: 2,800 × 900 mm facing SSW
- ES2, window ATB-006-03 B: 2,800 × 900 mm facing SSW
- B2, window ATB-006-03 B: 2,800 × 3,900 mm facing ESE
- B2, window ATB-006-03 B: 2,800 × 3,900 mm facing NNE
- VOID 1 S, window ATB-006-04 B: 2,600 × 900 mm facing ESE
- ES4, window ATB-006-04 B: 2,600 × 1,200 mm facing WNW
- B4, window ATB-006-03 B: 2,600 × 3,000 mm facing ESE
- B4, window ATB-006-03 B: 2,600 × 1,200 mm facing NNE
- UPPER LIVING, window ATB-006-03 B: 2,600 × 2,100 mm facing ESE
- UPPER LIVING, window ATB-006-03 B: 2,600 × 3,000 mm facing NNE
- UPPER LIVING, window ATB-004-01 B: 500 × 1,200 mm facing NNE
- UPPER LIVING, window ATB-004-01 B: 2,600 × 500 mm facing SSW
- UPPER LIVING, window ATB-006-04 B: 2,600 × 2,700 mm facing WNW
Certificate 6HTX47T3BE, issued 22 November 2022, from the council's DA documents. Verify this certificate
BASIX certificate, certificate 1163808S_03, issued 22 November 2022
BASIX certificate
- Energy score
- 53 (target 50)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Heating load
- 40 MJ/m² a year
- Cooling load
- 25 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 245.6 m²
- Site area
- 525 m²
- Roof area
- 135 m²
- Garden area
- 129 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 1.5 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
Heating
- Living area: airconditioning ducting only; Energy rating: n/a
- Bedroom: airconditioning ducting only; Energy rating: n/a
Cooling
- Living area: airconditioning ducting only; Energy rating: n/a
- Bedroom: airconditioning ducting only; Energy rating: n/a
Certificate 1163808S_03, issued 22 November 2022, from the council's DA documents.