Skip to main content

6 Epping Road Double Bay NSW 2028

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 8.4 stars out of 10. Its BASIX certificate commits it to 6.6 kW of solar panels and a 2,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 88 against 72 for energy and 44 against 40 for water.

Key features

Windows
21 windows and glazed doors
Wall insulation
R1.7
Roof and ceiling insulation
Ceiling R4.5, R6, roof Waterproofing Membrane Bulk Insulation, No Air Gap Above R1.3, medium colour
Hot water
Gas storage with a performance of 4 stars
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

BASIX certificate

Energy score
88 (target 72)
Water score
44 (target 40)
Thermal performance
Pass
Materials score
-59
Heating load
12 MJ/m² a year
Cooling load
5 MJ/m² a year
Bedrooms
4
Conditioned floor area
177.5 m²
Unconditioned floor area
18.9 m²
Site area
269 m²
Roof area
136 m²
Garden area
84 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas storage with a performance of 4 stars
Solar panels
6.6 kW
Rainwater tank
2,000 litres
Fixtures
Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 81.2 m², single glazing 81.2 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - H2 treated softwood (no added insulation)
  • External wall: cavity brick; frame: no frame. all external walls rockwool batts, roll or pump-in
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: none.)

Certificate 1768788S_02, issued 8 July 2025, from the council's DA documents.

NatHERS certificate

Star rating
8.4 stars
Rated with
BERS Pro v5.2.2 (3.23)
Rated on
15 Oct 2024
Wall insulation
R1.7
Ceiling insulation
R4.5, R6
Floor insulation
R1.7, R4.5
LED downlights
76
Living room glazing by direction
N 17.4 m², E 19.2 m²
All glazing by direction
N 29.9 m², E 30.8 m², S 1.6 m², W 19 m²

Roof

  • Waterproofing Membrane Bulk Insulation, No Air Gap Above R1.3, medium colour
  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R2.3, medium colour

Window schedule

  • Kitchen/Living HAFWS-045-033-001 W-09: 3,000 × 3,540 mm facing E
  • Kitchen/Living HAAWS-050-030-001 W-05: 3,000 × 900 mm facing N
  • Kitchen/Living HAAWS-050-030-001 W-06: 3,000 × 900 mm facing N
  • Kitchen/Living HASDD-035-069-001 W-07: 3,000 × 2,850 mm facing E
  • Kitchen/Living HASDD-035-069-001 W-08: 3,000 × 4,000 mm facing N
  • Bedroom 4 HASWS-045-045-001 W-01: 2,550 × 1,850 mm facing W
  • Study HASWS-045-045-001 W-02: 2,550 × 1,850 mm facing W
  • Bath_GF HAAWS-050-030-001 W-03: 3,000 × 1,000 mm facing N
  • Laundry HAAWS-050-030-001 W-04: 3,000 × 1,000 mm facing N
  • Void HAFWS-045-033-001: 2,050 × 1,140 mm facing W
  • Media HAAWS-050-030-001: 900 × 2,400 mm facing N
  • Master Bed HAAWS-050-030-001 W-17: 900 × 2,400 mm facing N
  • Master Bed HASDD-035-069-001: 2,700 × 2,850 mm facing E
  • Master Bed HAAWS-050-030-001: 2,400 × 1,140 mm facing E
  • Master ENS HAAWS-050-030-001: 900 × 1,800 mm facing S
  • Bath_FF HALWS-050-033-001: 2,200 × 550 mm facing E
  • Bedroom 3 HACWS-055-037-001 W-22: 2,250 × 800 mm facing W
  • Bedroom 3 HACWS-055-037-001: 2,250 × 800 mm facing W
  • Bedroom 2 HACWS-055-037-001: 2,250 × 800 mm facing W
  • Bedroom 2 HACWS-055-037-001: 2,250 × 800 mm facing W
  • Bedroom 2 HAAWS-050-030-001: 900 × 2,400 mm facing N

Certificate 0009813296-01, issued 15 October 2024, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1768788S, issued 15 October 2024

BASIX certificate

Energy score
88 (target 72)
Water score
43 (target 40)
Thermal performance
Pass
Materials score
-59
Heating load
12 MJ/m² a year
Cooling load
5 MJ/m² a year
Bedrooms
4
Conditioned floor area
177.5 m²
Unconditioned floor area
18.9 m²
Site area
269 m²
Roof area
136 m²
Garden area
84 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas storage with a performance of 4 stars
Solar panels
6.6 kW
Rainwater tank
2,000 litres
Fixtures
Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 81.2 m², single glazing 81.2 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - H2 treated softwood (no added insulation)
  • External wall: cavity brick; frame: no frame. all external walls rockwool batts, roll or pump-in
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: none.)

Certificate 1768788S, issued 15 October 2024, from the council's DA documents.

BASIX certificate, certificate 1373225S, issued 20 October 2023

BASIX certificate

Energy score
72 (target 72)
Water score
41 (target 40)
Thermal performance
Pass
Materials score
-47
Heating load
18 MJ/m² a year
Cooling load
12 MJ/m² a year
Bedrooms
4
Conditioned floor area
250 m²
Unconditioned floor area
21 m²
Site area
269 m²
Roof area
159 m²
Garden area
75 m²
Climate zone
NatHERS climate zone 56
Hot water
Electric storage
Solar panels
1.6 kW
Rainwater tank
1,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Maximum glazing
aluminium frames 66 m², double glazing 66 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 Star (old label)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 Star (old label)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 Star (old label)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 Star (old label)

Construction and insulation

  • Floor: concrete slab on ground (polystyrene)
  • Garage floor: concrete slab on ground (polystyrene)
  • External wall: concrete panel/plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Internal wall: single skin masonry; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - untreated softwood (ceiling: none; roof: foil/sarking.)

Certificate 1373225S, issued 20 October 2023, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related