North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
6 Epping Road Double Bay NSW 2028
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 8.4 stars out of 10. Its BASIX certificate commits it to 6.6 kW of solar panels and a 2,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 88 against 72 for energy and 44 against 40 for water.
Key features
- Windows
- 21 windows and glazed doors
- Wall insulation
- R1.7
- Roof and ceiling insulation
- Ceiling R4.5, R6, roof Waterproofing Membrane Bulk Insulation, No Air Gap Above R1.3, medium colour
- Hot water
- Gas storage with a performance of 4 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 88 (target 72)
- Water score
- 44 (target 40)
- Thermal performance
- Pass
- Materials score
- -59
- Heating load
- 12 MJ/m² a year
- Cooling load
- 5 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 177.5 m²
- Unconditioned floor area
- 18.9 m²
- Site area
- 269 m²
- Roof area
- 136 m²
- Garden area
- 84 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas storage with a performance of 4 stars
- Solar panels
- 6.6 kW
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 81.2 m², single glazing 81.2 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - H2 treated softwood (no added insulation)
- External wall: cavity brick; frame: no frame. all external walls rockwool batts, roll or pump-in
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil backed blanket.)
- Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: none.)
Certificate 1768788S_02, issued 8 July 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 8.4 stars
- Rated with
- BERS Pro v5.2.2 (3.23)
- Rated on
- 15 Oct 2024
- Wall insulation
- R1.7
- Ceiling insulation
- R4.5, R6
- Floor insulation
- R1.7, R4.5
- LED downlights
- 76
- Living room glazing by direction
- N 17.4 m², E 19.2 m²
- All glazing by direction
- N 29.9 m², E 30.8 m², S 1.6 m², W 19 m²
Roof
- Waterproofing Membrane Bulk Insulation, No Air Gap Above R1.3, medium colour
- Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R2.3, medium colour
Window schedule
- Kitchen/Living HAFWS-045-033-001 W-09: 3,000 × 3,540 mm facing E
- Kitchen/Living HAAWS-050-030-001 W-05: 3,000 × 900 mm facing N
- Kitchen/Living HAAWS-050-030-001 W-06: 3,000 × 900 mm facing N
- Kitchen/Living HASDD-035-069-001 W-07: 3,000 × 2,850 mm facing E
- Kitchen/Living HASDD-035-069-001 W-08: 3,000 × 4,000 mm facing N
- Bedroom 4 HASWS-045-045-001 W-01: 2,550 × 1,850 mm facing W
- Study HASWS-045-045-001 W-02: 2,550 × 1,850 mm facing W
- Bath_GF HAAWS-050-030-001 W-03: 3,000 × 1,000 mm facing N
- Laundry HAAWS-050-030-001 W-04: 3,000 × 1,000 mm facing N
- Void HAFWS-045-033-001: 2,050 × 1,140 mm facing W
- Media HAAWS-050-030-001: 900 × 2,400 mm facing N
- Master Bed HAAWS-050-030-001 W-17: 900 × 2,400 mm facing N
- Master Bed HASDD-035-069-001: 2,700 × 2,850 mm facing E
- Master Bed HAAWS-050-030-001: 2,400 × 1,140 mm facing E
- Master ENS HAAWS-050-030-001: 900 × 1,800 mm facing S
- Bath_FF HALWS-050-033-001: 2,200 × 550 mm facing E
- Bedroom 3 HACWS-055-037-001 W-22: 2,250 × 800 mm facing W
- Bedroom 3 HACWS-055-037-001: 2,250 × 800 mm facing W
- Bedroom 2 HACWS-055-037-001: 2,250 × 800 mm facing W
- Bedroom 2 HACWS-055-037-001: 2,250 × 800 mm facing W
- Bedroom 2 HAAWS-050-030-001: 900 × 2,400 mm facing N
Certificate 0009813296-01, issued 15 October 2024, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate, certificate 1768788S, issued 15 October 2024
BASIX certificate
- Energy score
- 88 (target 72)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Materials score
- -59
- Heating load
- 12 MJ/m² a year
- Cooling load
- 5 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 177.5 m²
- Unconditioned floor area
- 18.9 m²
- Site area
- 269 m²
- Roof area
- 136 m²
- Garden area
- 84 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas storage with a performance of 4 stars
- Solar panels
- 6.6 kW
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 81.2 m², single glazing 81.2 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - H2 treated softwood (no added insulation)
- External wall: cavity brick; frame: no frame. all external walls rockwool batts, roll or pump-in
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil backed blanket.)
- Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: none.)
Certificate 1768788S, issued 15 October 2024, from the council's DA documents.
BASIX certificate, certificate 1373225S, issued 20 October 2023
BASIX certificate
- Energy score
- 72 (target 72)
- Water score
- 41 (target 40)
- Thermal performance
- Pass
- Materials score
- -47
- Heating load
- 18 MJ/m² a year
- Cooling load
- 12 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 250 m²
- Unconditioned floor area
- 21 m²
- Site area
- 269 m²
- Roof area
- 159 m²
- Garden area
- 75 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric storage
- Solar panels
- 1.6 kW
- Rainwater tank
- 1,500 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Maximum glazing
- aluminium frames 66 m², double glazing 66 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 Star (old label)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 Star (old label)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 Star (old label)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 Star (old label)
Construction and insulation
- Floor: concrete slab on ground (polystyrene)
- Garage floor: concrete slab on ground (polystyrene)
- External wall: concrete panel/plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Internal wall: single skin masonry; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
- Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - untreated softwood (ceiling: none; roof: foil/sarking.)
Certificate 1373225S, issued 20 October 2023, from the council's DA documents.
Is this your home? Ask us to remove these details.