North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
47C Drumalbyn Road Bellevue Hill NSW 2023
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 1.2 kW of solar panels and an 8,000 litre rainwater tank. It beat its BASIX energy target, scoring 79 against 72.
Key features
- Windows
- Up to composite frames 137.5 m², double glazing 137.5 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking; Ceiling: fibreglass batts or roll; roof: not specified
- Hot water
- Gas instantaneous with a performance of 4 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
Built by Bellevarde Constructions.
BASIX certificate
- Energy score
- 79 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -93
- Heating load
- 15 MJ/m² a year
- Cooling load
- 11 MJ/m² a year
- Bedrooms
- 2
- Conditioned floor area
- 351.8 m²
- Unconditioned floor area
- 5.9 m²
- Site area
- 1,061 m²
- Roof area
- 319 m²
- Garden area
- 503 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 4 stars
- Solar panels
- 1.2 kW
- Rainwater tank
- 8,000 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 4 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- composite frames 137.5 m², double glazing 137.5 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (polystyrene)
- External wall: concrete block/plasterboard; frame: timber - untreated softwood. all external walls fibreglass batts or roll
- Internal wall: plasterboard; frame: timber - untreated softwood (not specified)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, light steel frame (ceiling: fibreglass batts or roll; roof: foil/sarking.)
- Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: not specified.)
Certificate 1776026S_02, issued 7 April 2026, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1776026S, issued 4 December 2024
BASIX certificate
- Energy score
- 72 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 18 MJ/m² a year
- Cooling load
- 11 MJ/m² a year
- Bedrooms
- 2
- Conditioned floor area
- 348.7 m²
- Unconditioned floor area
- 8.6 m²
- Site area
- 1,061 m²
- Roof area
- 319 m²
- Garden area
- 503 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric instantaneous
- Solar panels
- 1.2 kW
- Rainwater tank
- 8,000 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 4 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- uPVC frames 134.6 m², double glazing 134.6 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (not specified)
- External wall: concrete block/plasterboard; frame: timber - untreated softwood. all external walls fibreglass batts or roll
- Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, light steel frame (ceiling: fibreglass batts or roll; roof: not specified.)
- Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: not specified.)
Certificate 1776026S, issued 4 December 2024, from the council's DA documents.
Is this your home? Ask us to remove these details.