North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
23 Wunulla Road Point Piper NSW 2027
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 50,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 54 against 40.
Key features
- Windows
- 61 windows and glazed doors: Al Thermally Broken B DG Argon Fill High Solar Gain low-E -Clear; Al Thermally Broken A DG Argon Fill High Solar Gain low-E -Clear
- Wall insulation
- R2.0
- Roof and ceiling insulation
- Ceiling R2.0, R3.0, roof Slab:Slab - Suspended Slab : 400mm: 400mm Suspended Slab 0.0, medium colour
- Hot water
- Electric boosted solar with a performance of more than 45 STCs
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 72 (target 72)
- Water score
- 54 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 22 MJ/m² a year
- Cooling load
- 8 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 473.1 m²
- Unconditioned floor area
- 149.7 m²
- Site area
- 756 m²
- Roof area
- 287 m²
- Garden area
- 253 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric boosted solar with a performance of more than 45 STCs
- Rainwater tank
- 50,000 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- timber frames 169.6 m², double glazing 169.6 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 7 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 7 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 7 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 7 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (not specified)
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: light steel frame (not specified)
- Garage floor: concrete slab on ground (not specified)
- External wall: concrete block/plasterboard; frame: light steel frame. all external walls fibreglass batts or roll
- External garage wall: concrete block/plasterboard; frame: light steel frame (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: single skin masonry; frame: light steel frame (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, light steel frame (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1803404S, issued 9 July 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 21 Jul 2025
- Wall insulation
- R2.0
- Ceiling insulation
- R2.0, R3.0
- Floor insulation
- R2.0, R1.5
- Living room glazing by direction
- NE 9 m², E 4.5 m², SE 11.8 m², NW 9 m²
- All glazing by direction
- NE 55 m², E 4.5 m², SE 55.3 m², S 5 m², SW 23.4 m², NW 26.3 m²
Roof
- Slab:Slab - Suspended Slab : 400mm: 400mm Suspended Slab 0.0, medium colour
- Slab:Slab - Suspended Slab : 200mm: 200mm Suspended Slab 0.0, medium colour
- SlabExt:Slab - Suspended Slab - External Insul : 200mm: 200mm Suspended Slab - External Insul 0.0, medium colour
- GreenRoofExtensive:Slab - 100mm Substrate : 300mm:300mm Slab - 100mm Substrate 0.0, medium colour
Window types
- ATB-006-03 B Al Thermally Broken B DG Argon Fill High Solar Gain low-E -Clear: U-value 2.9, SHGC 0.51
- ATB-005-03 B Al Thermally Broken A DG Argon Fill High Solar Gain low-E -Clear: U-value 2.91, SHGC 0.44
Window schedule
- GF FOYER, window ATB-006-03 B: 3,300 × 830 mm facing SW
- GF FOYER, window ATB-006-03 B: 3,300 × 1,600 mm facing SW
- GF FOYER, window ATB-006-03 B: 3,300 × 830 mm facing S
- GF FOYER, window ATB-005-03 B: 3,000 × 1,600 mm facing NE
- GF FOYER, window ATB-006-03 B: 3,000 × 1,873 mm facing NE
- GF FOYER, window ATB-006-03 B: 3,000 × 1,873 mm facing NE
- OUTDOOR ALFRESCO, window ATB-005-03 B: 2,100 × 1,600 mm facing SE
- OUTDOOR ALFRESCO, window ATB-006-03 B: 700 × 1,600 mm facing SE
- OUTDOOR ALFRESCO, window ATB-005-03 B: 2,100 × 1,600 mm facing SE
- OUTDOOR ALFRESCO, window ATB-006-03 B: 700 × 1,600 mm facing SE
- OUTDOOR ALFRESCO, window ATB-005-03 B: 2,100 × 1,600 mm facing SE
- OUTDOOR ALFRESCO, window ATB-006-03 B: 700 × 1,600 mm facing SE
- OUTDOOR ALFRESCO, window ATB-006-03 B: 3,000 × 950 mm facing NE
- OUTDOOR ALFRESCO, window ATB-006-03 B: 3,000 × 950 mm facing NE
- DINING ROOM, window ATB-005-03 B: 2,100 × 1,600 mm facing NW
- DINING ROOM, window ATB-006-03 B: 700 × 1,600 mm facing NW
- DINING ROOM, window ATB-005-03 B: 2,100 × 1,600 mm facing NW
- DINING ROOM, window ATB-006-03 B: 700 × 1,600 mm facing NW
- DINING ROOM, window ATB-006-03 B: 3,000 × 950 mm facing SE
- LOUNGE ROOM, window ATB-005-03 B: 2,100 × 1,600 mm facing SE
- LOUNGE ROOM, window ATB-006-03 B: 700 × 1,600 mm facing SE
- LOUNGE ROOM, window ATB-005-03 B: 2,100 × 1,600 mm facing SE
- LOUNGE ROOM, window ATB-006-03 B: 700 × 1,600 mm facing SE
- LOUNGE ROOM, window ATB-005-03 B: 2,100 × 1,600 mm facing NE
- LOUNGE ROOM, window ATB-006-03 B: 700 × 1,600 mm facing NE
- LOUNGE ROOM, window ATB-005-03 B: 2,100 × 1,600 mm facing NE
- LOUNGE ROOM, window ATB-006-03 B: 700 × 1,600 mm facing NE
- KIT/LIV/DIN, window ATB-005-03 B: 2,100 × 1,600 mm facing E
- KIT/LIV/DIN, window ATB-006-03 B: 700 × 1,600 mm facing E
- GF BED, window ATB-005-03 B: 2,100 × 1,600 mm facing SE
- GF BED, window ATB-006-03 B: 700 × 1,600 mm facing SE
- ENS2, window ATB-005-03 B: 2,000 × 1,100 mm facing NW
- ENS2, window ATB-005-03 B: 2,000 × 1,100 mm facing NE
- WIR2, window ATB-005-03 B: 2,000 × 1,100 mm facing NW
- BED2, window ATB-005-03 B: 2,000 × 1,100 mm facing NE
- BED2, window ATB-005-03 B: 2,000 × 1,100 mm facing SE
- BED2, window ATB-005-03 B: 2,000 × 1,100 mm facing SE
- BED3, window ATB-005-03 B: 2,300 × 1,100 mm facing NW
- BED3, window ATB-005-03 B: 2,000 × 1,100 mm facing NW
- FF HALL, window ATB-006-03 B: 2,700 × 830 mm facing SW
- FF HALL, window ATB-006-03 B: 2,700 × 1,600 mm facing SW
- FF HALL, window ATB-006-03 B: 2,700 × 830 mm facing S
- FF HALL, window ATB-005-03 B: 2,000 × 1,600 mm facing SE
- FF HALL, window ATB-006-03 B: 2,700 × 4,615 mm facing NE
- FF HALL, window ATB-006-03 B: 2,700 × 1,560 mm facing SE
- ENS3, window ATB-005-03 B: 2,000 × 1,100 mm facing NW
- ENS3, window ATB-005-03 B: 2,000 × 1,100 mm facing SW
- ENS4, window ATB-005-03 B: 2,000 × 1,100 mm facing SW
- BED4, window ATB-006-03 B: 2,700 × 600 mm facing NW
- BED4, window ATB-005-03 B: 2,000 × 1,100 mm facing SW
- BED4, window ATB-005-03 B: 2,000 × 1,100 mm facing SW
- BED5, window ATB-005-03 B: 2,300 × 1,600 mm facing NE
- BED5, window ATB-005-03 B: 2,000 × 1,600 mm facing SE
- BED5, window ATB-005-03 B: 2,000 × 1,600 mm facing SE
- MASTER BED, window ATB-005-03 B: 2,300 × 1,600 mm facing SE
- MASTER BED, window ATB-005-03 B: 2,300 × 1,600 mm facing SE
- MASTER BED, window ATB-005-03 B: 2,000 × 1,100 mm facing NE
- WIR MASTER, window ATB-005-03 B: 2,000 × 1,100 mm facing NW
- ENS MASTER, window ATB-005-03 B: 2,000 × 1,100 mm facing NW
- ENS MASTER, window ATB-005-03 B: 700 × 1,100 mm facing NE
- ENS MASTER, window ATB-005-03 B: 700 × 1,100 mm facing NE
Certificate E6EXHKJCSB-07, issued 21 July 2025, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate, certificate 1770910S, issued 30 October 2024
BASIX certificate
- Energy score
- 74 (target 72)
- Water score
- 51 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 1 MJ/m² a year
- Cooling load
- 10 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 332.1 m²
- Unconditioned floor area
- 137.5 m²
- Site area
- 756 m²
- Roof area
- 372 m²
- Garden area
- 195 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric boosted solar with a performance of more than 45 STCs
- Rainwater tank
- 50,000 litres
- Fixtures
- Showerheads 4 star, toilets 6 star, kitchen taps 6 star, basin taps 6 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- timber frames 101 m², double glazing 101 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, 30% cement substitute, conventional slab (fibreglass batts or roll)
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: light steel frame (not specified+ foil/sarking)
- Garage floor: concrete slab on ground, 30% cement substitute (fibreglass batts or roll)
- External wall: concrete block/plasterboard; frame: light steel frame. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: concrete block/plasterboard; frame: light steel frame (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, concrete - plasterboard internal, light steel frame (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1770910S, issued 30 October 2024, from the council's DA documents.
NatHERS certificate, certificate E6EXHKJCSB-01, issued 22 October 2024
NatHERS certificate
- Star rating
- 7.1 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 22 Oct 2024
- Wall insulation
- R2.0
- Ceiling insulation
- R2.0, R1.0
- Floor insulation
- R2.0
- Living room glazing by direction
- E 5.5 m², SE 16.2 m², S 5.9 m², NW 10.3 m²
- All glazing by direction
- NE 40.1 m², E 5.5 m², SE 35.1 m², S 8.9 m², SW 7.9 m², W 3 m², NW 25.4 m²
Roof
- Slab:Slab - Suspended Slab : 200mm: 200mm Suspended Slab 0.0, medium colour
- SlabExt:Slab - Suspended Slab - External Insul : 300mm: 300mm Suspended Slab - External Insul 0.0, medium colour
- Slab:Slab - Suspended Slab : 300mm: 300mm Suspended Slab 0.0, medium colour
- GreenRoofExtensive:Slab - 100mm Substrate : 300mm:300mm Slab - 100mm Substrate 0.0, medium colour
Window types
- ATB-005-03 B Al Thermally Broken A DG Argon Fill High Solar Gain low-E -Clear: U-value 2.91, SHGC 0.44
- ATB-006-03 B Al Thermally Broken B DG Argon Fill High Solar Gain low-E -Clear: U-value 2.9, SHGC 0.51
- ALM-002-01 A Aluminium B SG Clear: U-value 6.7, SHGC 0.7
Window schedule
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,900 mm facing NW
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,900 mm facing NW
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,100 mm facing SE
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,100 mm facing SE
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,100 mm facing SE
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,100 mm facing S
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,100 mm facing S
- KITCHEN, window ATB-005-03 B: 2,700 × 2,700 mm facing SE
- KITCHEN, window ATB-006-03 B: 2,700 × 2,050 mm facing E
- BED GF, window ATB-006-03 B: 2,700 × 1,500 mm facing SE
- ENTRY, window ATB-006-03 B: 3,300 × 500 mm facing S
- ENTRY, window ATB-006-03 B: 3,300 × 500 mm facing SW
- ENTRY, window ATB-006-03 B: 3,300 × 500 mm facing W
- ENTRY, window ATB-006-03 B: 3,000 × 3,201 mm facing NE
- ENTRY, window ATB-005-03 B: 2,300 × 2,100 mm facing NE
- ENTRY, window ATB-006-03 B: 700 × 2,100 mm facing NE
- ENTRY, window ATB-006-03 B: 3,000 × 700 mm facing NE
- MASTERBED, window ATB-006-03 B: 2,400 × 1,400 mm facing SE
- MASTERBED, window ATB-006-03 B: 2,400 × 1,400 mm facing SE
- MASTERBED, window ATB-006-03 B: 2,400 × 900 mm facing NE
- ENSUITE MASTER, window ALM-002-01 A: 2,400 × 900 mm facing NE
- BED4, window ATB-006-03 B: 2,700 × 500 mm facing NW
- BED4, window ATB-006-03 B: 2,700 × 1,800 mm facing SW
- BED2, window ATB-005-03 B: 1,800 × 900 mm facing SE
- BED2, window ATB-005-03 B: 1,800 × 900 mm facing SE
- BED2, window ATB-006-03 B: 2,700 × 900 mm facing NW
- BED2, window ATB-006-03 B: 2,700 × 900 mm facing NW
- ENS2, window ALM-002-01 A: 2,700 × 900 mm facing NW
- ENS3, window ALM-002-01 A: 2,700 × 900 mm facing NW
- BED3, window ATB-006-03 B: 2,700 × 1,500 mm facing NW
- FF HALL, window ATB-006-03 B: 2,700 × 6,600 mm facing NE
- FF HALL, window ATB-006-03 B: 2,700 × 1,800 mm facing SE
- FF HALL, window ATB-006-03 B: 2,700 × 500 mm facing S
- FF HALL, window ATB-006-03 B: 2,700 × 500 mm facing SW
- FF HALL, window ATB-006-03 B: 2,700 × 500 mm facing W
Certificate E6EXHKJCSB-01, issued 22 October 2024, from the council's DA documents. Verify this certificate
BASIX certificate, certificate 1751960S, issued 18 June 2024
BASIX certificate
- Energy score
- 73 (target 72)
- Water score
- 50 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 21 MJ/m² a year
- Cooling load
- 9 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 330.2 m²
- Unconditioned floor area
- 139.3 m²
- Site area
- 756 m²
- Roof area
- 384 m²
- Garden area
- 174 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric boosted solar with a performance of more than 45 STCs
- Rainwater tank
- 10,000 litres
- Fixtures
- Showerheads 4 star, toilets 6 star, kitchen taps 6 star, basin taps 6 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- timber frames 101 m², double glazing 101 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 7 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 7 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 7 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 7 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, 30% cement substitute, conventional slab (fibreglass batts or roll)
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: light steel frame (not specified+ foil/sarking)
- Garage floor: concrete slab on ground, 30% cement substitute (fibreglass batts or roll)
- External wall: concrete block/plasterboard; frame: light steel frame. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: concrete block/plasterboard; frame: light steel frame (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, concrete - plasterboard internal, light steel frame (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1751960S, issued 18 June 2024, from the council's DA documents.
NatHERS certificate, certificate E6EXHKJCSB, issued 12 June 2024
NatHERS certificate
- Star rating
- 7.1 stars
- Rated with
- FirstRate5: 5.5.5 (3.22)
- Rated on
- 12 Jun 2024
- Wall insulation
- R2.0
- Ceiling insulation
- R2.0, R1.0
- Floor insulation
- R2.0
- Living room glazing by direction
- E 5.5 m², SE 22.1 m², NW 10.3 m²
- All glazing by direction
- NE 40.1 m², E 5.5 m², SE 39.6 m², SW 4.9 m², NW 24 m²
Roof
- Slab:Slab - Suspended Slab : 200mm: 200mm Suspended Slab 0.0, medium colour
- SlabExt:Slab - Suspended Slab - External Insul : 300mm: 300mm Suspended Slab - External Insul 0.0, medium colour
- GreenRoofExtensive:Slab - 100mm Substrate : 300mm:300mm Slab - 100mm Substrate 0.0, medium colour
Window types
- ATB-005-03 B Al Thermally Broken A DG Argon Fill High Solar Gain low-E -Clear: U-value 2.91, SHGC 0.44
- ATB-006-03 B Al Thermally Broken B DG Argon Fill High Solar Gain low-E -Clear: U-value 2.9, SHGC 0.51
- ALM-002-01 A Aluminium B SG Clear: U-value 6.7, SHGC 0.7
Window schedule
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,900 mm facing NW
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,900 mm facing NW
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,100 mm facing SE
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,100 mm facing SE
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,100 mm facing SE
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,100 mm facing SE
- LOUNGE ROOM, window ATB-005-03 B: 2,700 × 1,100 mm facing SE
- KITCHEN, window ATB-005-03 B: 2,700 × 2,700 mm facing SE
- KITCHEN, window ATB-006-03 B: 2,700 × 2,050 mm facing E
- BED GF, window ATB-006-03 B: 2,100 × 1,500 mm facing SE
- ENTRY, window ATB-006-03 B: 3,000 × 3,201 mm facing NE
- ENTRY, window ATB-005-03 B: 2,300 × 2,100 mm facing NE
- ENTRY, window ATB-006-03 B: 700 × 2,100 mm facing NE
- ENTRY, window ATB-006-03 B: 3,000 × 700 mm facing NE
- MASTERBED, window ATB-006-03 B: 2,400 × 1,400 mm facing SE
- MASTERBED, window ATB-006-03 B: 2,400 × 1,400 mm facing SE
- MASTERBED, window ATB-006-03 B: 2,400 × 900 mm facing NE
- ENSUITE MASTER, window ALM-002-01 A: 2,400 × 900 mm facing NE
- BED4, window ATB-006-03 B: 2,700 × 500 mm facing NW
- BED4, window ATB-006-03 B: 2,700 × 1,800 mm facing SW
- BED2, window ATB-005-03 B: 1,500 × 900 mm facing SE
- BED2, window ATB-005-03 B: 1,500 × 900 mm facing SE
- BED2, window ATB-006-03 B: 2,700 × 900 mm facing NW
- BED2, window ATB-006-03 B: 2,700 × 900 mm facing NW
- ENS2, window ALM-002-01 A: 2,700 × 900 mm facing NW
- ENS3, window ALM-002-01 A: 2,700 × 900 mm facing NW
- BED3, window ATB-006-03 B: 1,800 × 1,500 mm facing NW
- FF HALL, window ATB-006-03 B: 2,700 × 6,600 mm facing NE
- FF HALL, window ATB-006-03 B: 2,700 × 1,800 mm facing SE
Certificate E6EXHKJCSB, issued 12 June 2024, from the council's DA documents. Verify this certificate