Skip to main content

217 Hopetoun Avenue Vaucluse NSW 2030

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 1.3 kW of solar panels and a 2,000 litre rainwater tank.

Key features

Windows
21 windows and glazed doors: Aluminium B SG Low Solar Gain Low-E; Aluminium A DG Argon Fill Low Solar Gain low-E -Clear; Aluminium B DG Argon Fill Low Solar Gain low-E -Clear
Wall insulation
All external walls polystyrene
Roof and ceiling insulation
Roof Added insulation absorptance Roof Colour SLAB-200-CEIL-01: Concrete Slab (200mm) with Suspended PB Ceiling 0.00, light colour
Hot water
Gas instantaneous with a performance of 5 stars
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

Built by Rozanova Building Solutions.

BASIX certificate

Energy score
72 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
18 MJ/m² a year
Cooling load
12 MJ/m² a year
Bedrooms
4
Conditioned floor area
206.5 m²
Unconditioned floor area
16.8 m²
Site area
453 m²
Roof area
140 m²
Garden area
158 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 5 stars
Solar panels
1.3 kW
Rainwater tank
2,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 103.6 m², single glazing 4.4 m², double glazing 99.2 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (polystyrene)
  • Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: timber - untreated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - untreated softwood (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: light steel frame (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: cavity brick; frame: no frame. all external walls polystyrene
  • External garage wall: concrete block/plasterboard; frame: no frame (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (polystyrene)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: none.)

Certificate 1793168S, issued 28 April 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
Hero 4.1
Rated on
28 Apr 2025
Living room glazing by direction
NE 3.4 m², NW 3.4 m²
All glazing by direction
NE 32.7 m², SE 36.8 m², SW 9.7 m², NW 25.1 m²

Roof

  • Added insulation absorptance Roof Colour SLAB-200-CEIL-01: Concrete Slab (200mm) with Suspended PB Ceiling 0.00, light colour
  • SLAB-200-EXP-01: Concrete Slab (200mm) with Exposed Concrete Ceiling 0.00, medium colour
  • SLAB-200-GREEN-01: Concrete Slab (200mm) with Green Roof (500mm) & Suspended PB Ceiling 0.00, medium colour

Window types

  • ALM-002-04 A Aluminium B SG Low Solar Gain Low-E: U-value 5.6, SHGC 0.41
  • ALM-005-04 A Aluminium A DG Argon Fill Low Solar Gain low-E -Clear: U-value 4.8, SHGC 0.34
  • ALM-006-04 A Aluminium B DG Argon Fill Low Solar Gain low-E -Clear: U-value 4.8, SHGC 0.34

Window schedule

  • BATH FF, window ALM-006-04 A: 1,000 × 1,800 mm facing NE
  • BEDROOM 2, window ALM-006-04 A: 1,000 × 3,490 mm facing NE
  • BEDROOM 2, window ALM-006-04 A: 2,800 × 2,410 mm facing SE
  • BEDROOM 3, window ALM-006-04 A: 2,800 × 2,410 mm facing SE
  • BEDROOM 4, window ALM-006-04 A: 1,000 × 1,810 mm facing SW
  • ENS MB, window ALM-006-04 A: 1,000 × 3,760 mm facing NE
  • ENS MB, window ALM-006-04 A: 1,300 × 2,700 mm facing NW
  • ENTRY/HALL, window ALM-005-04 A: 3,100 × 1,200 mm facing NE
  • FAMILY, window ALM-006-04 A: 2,100 × 798 mm facing NE
  • FAMILY, window ALM-002-04 A: 2,100 × 798 mm facing NE
  • FAMILY, window ALM-006-04 A: 2,100 × 1,595 mm facing NW
  • GARAGE, window ALM-006-04 A: 500 × 1,800 mm facing SW
  • KLD, window ALM-006-04 A: 3,000 × 3,010 mm facing NE
  • KLD, window ALM-006-04 A: 3,000 × 1,125 mm facing NE
  • KLD, window ALM-006-04 A: 3,000 × 6,875 mm facing SE
  • KLD, window ALM-002-04 A: 3,000 × 900 mm facing SE
  • LDRY, window ALM-005-04 A: 2,400 × 800 mm facing SW
  • MASTER BEDROOM, window ALM-006-04 A: 2,800 × 4,325 mm facing NW
  • MASTER BEDROOM, window ALM-005-04 A: 2,800 × 1,500 mm facing NE
  • STAIRS FF, window ALM-006-04 A: 2,800 × 1,810 mm facing SW
  • STUDY, window ALM-006-04 A: 2,100 × 2,915 mm facing NW

Certificate HR-3HUXT4-01, issued 28 April 2025, from the council's DA documents. Verify this certificate