Skip to main content

177 Underwood Street Paddington NSW 2021

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 4 kW of solar panels and a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 86 against 72.

Key features

Windows
18 windows and glazed doors: Premium Siteline Clad-Tim w Al Fixed SG 3Clr; Cedar Hinged Door SG 3Clr; Cedar Sliding Door SG 5Clr and 2 more types
Wall insulation
R2.0
Roof and ceiling insulation
Ceiling R4.1, R2.5, roof Slab:Slab - Suspended Slab : 200mm: 200mm Suspended Slab 0.0, medium colour
Hot water
Electric heat pump with a performance of 21 to 25 STCs or better
Air conditioning and heating
1-phase airconditioning, non ducted (living area and bedroom); 1-phase airconditioning, ducted (bedroom)

Built by Paul King.

BASIX certificate

Energy score
86 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-70
Heating load
23 MJ/m² a year
Cooling load
7 MJ/m² a year
Bedrooms
4
Conditioned floor area
345 m²
Unconditioned floor area
30 m²
Site area
396 m²
Roof area
188 m²
Garden area
121 m²
Climate zone
NatHERS climate zone 56
Hot water
Electric heat pump with a performance of 21 to 25 STCs or better
Solar panels
4 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
timber frames 53 m², double glazing 53 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 5 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: cavity brick; frame: no frame (polystyrene)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (metal clad); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: concrete panel/plasterboard; frame: no frame (polystyrene)
  • External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1739015S_04, issued 28 January 2026, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
28 Jan 2026
Wall insulation
R2.0
Ceiling insulation
R4.1, R2.5
Floor insulation
R2.0, R2.3, R1.0, R2.5
Living room glazing by direction
SW 4.6 m²
All glazing by direction
NE 30 m², SW 15.7 m², NW 5.6 m²

Roof

  • Slab:Slab - Suspended Slab : 200mm: 200mm Suspended Slab 0.0, medium colour
  • Framed:Flat - Flat Framed (Metal Deck) 0.0, light colour
  • Cont:Attic-Continuous 0.0, light colour

Window types

  • STG-054-01 W Premium Siteline Clad-Tim w Al Fixed SG 3Clr: U-value 5.34, SHGC 0.75
  • STG-037-01 W Cedar Hinged Door SG 3Clr: U-value 4.26, SHGC 0.55
  • STG-021-02 W Cedar Sliding Door SG 5Clr: U-value 4.47, SHGC 0.55
  • STG-069-02 W Alumiere Casement Window SG 5CLR: U-value 6.4, SHGC 0.61
  • STG-019-03 W Cedar Double Hung Window SG 5Clr: U-value 4.71, SHGC 0.61

Window schedule

  • Entry, window STG-054-01 W: 2,570 × 450 mm facing SW
  • Formal Living, window STG-037-01 W: 2,570 × 900 mm facing SW
  • Formal Living, window STG-037-01 W: 2,570 × 900 mm facing SW
  • Kitch/Fam/Livin- g, window STG-021-02 W: 3,270 × 4,200 mm facing NE
  • Kitch/Fam/Livin- g, window STG-037-01 W: 3,270 × 620 mm facing NE
  • Hallway 2, window STG-069-02 W: 2,100 × 892 mm facing SW
  • Master Bedroom, window STG-021-02 W: 2,700 × 2,950 mm facing NE
  • Master Bedroom, window STG-069-02 W: 1,800 × 1,140 mm facing NW
  • Walk-In-Robe, window STG-069-02 W: 1,800 × 900 mm facing NW
  • Bedroom 2, window STG-069-02 W: 1,800 × 1,300 mm facing NE
  • Bedroom 1, window STG-037-01 W: 2,450 × 900 mm facing SW
  • Bedroom 1, window STG-037-01 W: 2,450 × 900 mm facing SW
  • Bedroom 1, window STG-037-01 W: 2,450 × 900 mm facing SW
  • Master Ensuite, window STG-069-02 W: 1,800 × 1,050 mm facing NW
  • Upper Hallway 2, window STG-019-03 W: 1,400 × 1,000 mm facing SW
  • Studio, window STG-019-03 W: 1,400 × 1,000 mm facing NE
  • Attic Bedroom, window STG-069-02 W: 1,350 × 950 mm facing NE
  • Attic Bedroom, window STG-069-02 W: 1,350 × 950 mm facing NE

Certificate 9MUZJJJ38A, issued 28 January 2026, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1739015S_02, issued 31 July 2024

BASIX certificate

Energy score
87 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-75
Heating load
23 MJ/m² a year
Cooling load
7 MJ/m² a year
Bedrooms
4
Conditioned floor area
316.6 m²
Unconditioned floor area
34 m²
Site area
396 m²
Roof area
188 m²
Garden area
121 m²
Climate zone
NatHERS climate zone 56
Hot water
Electric heat pump with a performance of 21 to 25 STCs or better
Solar panels
4 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
timber frames 53 m², double glazing 53 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 5 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: cavity brick; frame: no frame (polystyrene)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (metal clad); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: concrete panel/plasterboard; frame: no frame (polystyrene)
  • External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1739015S_02, issued 31 July 2024, from the council's DA documents.

BASIX certificate, certificate 1739015S, issued 7 March 2024

BASIX certificate

Energy score
87 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-74
Heating load
22 MJ/m² a year
Cooling load
8 MJ/m² a year
Bedrooms
4
Conditioned floor area
316.6 m²
Unconditioned floor area
34 m²
Site area
396 m²
Roof area
188 m²
Garden area
121 m²
Climate zone
NatHERS climate zone 56
Hot water
Electric heat pump with a performance of 21 to 25 STCs or better
Solar panels
4 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
timber frames 42.4 m², double glazing 42.4 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 5 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: cavity brick; frame: no frame (polystyrene)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (metal clad); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: concrete panel/plasterboard; frame: no frame (polystyrene)
  • External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1739015S, issued 7 March 2024, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related