BASIX certificate and NatHERS rating
This home has a NatHERS rating of 5.4 stars out of 10. Its BASIX certificate commits it to 8 kW of solar panels and an 8,000 litre rainwater tank. It beat its BASIX energy target, scoring 56 against 50.
Key features
- Windows
- 44 windows and glazed doors: Al Thermally Broken A DG Argon Fill High Solar Gain low-E - Clear; Al Thermally Broken B DG Argon Fill High Solar Gain low-E - Clear
- Roof and ceiling insulation
- Roof Added insulation absorptance Roof Colour SLAB-200-EXP-01: Concrete Slab (200mm) with Exposed Concrete Ceiling 0.00, light colour
- Hot water
- Solar (gas boosted, evacuated tube) with a performance of 31 to 35 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
Built by The Construction Connection.
BASIX certificate
- Energy score
- 56 (target 50)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Heating load
- 40 MJ/m² a year
- Cooling load
- 26 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 966.3 m²
- Unconditioned floor area
- 73.7 m²
- Site area
- 1,300 m²
- Roof area
- 328 m²
- Garden area
- 370 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Solar (gas boosted, evacuated tube) with a performance of 31 to 35 STCs or better
- Solar panels
- 8 kW
- Rainwater tank
- 8,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Certificate 1320024S_02, issued 12 July 2022, from the council's DA documents.
NatHERS certificate
- Star rating
- 5.4 stars
- Rated with
- Hero 2.0
- Rated on
- 12 July 2022
- Living room glazing by direction
- SE 32.7 m², SW 75.2 m², NW 34.3 m²
- All glazing by direction
- NE 95.8 m², SE 62.3 m², SW 197.2 m², WSW 26 m², NW 89.5 m²
Roof
- Added insulation absorptance Roof Colour SLAB-200-EXP-01: Concrete Slab (200mm) with Exposed Concrete Ceiling 0.00, light colour
- SLAB-200-GREEN-01: Concrete Slab (200mm) with Green Roof (500mm) with Suspended PB Ceiling 0.00, light colour
Window types
- ATB-005-03 B Al Thermally Broken A DG Argon Fill High Solar Gain low-E - Clear: U-value 2.91, SHGC 0.44
- ATB-006-03 B Al Thermally Broken B DG Argon Fill High Solar Gain low-E - Clear: U-value 2.9, SHGC 0.51
Window schedule
- Bed 1, window ATB-006-03 B: 2,500 × 6,750 mm facing SW
- Bed 1 Ensuite, window ATB-005-03 B: 2,500 × 930 mm facing NW
- Bed 1 Ensuite, window ATB-006-03 B: 2,500 × 768 mm facing NW
- Bed 1 Ensuite, window ATB-005-03 B: 2,500 × 3,807 mm facing SW
- Bed 2, window ATB-006-03 B: 2,500 × 380 mm facing NE
- Bed 2, window ATB-006-03 B: 2,500 × 4,180 mm facing NE
- Bed 2, window ATB-006-03 B: 2,500 × 400 mm facing SW
- Bed 2 Ensuite, window ATB-005-03 B: 2,500 × 2,200 mm facing NE
- Bed 3, window ATB-006-03 B: 2,500 × 4,200 mm facing SW
- Bed 3 Ensuite, window ATB-005-03 B: 2,500 × 2,250 mm facing NW
- Bed 4, window ATB-006-03 B: 2,500 × 4,085 mm facing SW
- Bed 4 Ensuite, window ATB-005-03 B: 2,500 × 1,960 mm facing NE
- Bed 4 Ensuite, window ATB-005-03 B: 2,500 × 1,960 mm facing NE
- Bed 4 WIR, window ATB-005-03 B: 2,500 × 1,190 mm facing NE
- Entry Void, window ATB-006-03 B: 2,500 × 10,050 mm facing SW
- Entry Void, window ATB-006-03 B: 2,500 × 1,245 mm facing NW
- Entry Void, window ATB-006-03 B: 2,500 × 9,160 mm facing NW
- Entry Void, window ATB-005-03 B: 2,460 × 1,740 mm facing NE
- Entry Void, window ATB-006-03 B: 2,500 × 7,270 mm facing SE
- Entry Void, window ATB-006-03 B: 2,500 × 1,815 mm facing NE
- Gym/Bar, window ATB-006-03 B: 2,450 × 10,600 mm facing WSW
- LIVING, window ATB-006-03 B: 3,000 × 7,270 mm facing SE
- LIVING, window ATB-006-03 B: 3,000 × 1,500 mm facing SW
- LIVING, window ATB-006-03 B: 3,000 × 1,500 mm facing SW
- LIVING, window ATB-006-03 B: 3,000 × 7,060 mm facing SW
- LIVING, window ATB-006-03 B: 3,000 × 9,160 mm facing NW
- Living Dining Kitchen, window ATB-006-03 B: 2,500 × 2,955 mm facing SW
- Living Dining Kitchen, window ATB-006-03 B: 2,500 × 4,350 mm facing SE
- Living Dining Kitchen, window ATB-005-03 B: 3,000 × 12,546 mm facing SW
- Living Dining Kitchen, window ATB-006-03 B: 2,500 × 2,745 mm facing NW
- Mezzanine, window ATB-006-03 B: 2,500 × 2,900 mm facing SW
- Mezzanine, window ATB-006-03 B: 2,500 × 1,305 mm facing SE
- Mezzanine, window ATB-006-03 B: 2,500 × 12,546 mm facing SW
- Mezzanine, window ATB-005-03 B: 2,500 × 3,050 mm facing NW
- Mezzanine, window ATB-006-03 B: 2,500 × 2,700 mm facing NW
- Mezzanine, window ATB-006-03 B: 2,500 × 12,490 mm facing NE
- Mezzanine, window ATB-006-03 B: 2,500 × 865 mm facing NW
- Mezzanine, window ATB-006-03 B: 2,500 × 2,500 mm facing SE
- Pantry, window ATB-006-03 B: 2,500 × 2,600 mm facing NE
- Study, window ATB-006-03 B: 2,500 × 770 mm facing SE
- Study, window ATB-005-03 B: 2,500 × 4,069 mm facing SW
- WC, window ATB-006-03 B: 2,500 × 240 mm facing NE
- WIR Dressing, window ATB-006-03 B: 2,500 × 1,081 mm facing NW
- WIR Dressing, window ATB-006-03 B: 2,500 × 7,600 mm facing NE
Certificate HR-OUCJVQ-01, issued 12 July 2022, from the council's DA documents.