Skip to main content

113 Victoria Road Bellevue Hill NSW 2023

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 5.5 stars out of 10. Its BASIX certificate commits it to a 16,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 51 against 50 for energy and 49 against 40 for water.

Key features

Windows
43 windows and glazed doors: Timber A SG Clear; Aluminium A SG Clear; Aluminium B SG Clear
Wall insulation
R0.8, R3.8, R2.5
Roof and ceiling insulation
Ceiling R2.5, R3, roof Waterproofing Membrane No Insulation, Only an Air Gap, medium colour
Hot water
Ground source heat pump (closed loop) only
Air conditioning and heating
Ground source heat pump (closed loop) (living area and bedroom)

Built by Reform Projects.

BASIX certificate

Energy score
51 (target 50)
Water score
49 (target 40)
Thermal performance
Pass
Heating load
37 MJ/m² a year
Cooling load
21 MJ/m² a year
Bedrooms
7
Conditioned floor area
522.3 m²
Unconditioned floor area
61 m²
Site area
880 m²
Roof area
427 m²
Garden area
400 m²
Climate zone
NatHERS climate zone 56
Hot water
Ground source heat pump (closed loop) only
Rainwater tank
16,000 litres
Fixtures
Showerheads 4 star, toilets 3 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes

Heating

  • Living area: ground source heat pump (closed loop); Energy rating: EER 5.0 - 5.5
  • Bedroom: ground source heat pump (closed loop); Energy rating: EER 5.0 - 5.5 A certificate of specifications issued by

Cooling

  • Living area: ground source heat pump (closed loop); Energy rating: EER 4.0 - 4.5
  • Bedroom: ground source heat pump (closed loop); Energy rating: EER 4.0 - 4.5 A certificate of specifications issued by

Certificate 1222538S_03, issued 11 November 2021, from the council's DA documents.

NatHERS certificate

Star rating
5.5 stars
Rated with
BERS Pro v4.4.0.6 (3.21)
Rated on
10 Nov 2021
Wall insulation
R0.8, R3.8, R2.5
Ceiling insulation
R2.5, R3
Floor insulation
R1, R2.5
Living room glazing by direction
NE 36.6 m², SE 3.5 m², SW 2.7 m²
All glazing by direction
NE 80.8 m², SE 19.1 m², SW 23.5 m², NW 22.8 m²

Roof

  • Waterproofing Membrane No Insulation, Only an Air Gap, medium colour
  • Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
  • Corrugated Iron No Insulation, Only an Air Gap, medium colour

Window types

  • TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
  • ALM-001-01 A Aluminium A SG Clear: U-value 6.7, SHGC 0.57
  • ALM-002-01 A Aluminium B SG Clear: U-value 6.7, SHGC 0.7

Window schedule

  • Laundry, window TIM-001-01 W: 1,835 × 2,100 mm facing NW
  • Laundry, window ALM-001-01 A: 2,700 × 1,000 mm facing NE
  • Bedroom 3, window TIM-001-01 W: 1,835 × 2,100 mm facing NW
  • Bath2, window TIM-001-01 W: 1,500 × 770 mm facing NW
  • Bedroom 4, window TIM-001-01 W: 1,835 × 900 mm facing NW
  • Bedroom 4, window ALM-001-01 A: 2,700 × 2,180 mm facing NE
  • Rumpus, window ALM-002-01 A: 2,700 × 4,700 mm facing NE
  • Bath, window ALM-001-01 A: 2,700 × 1,000 mm facing NE
  • Bath, window TIM-001-01 W: 1,050 × 1,800 mm facing SE
  • Bedroom 5, window TIM-001-01 W: 1,835 × 2,100 mm facing SE
  • Bath 3, window TIM-001-01 W: 1,500 × 770 mm facing SE
  • Bedroom 6, window ALM-001-01 A: 2,700 × 2,180 mm facing NE
  • Bedroom 6, window TIM-001-01 W: 1,835 × 900 mm facing SE
  • Ensuite, window TIM-001-01 W: 1,835 × 770 mm facing NW
  • Ensuite, window TIM-001-01 W: 1,835 × 1,000 mm facing NE
  • Study, window TIM-001-01 W: 1,835 × 900 mm facing NW
  • Study, window ALM-001-01 A: 2,700 × 1,100 mm facing SW
  • Study, window ALM-001-01 A: 2,700 × 1,100 mm facing SW
  • Bedroom 1, window TIM-001-01 W: 1,835 × 900 mm facing NW
  • Bedroom 1, window TIM-001-01 W: 1,835 × 900 mm facing NW
  • Bedroom 1, window ALM-001-01 A: 2,660 × 1,470 mm facing NE
  • Bedroom 1, window ALM-001-01 A: 2,660 × 765 mm facing NE
  • Bedroom 1, window ALM-001-01 A: 2,660 × 765 mm facing NE
  • Entry, window ALM-001-01 A: 2,870 × 1,850 mm facing SW
  • Powder, window TIM-001-01 W: 1,150 × 600 mm facing SW
  • Bedroom 2, window TIM-001-01 W: 1,835 × 900 mm facing SE
  • Bedroom 2, window TIM-001-01 W: 1,835 × 900 mm facing SE
  • Pantry, window TIM-001-01 W: 1,500 × 840 mm facing SE
  • Mud, window ALM-001-01 A: 2,620 × 1,800 mm facing NW
  • Kitchen/Living, window ALM-001-01 A: 2,660 × 1,470 mm facing NE
  • Kitchen/Living, window ALM-002-01 A: 2,660 × 5,370 mm facing NE
  • Kitchen/Living, window ALM-001-01 A: 2,660 × 765 mm facing NE
  • Kitchen/Living, window ALM-001-01 A: 2,660 × 765 mm facing NE
  • Kitchen/Living, window ALM-002-01 A: 1,835 × 1,920 mm facing SE
  • Kitchen/Living, window TIM-001-01 W: 1,835 × 900 mm facing NE
  • Kitchen/Living, window ALM-001-01 A: 2,700 × 1,010 mm facing SW
  • Bath 2, window TIM-001-01 W: 1,500 × 770 mm facing NW
  • Bath 5, window TIM-001-01 W: 1,500 × 770 mm facing SE
  • Bath 1, window TIM-001-01 W: 1,060 × 900 mm facing SE
  • Bed 7, window ALM-001-01 A: 1,400 × 3,030 mm facing SW
  • Library, window ALM-001-01 A: 2,600 × 6,637 mm facing NE
  • Gallery, window ALM-001-01 A: 1,400 × 3,260 mm facing SW
  • Plantrooms, window TIM-001-01 W: 620 × 600 mm facing SE

Certificate 0006205793-03, issued 10 November 2021, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1180743S, issued 16 July 2021

BASIX certificate

Energy score
51 (target 50)
Water score
41 (target 40)
Thermal performance
Pass
Heating load
39 MJ/m² a year
Cooling load
26 MJ/m² a year
Bedrooms
7
Conditioned floor area
454 m²
Unconditioned floor area
17 m²
Site area
880 m²
Roof area
424 m²
Garden area
400 m²
Climate zone
NatHERS climate zone 56
Hot water
Ground source heat pump (closed loop) only
Rainwater tank
14,500 litres
Fixtures
Showerheads 4 star, toilets 3 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes

Heating

  • Living area: ground source heat pump (closed loop); Energy rating: EER 5.0 - 5.5
  • Bedroom: ground source heat pump (closed loop); Energy rating: EER 5.5 - 6.0 A certificate of specifications issued by

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Certificate 1180743S, issued 16 July 2021, from the council's DA documents.

BASIX certificate (alterations and additions), certificate A391513_02, issued 16 November 2020

BASIX certificate (alterations and additions)

This BASIX certificate is for alterations and additions, such as an extension or a pool, rather than a whole new house.

LED lighting
Yes

Construction and insulation

  • Concrete slab on ground floor with in-slab heating system. R1.00 (slab edge) in-slab heating system
  • Floor above existing dwelling or building (no added insulation)
  • External wall: cavity brick (no added insulation)
  • External wall: framed (weatherboard, fibro, metal clad) R1.30 (or R1.70 including construction)
  • Flat ceiling, pitched roof ceiling: R1.45 (up), roof: foil backed blanket (55 mm) medium (solar absorptance 0.475 - 0.70)

Certificate A391513_02, issued 16 November 2020, from the council's DA documents.