North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
9 Station Street Balmoral NSW 2571
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 4.7 stars out of 10. Its BASIX certificate commits it to a 50,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 81 against 40.
Key features
- Windows
- 22 windows and glazed doors: Timber B DG Air Fill Low Solar Gain low-E -Clear
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R5, roof Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 50 (target 50)
- Water score
- 81 (target 40)
- Thermal performance
- Pass
- Heating load
- 61 MJ/m² a year
- Cooling load
- 60 MJ/m² a year
- Bedrooms
- 2
- Conditioned floor area
- 86 m²
- Unconditioned floor area
- 6 m²
- Site area
- 18,111 m²
- Roof area
- 139 m²
- Garden area
- 100 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 50,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Clothes line
- Yes
Heating
- Living area: 1-phase airconditioning; Energy rating: 8 star (average zone)
- Bedroom: 1-phase airconditioning; Energy rating: 8 star (average zone)
Cooling
- Living area: 1-phase airconditioning; Energy rating: 8 star (average zone)
- Bedroom: 1-phase airconditioning; Energy rating: 8 star (average zone)
Certificate 1204861S, issued 10 January 2022, from the council's DA documents.
NatHERS certificate
- Star rating
- 4.7 stars
- Rated with
- BERS Pro v4.4.0.6 (3.21)
- Rated on
- 22 Dec 2021
- Wall insulation
- R2.5
- Ceiling insulation
- R5
- Floor insulation
- R1
- LED downlights
- 38
- Living room glazing by direction
- N 10.3 m², E 9.2 m², S 4.3 m², W 2.7 m²
- All glazing by direction
- N 10.3 m², E 26.3 m², S 7.7 m², W 12.4 m²
Roof
- Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour
Window types
- TIM-004-04 W Timber B DG Air Fill Low Solar Gain low-E -Clear: U-value 2.3, SHGC 0.25
Window schedule
- Kitchen/Living, window TIM-004-04 W: 1,850 × 2,000 mm facing S
- Kitchen/Living, window TIM-004-04 W: 1,230 × 500 mm facing S
- Kitchen/Living, window TIM-004-04 W: 700 × 1,225 mm facing W
- Kitchen/Living, window TIM-004-04 W: 700 × 2,550 mm facing W
- Kitchen/Living, window TIM-004-04 W: 2,300 × 2,000 mm facing N
- Kitchen/Living, window TIM-004-04 W: 2,100 × 1,800 mm facing N
- Kitchen/Living, window TIM-004-04 W: 2,100 × 920 mm facing N
- Kitchen/Living, window TIM-004-04 W: 2,300 × 4,000 mm facing E
- Hall/laundry, window TIM-004-04 W: 2,300 × 3,120 mm facing E
- Hall/laundry, window TIM-004-04 W: 2,100 × 920 mm facing S
- Hall/laundry, window TIM-004-04 W: 2,180 × 1,200 mm facing W
- Hall/laundry, window TIM-004-04 W: 2,180 × 960 mm facing W
- Hall/laundry, window TIM-004-04 W: 2,180 × 960 mm facing W
- Bed 1, window TIM-004-04 W: 2,100 × 2,000 mm facing E
- Bed 1, window TIM-004-04 W: 1,650 × 900 mm facing E
- Bed 1, window TIM-004-04 W: 900 × 500 mm facing S
- Bed 1, window TIM-004-04 W: 900 × 500 mm facing S
- Bed 2, window TIM-004-04 W: 2,100 × 2,000 mm facing E
- Bath, window TIM-004-04 W: 630 × 900 mm facing S
- Bath, window TIM-004-04 W: 1,230 × 800 mm facing W
- Study, window TIM-004-04 W: 1,230 × 1,100 mm facing W
- Laundry, window TIM-004-04 W: 1,230 × 500 mm facing W
Certificate 0006960769, issued 22 December 2021, from the council's DA documents. Verify this certificate