BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 6.6 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy target, scoring 91 against 63.
Key features
- Windows
- Up to aluminium frames 46.2 m², timber frames 0.7 m², single glazing 0.7 m², double glazing 46.2 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 91 (target 63)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -93
- Heating load
- 117 MJ/m² a year
- Cooling load
- 3 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 223.2 m²
- Unconditioned floor area
- 13.2 m²
- Site area
- 22,680 m²
- Roof area
- 370 m²
- Garden area
- 500 m²
- Climate zone
- NatHERS climate zone 24
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 6.6 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 46.2 m², timber frames 0.7 m², single glazing 0.7 m², double glazing 46.2 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: light steel frame (fibreglass batts or roll)
- External wall: framed (solid or reconstituted timber weatherboard); frame: light steel frame (fibreglass batts or roll)
- External garage wall: brick veneer; frame: light steel frame (fibreglass batts or roll)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: light steel frame (fibreglass batts or roll)
- Internal wall: plasterboard; frame: light steel frame (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, light steel frame (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1808695S_02, issued 10 December 2025, from the council's DA documents.