North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
50 Lyell Street Mittagong NSW 2575
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 8 kW of solar panels and a 5,000 litre rainwater tank. It beat its BASIX energy target, scoring 96 against 63.
Key features
- Windows
- Up to aluminium frames 24.6 m², single glazing 4.9 m², double glazing 19.8 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 96 (target 63)
- Water score
- 40 (target 40)
- Materials score
- 13
- Heating load
- 110 MJ/m² a year
- Cooling load
- 12 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 115.7 m²
- Unconditioned floor area
- 14.9 m²
- Site area
- 1,012 m²
- Roof area
- 231 m²
- Garden area
- 168 m²
- Climate zone
- NatHERS climate zone 24
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Solar panels
- 8 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 5 star, toilets 3 star, kitchen taps 6 star, basin taps 6 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 24.6 m², single glazing 4.9 m², double glazing 19.8 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: suspended floor above enclosed subfloor, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1827314S_03, issued 15 May 2026, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1827314S_02, issued 18 February 2026
BASIX certificate
- Energy score
- 97 (target 63)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Materials score
- 27
- Heating load
- 109 MJ/m² a year
- Cooling load
- 13 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 136 m²
- Unconditioned floor area
- 3.4 m²
- Site area
- 1,012 m²
- Roof area
- 149 m²
- Garden area
- 500 m²
- Climate zone
- NatHERS climate zone 24
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Solar panels
- 8 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 4 star, toilets 3 star, kitchen taps 6 star, basin taps 6 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 25.2 m², single glazing 1.1 m², double glazing 24.1 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: suspended floor above enclosed subfloor, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1827314S_02, issued 18 February 2026, from the council's DA documents.
Is this your home? Ask us to remove these details.