North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
2726 Canyonleigh Road Canyonleigh NSW 2577
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 1 kW of solar panels and a 100,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 66 against 63 for energy and 43 against 40 for water.
Key features
- Windows
- Up to aluminium frames 293.3 m², double glazing 293.3 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking; Polystyrene
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 66 (target 63)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 84 MJ/m² a year
- Cooling load
- 24 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 521.4 m²
- Unconditioned floor area
- 17.4 m²
- Site area
- 409,500 m²
- Roof area
- 745 m²
- Garden area
- 800 m²
- Climate zone
- NatHERS climate zone 24
- Hot water
- Electric heat pump
- Solar panels
- 1 kW
- Rainwater tank
- 100,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 293.3 m², double glazing 293.3 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: concrete panel/plasterboard; frame: no frame (polystyrene)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1812761S, issued 12 September 2025, from the council's DA documents.