North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
Lot 2711, 23 Arkose Road Gables NSW 2765
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 71 against 70 for energy and 55 against 40 for water.
Key features
- Windows
- 25 windows and glazed doors: Aluminium B SG Clear; 502/504 Al Sliding Window SG 6.38CP; RES SERIES 516 FIXED WINDOW SG 638ComPlsClr and 2 more types
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R2.5, R6.0, roof Framed:Flat - Flat Framed (Metal Deck) 0.0, medium colour
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, non ducted (living area and bedroom)
Built by Persco Constructions.
BASIX certificate
- Energy score
- 71 (target 70)
- Water score
- 55 (target 40)
- Thermal performance
- Pass
- Materials score
- -73
- Heating load
- 42 MJ/m² a year
- Cooling load
- 18 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 295.6 m²
- Unconditioned floor area
- 16 m²
- Site area
- 450 m²
- Roof area
- 275 m²
- Garden area
- 182 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 58.2 m², single glazing 58.2 m²
Heating
- Living area: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1792562S_02, issued 29 April 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 15 Apr 2025
- Wall insulation
- R2.5
- Ceiling insulation
- R2.5, R6.0
- Floor insulation
- R2.5
- Living room glazing by direction
- SE 8.2 m², SW 15.3 m², NW 10.3 m²
- All glazing by direction
- NE 12 m², SE 12.7 m², SW 17.6 m², NW 15.8 m²
Roof
- Framed:Flat - Flat Framed (Metal Deck) 0.0, medium colour
- Cont:Attic-Continuous 1.8, medium colour
Window types
- ALM-002-01 A Aluminium B SG Clear: U-value 6.7, SHGC 0.7
- AWS-001-05 A 502/504 Al Sliding Window SG 6.38CP: U-value 4.59, SHGC 0.45
- AWS-066-03 A RES SERIES 516 FIXED WINDOW SG 638ComPlsClr: U-value 3.91, SHGC 0.62
- AWS-007-07 A 516 Al Awining Window SG 6.38CP: U-value 4.92, SHGC 0.41
- AWS-011-06 A 541/542 Al Sliding Door SG 6.38CP: U-value 4.38, SHGC 0.45
Window schedule
- Garage, window AWS-001-05 A: 600 × 1,210 mm facing NW
- Study, window AWS-066-03 A: 2,060 × 610 mm facing NE
- Study, window AWS-007-07 A: 2,060 × 1,210 mm facing NE
- ENS, window AWS-001-05 A: 860 × 850 mm facing SE
- Media, window AWS-001-05 A: 600 × 2,100 mm facing SE
- Kitchen/Living, window AWS-001-05 A: 1,500 × 3,010 mm facing NW
- Kitchen/Living, window AWS-011-06 A: 2,400 × 3,610 mm facing SW
- Kitchen/Living, window AWS-011-06 A: 2,400 × 2,410 mm facing NW
- Kitchen/Living, window AWS-066-03 A: 1,800 × 3,010 mm facing SW
- Kitchen/Living, window AWS-001-05 A: 600 × 2,410 mm facing SE
- Kitchen/Living, window AWS-007-07 A: 1,800 × 610 mm facing SE
- Kitchen/Living, window AWS-007-07 A: 1,800 × 610 mm facing SE
- Pantry, window AWS-001-05 A: 600 × 1,810 mm facing NW
- Bedroom 2, window AWS-007-07 A: 1,500 × 3,010 mm facing NE
- Bedroom 3, window AWS-001-05 A: 860 × 1,810 mm facing NW
- Bath, window ALM-002-01 A: 1,200 × 1,810 mm facing NW
- Bedroom 4, window AWS-001-05 A: 860 × 1,810 mm facing SW
- ENS4, window AWS-007-07 A: 1,200 × 610 mm facing SW
- ENS Master, window AWS-001-05 A: 1,200 × 1,210 mm facing SE
- Bedroom Master, window AWS-007-07 A: 1,200 × 850 mm facing SE
- Bedroom Master, window AWS-066-03 A: 2,060 × 610 mm facing NE
- Bedroom Master, window AWS-007-07 A: 2,060 × 1,210 mm facing NE
- Rumpus, window AWS-001-05 A: 600 × 2,100 mm facing SW
- Rumpus, window AWS-001-05 A: 860 × 2,410 mm facing SE
- Rumpus, window AWS-066-03 A: 2,060 × 1,210 mm facing SE
Certificate QD0E5X6B9Q, issued 15 April 2025, from the council's DA documents. Verify this certificate
Is this your home? Ask us to remove these details.