Lot-31, Cosmos Way Box Hill NSW 2765

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor.

Key features

Windows
17 windows and glazed doors: Aluminium A DG Air Fill High Solar Gain low-E -Clear; Aluminium B DG Air Fill High Solar Gain low-E -Clear; Aluminium B SG High Solar Gain Low-E and 2 more types
Wall insulation
R2.7
Roof and ceiling insulation
Ceiling R4.0, R2.5, R6.0, roof Cont:Attic-Continuous 0.0, dark colour
Hot water
Gas instantaneous with a performance of 4 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
70 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-88
Heating load
31 MJ/m² a year
Cooling load
29 MJ/m² a year
Bedrooms
5
Conditioned floor area
135.8 m²
Unconditioned floor area
15 m²
Site area
225 m²
Roof area
111 m²
Garden area
57 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 2 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 35.8 m², single glazing 6.1 m², double glazing 29.7 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, 30% cement substitute, waffle pod slab (polystyrene)
  • Floor: suspended floor above garage, particle board; frame: timber - untreated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, 30% cement substitute, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll)
  • External wall: brick veneer; frame: timber - untreated softwood (no added insulation)
  • External wall: AAC veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
  • Internal wall: block with low cement content and reconstituted sawdust; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1798141S, issued 2 June 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
1 May 2025
Wall insulation
R2.7
Ceiling insulation
R4.0, R2.5, R6.0
Floor insulation
R3.5, R2.5, R2.7, R0.6, R2.4, R4.0
Living room glazing by direction
N 5.2 m², E 3.5 m², S 4.3 m², W 2.6 m²
All glazing by direction
N 6.8 m², E 10.6 m², S 13.7 m², W 4.8 m²

Roof

  • Cont:Attic-Continuous 0.0, dark colour
  • Cont:Attic-Continuous 1.3, dark colour

Window types

  • ALM-003-03 A Aluminium A DG Air Fill High Solar Gain low-E -Clear: U-value 4.3, SHGC 0.47
  • ALM-004-03 A Aluminium B DG Air Fill High Solar Gain low-E -Clear: U-value 4.3, SHGC 0.53
  • ALM-002-03 A Aluminium B SG High Solar Gain Low-E: U-value 5.4, SHGC 0.58
  • ALM-001-01 A Aluminium A SG Clear: U-value 6.7, SHGC 0.57
  • ALM-002-01 A Aluminium B SG Clear: U-value 6.7, SHGC 0.7

Window schedule

  • KIT / LIV / DIN, window ALM-003-03 A: 1,800 × 724 mm facing W
  • KIT / LIV / DIN, window ALM-003-03 A: 1,800 × 724 mm facing W
  • KIT / LIV / DIN, window ALM-004-03 A: 2,400 × 1,810 mm facing S
  • KIT / LIV / DIN, window ALM-003-03 A: 1,800 × 724 mm facing N
  • KIT / LIV / DIN, window ALM-004-03 A: 1,800 × 2,170 mm facing N
  • BED 5, window ALM-002-03 A: 1,800 × 1,810 mm facing S
  • L'DRY / WIP, window ALM-001-01 A: 1,800 × 724 mm facing S
  • PDR, window ALM-002-01 A: 600 × 724 mm facing N
  • LIVING, window ALM-004-03 A: 2,400 × 410 mm facing E
  • LIVING, window ALM-004-03 A: 2,050 × 1,210 mm facing E
  • BED 4, window ALM-004-03 A: 1,200 × 1,810 mm facing W
  • BATH FF, window ALM-002-01 A: 600 × 724 mm facing N
  • ENS, window ALM-002-03 A: 600 × 1,210 mm facing N
  • BED M, window ALM-004-03 A: 1,800 × 2,170 mm facing E
  • HALL / FOYER FF, window ALM-004-03 A: 1,800 × 1,450 mm facing S
  • BED 3, window ALM-004-03 A: 1,200 × 1,810 mm facing S
  • BED 2, window ALM-004-03 A: 1,800 × 1,810 mm facing E

Certificate 748SW8ANRC, issued 1 May 2025, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.