Skip to main content

Lot-28, Sagitta Street Box Hill NSW 2765

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the ceiling and floor. It beat its BASIX water target, scoring 46 against 40.

Key features

Windows
15 windows and glazed doors: Urban 580 Sliding Window SG 4Clr; Standard Al Sliding Window SG 4ET; Capral Urban 584 Sliding Door SG 638CPClr and 3 more types
Wall insulation
Fibreglass batts or roll+ foil/sarking
Roof and ceiling insulation
Ceiling R3.0, R6.0, roof Cont:Attic-Continuous 0.0, dark colour
Hot water
Gas instantaneous with a performance of 4 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Universal Property Group.

BASIX certificate

Energy score
70 (target 70)
Water score
46 (target 40)
Thermal performance
Pass
Materials score
-55
Heating load
27 MJ/m² a year
Cooling load
33 MJ/m² a year
Bedrooms
5
Conditioned floor area
128.1 m²
Unconditioned floor area
8.9 m²
Site area
225 m²
Roof area
118 m²
Garden area
65 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 27.4 m², single glazing 27.4 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - hardwood predominant incl. glue laminated beams (no added insulation)
  • Floor: suspended floor above garage, particle board; frame: timber - hardwood predominant incl. glue laminated beams (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: AAC veneer; frame: timber - H2 treated softwood (foil/sarking)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - hardwood predominant incl. glue laminated beams (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1797347S_04, issued 7 August 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
7 Aug 2025
Ceiling insulation
R3.0, R6.0
Floor insulation
R3.0
Living room glazing by direction
S 2.6 m², W 9.8 m²
All glazing by direction
N 0.4 m², E 11.2 m², S 4.3 m², W 11.5 m²

Roof

  • Cont:Attic-Continuous 0.0, dark colour
  • Vent:Attic-Vented 0.0, dark colour

Window types

  • CAP-030-01 A Urban 580 Sliding Window SG 4Clr: U-value 6.45, SHGC 0.73
  • MTM-003-08 A Standard Al Sliding Window SG 4ET: U-value 4.6, SHGC 0.61
  • CAP-126-07 A Capral Urban 584 Sliding Door SG 638CPClr: U-value 4.23, SHGC 0.57
  • CAP-032-06 A Urban 582 Awning Window SG 638CPClr: U-value 4.87, SHGC 0.54
  • CAP-032-01 A Urban 582 Awning Window SG 4Clr: U-value 6.48, SHGC 0.65
  • GJA-011-47 A Type 130 Series Fixed Window SG 6mmEntSupGrn: U-value 3.92, SHGC 0.38

Window schedule

  • BATH, window CAP-030-01 A: 595 × 724 mm facing N
  • KIT/DIN/FAM, window MTM-003-08 A: 1,800 × 1,791 mm facing W
  • KIT/DIN/FAM, window CAP-126-07 A: 2,400 × 2,721 mm facing W
  • KIT/DIN/FAM, window CAP-032-06 A: 1,800 × 724 mm facing S
  • KIT/DIN/FAM, window CAP-032-06 A: 1,800 × 724 mm facing S
  • BED 5, window CAP-032-01 A: 2,040 × 724 mm facing E
  • BED 5, window CAP-032-01 A: 2,040 × 724 mm facing E
  • BED 3, window CAP-030-01 A: 595 × 2,150 mm facing W
  • BED 4, window CAP-032-06 A: 1,800 × 724 mm facing E
  • BED 4, window CAP-032-06 A: 1,800 × 724 mm facing E
  • MASTER BED, window MTM-003-08 A: 1,800 × 2,150 mm facing E
  • ENS, window MTM-003-08 A: 595 × 724 mm facing S
  • BED 2, window CAP-030-01 A: 595 × 2,150 mm facing S
  • BATH, window CAP-030-01 A: 595 × 724 mm facing W
  • HALL/STAIR, window GJA-011-47 A: 1,800 × 962 mm facing E

Certificate FOI4RW44L8-02, issued 7 August 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

NatHERS certificate, certificate FOI4RW44L8-01, issued 17 July 2025

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
17 Jul 2025
Ceiling insulation
R3.0, R6.0
Floor insulation
R3.0
Living room glazing by direction
S 2.6 m², W 9.8 m²
All glazing by direction
N 0.4 m², E 11.2 m², S 4.3 m², W 11.5 m²

Roof

  • Cont:Attic-Continuous 0.0, dark colour
  • Vent:Attic-Vented 0.0, dark colour

Window types

  • CAP-030-01 A Urban 580 Sliding Window SG 4Clr: U-value 6.45, SHGC 0.73
  • MTM-003-08 A Standard Al Sliding Window SG 4ET: U-value 4.6, SHGC 0.61
  • CAP-126-07 A Capral Urban 584 Sliding Door SG 638CPClr: U-value 4.23, SHGC 0.57
  • CAP-032-06 A Urban 582 Awning Window SG 638CPClr: U-value 4.87, SHGC 0.54
  • CAP-032-01 A Urban 582 Awning Window SG 4Clr: U-value 6.48, SHGC 0.65
  • GJA-011-47 A Type 130 Series Fixed Window SG 6mmEntSupGrn: U-value 3.92, SHGC 0.38

Window schedule

  • BATH, window CAP-030-01 A: 595 × 724 mm facing N
  • KIT/DIN/FAM, window MTM-003-08 A: 1,800 × 1,791 mm facing W
  • KIT/DIN/FAM, window CAP-126-07 A: 2,400 × 2,721 mm facing W
  • KIT/DIN/FAM, window CAP-032-06 A: 1,800 × 724 mm facing S
  • KIT/DIN/FAM, window CAP-032-06 A: 1,800 × 724 mm facing S
  • BED 5, window CAP-032-01 A: 2,040 × 724 mm facing E
  • BED 5, window CAP-032-01 A: 2,040 × 724 mm facing E
  • BED 3, window CAP-030-01 A: 595 × 2,150 mm facing W
  • BED 4, window CAP-032-06 A: 1,800 × 724 mm facing E
  • BED 4, window CAP-032-06 A: 1,800 × 724 mm facing E
  • MASTER BED, window MTM-003-08 A: 1,800 × 2,150 mm facing E
  • ENS, window MTM-003-08 A: 595 × 724 mm facing S
  • BED 2, window CAP-030-01 A: 595 × 2,150 mm facing S
  • BATH, window CAP-030-01 A: 595 × 724 mm facing W
  • HALL/STAIR, window GJA-011-47 A: 1,800 × 962 mm facing E

Certificate FOI4RW44L8-01, issued 17 July 2025, from the council's DA documents. Verify this certificate

BASIX certificate, certificate 1797347S_03, issued 17 July 2025

BASIX certificate

Energy score
70 (target 70)
Water score
46 (target 40)
Thermal performance
Pass
Materials score
-55
Heating load
27 MJ/m² a year
Cooling load
33 MJ/m² a year
Bedrooms
5
Conditioned floor area
128.1 m²
Unconditioned floor area
8.9 m²
Site area
225 m²
Roof area
118 m²
Garden area
65 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 27.4 m², single glazing 27.4 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - hardwood predominant incl. glue laminated beams (no added insulation)
  • Floor: suspended floor above garage, particle board; frame: timber - hardwood predominant incl. glue laminated beams (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: AAC veneer; frame: timber - H2 treated softwood (foil/sarking)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - hardwood predominant incl. glue laminated beams (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1797347S_03, issued 17 July 2025, from the council's DA documents.

NatHERS certificate, certificate FOI4RW44L8, issued 2 June 2025

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
2 Jun 2025
Ceiling insulation
R3.0, R6.0
Floor insulation
R3.0
Living room glazing by direction
S 2.6 m², W 9.8 m²
All glazing by direction
N 0.4 m², E 11.2 m², S 5.2 m², W 12.3 m²

Roof

  • Cont:Attic-Continuous 0.0, dark colour
  • Vent:Attic-Vented 0.0, dark colour

Window types

  • MTM-003-08 A Standard Al Sliding Window SG 4ET: U-value 4.6, SHGC 0.61
  • AIR-013-03 A Aluminium Composite Sliding Door DG 4/8/4EA: U-value 3, SHGC 0.54
  • CAP-032-06 A Urban 582 Awning Window SG 638CPClr: U-value 4.87, SHGC 0.54
  • GJA-011-47 A Type 130 Series Fixed Window SG 6mmEntSupGrn: U-value 3.92, SHGC 0.38

Window schedule

  • BATH, window MTM-003-08 A: 595 × 724 mm facing N
  • KIT/DIN/FAM, window MTM-003-08 A: 1,800 × 1,791 mm facing W
  • KIT/DIN/FAM, window AIR-013-03 A: 2,400 × 2,721 mm facing W
  • KIT/DIN/FAM, window CAP-032-06 A: 1,800 × 724 mm facing S
  • KIT/DIN/FAM, window CAP-032-06 A: 1,800 × 724 mm facing S
  • BED 5, window CAP-032-06 A: 2,040 × 724 mm facing E
  • BED 5, window CAP-032-06 A: 2,040 × 724 mm facing E
  • BED 3, window MTM-003-08 A: 1,197 × 1,791 mm facing W
  • BED 4, window CAP-032-06 A: 1,800 × 724 mm facing E
  • BED 4, window CAP-032-06 A: 1,800 × 724 mm facing E
  • MASTER BED, window MTM-003-08 A: 1,800 × 2,150 mm facing E
  • ENS, window MTM-003-08 A: 595 × 724 mm facing S
  • BED 2, window MTM-003-08 A: 1,197 × 1,791 mm facing S
  • BATH, window MTM-003-08 A: 595 × 724 mm facing W
  • HALL/STAIR, window GJA-011-47 A: 1,800 × 962 mm facing E

Certificate FOI4RW44L8, issued 2 June 2025, from the council's DA documents. Verify this certificate

BASIX certificate, certificate 1797347S_02, issued 2 June 2025

BASIX certificate

Energy score
70 (target 70)
Water score
46 (target 40)
Thermal performance
Pass
Materials score
-56
Heating load
25 MJ/m² a year
Cooling load
35 MJ/m² a year
Bedrooms
5
Conditioned floor area
127.6 m²
Unconditioned floor area
8.9 m²
Site area
225 m²
Roof area
118 m²
Garden area
65 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 29.1 m², single glazing 22.6 m², double glazing 6.5 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - hardwood predominant incl. glue laminated beams (no added insulation)
  • Floor: suspended floor above garage, particle board; frame: timber - hardwood predominant incl. glue laminated beams (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: AAC veneer; frame: timber - H2 treated softwood (foil/sarking)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - hardwood predominant incl. glue laminated beams (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1797347S_02, issued 2 June 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related