99 Constellation Avenue Box Hill NSW 2765

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the ceiling and floor. It beat its BASIX water target, scoring 44 against 40.

Key features

Windows
24 windows and glazed doors: Timber B SG Low Solar Gain Low-E; Type 130 Series Fixed Window SG 6mmEntSupGrn; Type 048 Series Awning Window DG 4S500-12-4 and 4 more types
Wall insulation
Fibreglass batts or roll+ foil/sarking
Roof and ceiling insulation
Ceiling R2.5, R6.0, roof Vent:Attic-Vented 0.0, dark colour
Hot water
Gas instantaneous with a performance of 4 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
70 (target 70)
Water score
44 (target 40)
Thermal performance
Pass
Materials score
-69
Heating load
33 MJ/m² a year
Cooling load
27 MJ/m² a year
Bedrooms
5
Conditioned floor area
146.3 m²
Unconditioned floor area
12.3 m²
Site area
273 m²
Roof area
129 m²
Garden area
131 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 43.1 m², timber frames 1.6 m², single glazing 12.5 m², double glazing 32.1 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - hardwood predominant incl. glue laminated beams (fibreglass batts or roll)
  • Floor: suspended floor above garage, particle board; frame: timber - hardwood predominant incl. glue laminated beams (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: AAC veneer; frame: timber - H2 treated softwood (foil/sarking)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - hardwood predominant incl. glue laminated beams (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1789104S, issued 27 March 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
27 Mar 2025
Ceiling insulation
R2.5, R6.0
Floor insulation
R2.5
Living room glazing by direction
SE 14.8 m², SW 3 m², NW 1.1 m²
All glazing by direction
NE 12.9 m², SE 23.2 m², SW 5.6 m², NW 3 m²

Roof

  • Vent:Attic-Vented 0.0, dark colour

Window types

  • TIM-002-04 W Timber B SG Low Solar Gain Low-E: U-value 3.7, SHGC 0.38
  • GJA-011-47 A Type 130 Series Fixed Window SG 6mmEntSupGrn: U-value 3.92, SHGC 0.38
  • GJA-001-53 A Type 048 Series Awning Window DG 4S500-12-4: U-value 3.51, SHGC 0.49
  • AIR-013-03 A Aluminium Composite Sliding Door DG 4/8/4EA: U-value 3, SHGC 0.54
  • STG-006-23 A Aluminium Sliding Window DG 4/8Ar/4Pt: U-value 3.6, SHGC 0.48
  • CAP-032-06 A Urban 582 Awning Window SG 638CPClr: U-value 4.87, SHGC 0.54
  • MTM-003-08 A Standard Al Sliding Window SG 4ET: U-value 4.6, SHGC 0.61

Window schedule

  • KIT/DIN/FAM, window GJA-011-47 A: 600 × 1,810 mm facing NW
  • KIT/DIN/FAM, window GJA-001-53 A: 2,050 × 724 mm facing SW
  • KIT/DIN/FAM, window GJA-001-53 A: 2,050 × 724 mm facing SW
  • KIT/DIN/FAM, window AIR-013-03 A: 2,400 × 2,675 mm facing SE
  • KIT/DIN/FAM, window STG-006-23 A: 2,050 × 2,170 mm facing SE
  • ENTRY/FOYER, window TIM-002-04 W: 2,400 × 650 mm facing NE
  • BED 1, window STG-006-23 A: 2,050 × 1,810 mm facing NE
  • BED 1, window STG-006-23 A: 600 × 1,810 mm facing SE
  • LDRY, window CAP-032-06 A: 1,800 × 724 mm facing SE
  • BATH, window MTM-003-08 A: 600 × 850 mm facing SE
  • BED 3, window STG-006-23 A: 1,800 × 1,810 mm facing NE
  • BED 3, window STG-006-23 A: 600 × 1,810 mm facing SE
  • HALLWAY/STAIR, window MTM-003-08 A: 1,200 × 1,450 mm facing NE
  • RUMPUS, window STG-006-23 A: 1,800 × 2,170 mm facing SE
  • M.BED, window GJA-001-53 A: 1,800 × 724 mm facing SW
  • M.BED, window GJA-001-53 A: 1,800 × 724 mm facing SW
  • M.BED, window GJA-001-53 A: 1,800 × 724 mm facing SE
  • M.BED, window GJA-001-53 A: 1,800 × 724 mm facing SE
  • ENS, window MTM-003-08 A: 600 × 850 mm facing NW
  • BED 5, window MTM-003-08 A: 770 × 1,810 mm facing NW
  • BED 4, window CAP-032-06 A: 1,800 × 724 mm facing NE
  • BED 4, window CAP-032-06 A: 1,800 × 724 mm facing NE
  • WC, window CAP-032-06 A: 1,800 × 724 mm facing SE
  • BATH, window MTM-003-08 A: 600 × 850 mm facing SE

Certificate ST5O1IBEVH, issued 27 March 2025, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.