98-100 Annangrove Road Kenthurst NSW 2156

BASIX certificate and NatHERS rating

Finding the block on the map…

This home's BASIX certificate commits it to 12 kW of solar panels and a 5,000 litre rainwater tank. It beat its BASIX energy target, scoring 72 against 70.

Key features

Windows
Up to uPVC frames 493.8 m², double glazing 493.8 m²
Wall insulation
All external walls rockwool batts, roll or pump-in
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
Airconditioning ducting only (living area and bedroom)

BASIX certificate

Energy score
72 (target 70)
Water score
40 (target 40)
Materials score
-100
Heating load
35 MJ/m² a year
Cooling load
25 MJ/m² a year
Bedrooms
6
Conditioned floor area
1,140.3 m²
Unconditioned floor area
65.1 m²
Site area
21,670 m²
Roof area
1,273 m²
Garden area
45 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
12 kW
Rainwater tank
5,000 litres
Fixtures
Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
uPVC frames 493.8 m², double glazing 493.8 m²

Heating

  • Living area: airconditioning ducting only; Energy rating: n/a
  • Bedroom: airconditioning ducting only; Energy rating: n/a

Cooling

  • Living area: airconditioning ducting only; Energy rating: n/a
  • Bedroom: airconditioning ducting only; Energy rating: n/a

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (polystyrene)
  • Floor: suspended floor above open subfloor, treated softwood; frame: timber - untreated softwood (no added insulation)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - untreated softwood (no added insulation)
  • Floor: suspended floor above garage, treated softwood; frame: timber - untreated softwood (no added insulation)
  • Garage floor: concrete slab on ground (polystyrene)
  • External wall: brick veneer; frame: timber - H2 treated softwood. all external walls rockwool batts, roll or pump-in
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1845428S, issued 7 May 2026, from the council's DA documents.