Skip to main content

94 Solstice Street Box Hill NSW 2765

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the ceiling and floor. It beat its BASIX water target, scoring 44 against 40.

Key features

Windows
26 windows and glazed doors: Timber B DG Argon Fill High Solar Gain low-E -Clear; Type 048 Series Awning Window DG 4S500-12-4; Aluminium Sliding Window DG 4/8Ar/4Pt and 1 more types
Wall insulation
Fibreglass batts or roll+ foil/sarking
Roof and ceiling insulation
Ceiling R2.5, R6.0, roof Cont:Attic-Continuous 0.0, dark colour
Hot water
Gas instantaneous with a performance of 4 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Universal Property Group.

BASIX certificate

Energy score
70 (target 70)
Water score
44 (target 40)
Thermal performance
Pass
Materials score
-70
Heating load
33 MJ/m² a year
Cooling load
27 MJ/m² a year
Bedrooms
5
Conditioned floor area
174 m²
Unconditioned floor area
5.5 m²
Site area
365 m²
Roof area
140 m²
Garden area
180 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 39.6 m², timber frames 1.2 m², double glazing 40.8 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - hardwood predominant incl. glue laminated beams (no added insulation)
  • Floor: suspended floor above garage, particle board; frame: timber - hardwood predominant incl. glue laminated beams (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: AAC veneer; frame: timber - H2 treated softwood (foil/sarking)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - hardwood predominant incl. glue laminated beams (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1791711S_02, issued 24 June 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
24 Jun 2025
Ceiling insulation
R2.5, R6.0
Floor insulation
R2.5
Living room glazing by direction
NE 3.9 m², SE 8.4 m², SW 3.9 m², NW 5.3 m²
All glazing by direction
NE 6 m², SE 10.6 m², SW 9.3 m², NW 14.9 m²

Roof

  • Cont:Attic-Continuous 0.0, dark colour
  • Vent:Attic-Vented 0.0, dark colour

Window types

  • TIM-006-03 W Timber B DG Argon Fill High Solar Gain low-E -Clear: U-value 2, SHGC 0.31
  • GJA-001-53 A Type 048 Series Awning Window DG 4S500-12-4: U-value 3.51, SHGC 0.49
  • STG-006-23 A Aluminium Sliding Window DG 4/8Ar/4Pt: U-value 3.6, SHGC 0.48
  • AIR-013-03 A Aluminium Composite Sliding Door DG 4/8/4EA: U-value 3, SHGC 0.54

Window schedule

  • KIT/DIN/FAM, window GJA-001-53 A: 1,800 × 724 mm facing SW
  • KIT/DIN/FAM, window GJA-001-53 A: 1,800 × 724 mm facing SW
  • KIT/DIN/FAM, window STG-006-23 A: 1,800 × 1,450 mm facing SE
  • KIT/DIN/FAM, window AIR-013-03 A: 2,400 × 2,410 mm facing SE
  • KIT/DIN/FAM, window GJA-001-53 A: 1,800 × 724 mm facing NE
  • KIT/DIN/FAM, window GJA-001-53 A: 1,800 × 724 mm facing NE
  • KIT/DIN/FAM, window GJA-001-53 A: 1,800 × 724 mm facing NE
  • BATH, window STG-006-23 A: 600 × 1,210 mm facing SW
  • G.BED, window STG-006-23 A: 770 × 1,810 mm facing SW
  • G.BED, window STG-006-23 A: 2,050 × 1,810 mm facing NW
  • LIVING, window TIM-006-03 W: 2,400 × 500 mm facing NW
  • LIVING, window GJA-001-53 A: 2,050 × 724 mm facing NW
  • HALLWAY/STAIR, window GJA-001-53 A: 2,050 × 724 mm facing SW
  • M.BED, window STG-006-23 A: 440 × 2,410 mm facing NE
  • M.BED, window GJA-001-53 A: 1,200 × 724 mm facing SE
  • M.BED, window GJA-001-53 A: 1,200 × 724 mm facing SE
  • ENS, window STG-006-23 A: 600 × 724 mm facing SW
  • WC, window STG-006-23 A: 600 × 724 mm facing SE
  • BED 5, window STG-006-23 A: 770 × 1,810 mm facing SW
  • BED 5, window STG-006-23 A: 1,800 × 1,810 mm facing NW
  • RUMPUS/HALL, window GJA-001-53 A: 1,800 × 724 mm facing SW
  • RUMPUS/HALL, window GJA-001-53 A: 1,800 × 724 mm facing NW
  • RUMPUS/HALL, window GJA-001-53 A: 1,800 × 724 mm facing NW
  • BED 3, window GJA-001-53 A: 1,800 × 724 mm facing NW
  • BED 3, window GJA-001-53 A: 1,800 × 724 mm facing NW
  • BED 4, window STG-006-23 A: 440 × 2,410 mm facing NE

Certificate ITEXI2G714-02, issued 24 June 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

NatHERS certificate, certificate ITEXI2G714, issued 14 April 2025

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
14 Apr 2025
Ceiling insulation
R2.5, R6.0
Floor insulation
R2.5
Living room glazing by direction
NE 3.9 m², SE 8.4 m², SW 3.9 m², NW 5.3 m²
All glazing by direction
NE 9 m², SE 10.6 m², SW 9.3 m², NW 14.9 m²

Roof

  • Cont:Attic-Continuous 0.0, dark colour
  • Vent:Attic-Vented 0.0, dark colour

Window types

  • TIM-006-03 W Timber B DG Argon Fill High Solar Gain low-E -Clear: U-value 2, SHGC 0.31
  • GJA-001-53 A Type 048 Series Awning Window DG 4S500-12-4: U-value 3.51, SHGC 0.49
  • STG-006-23 A Aluminium Sliding Window DG 4/8Ar/4Pt: U-value 3.6, SHGC 0.48
  • AIR-013-03 A Aluminium Composite Sliding Door DG 4/8/4EA: U-value 3, SHGC 0.54

Window schedule

  • KIT/DIN/FAM, window GJA-001-53 A: 1,800 × 724 mm facing SW
  • KIT/DIN/FAM, window GJA-001-53 A: 1,800 × 724 mm facing SW
  • KIT/DIN/FAM, window STG-006-23 A: 1,800 × 1,450 mm facing SE
  • KIT/DIN/FAM, window AIR-013-03 A: 2,400 × 2,410 mm facing SE
  • KIT/DIN/FAM, window GJA-001-53 A: 1,800 × 724 mm facing NE
  • KIT/DIN/FAM, window GJA-001-53 A: 1,800 × 724 mm facing NE
  • KIT/DIN/FAM, window GJA-001-53 A: 1,800 × 724 mm facing NE
  • BATH, window STG-006-23 A: 600 × 1,210 mm facing SW
  • G.BED, window STG-006-23 A: 770 × 1,810 mm facing SW
  • G.BED, window STG-006-23 A: 2,050 × 1,810 mm facing NW
  • LIVING, window TIM-006-03 W: 2,400 × 500 mm facing NW
  • LIVING, window GJA-001-53 A: 2,050 × 724 mm facing NW
  • HALLWAY/STAIR, window GJA-001-53 A: 2,050 × 724 mm facing SW
  • M.BED, window STG-006-23 A: 1,200 × 2,410 mm facing NE
  • M.BED, window GJA-001-53 A: 1,200 × 724 mm facing SE
  • M.BED, window GJA-001-53 A: 1,200 × 724 mm facing SE
  • ENS, window STG-006-23 A: 600 × 724 mm facing SW
  • WC, window STG-006-23 A: 600 × 724 mm facing SE
  • BED 5, window STG-006-23 A: 770 × 1,810 mm facing SW
  • BED 5, window STG-006-23 A: 1,800 × 1,810 mm facing NW
  • RUMPUS/HALL, window GJA-001-53 A: 1,800 × 724 mm facing SW
  • RUMPUS/HALL, window GJA-001-53 A: 1,800 × 724 mm facing NW
  • RUMPUS/HALL, window GJA-001-53 A: 1,800 × 724 mm facing NW
  • BED 3, window GJA-001-53 A: 1,800 × 724 mm facing NW
  • BED 3, window GJA-001-53 A: 1,800 × 724 mm facing NW
  • BED 4, window STG-006-23 A: 1,200 × 1,810 mm facing NE

Certificate ITEXI2G714, issued 14 April 2025, from the council's DA documents. Verify this certificate

BASIX certificate, certificate 1791711S, issued 14 April 2025

BASIX certificate

Energy score
70 (target 70)
Water score
44 (target 40)
Thermal performance
Pass
Materials score
-65
Heating load
31 MJ/m² a year
Cooling load
29 MJ/m² a year
Bedrooms
5
Conditioned floor area
174 m²
Unconditioned floor area
5.5 m²
Site area
365 m²
Roof area
140 m²
Garden area
180 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 42.5 m², timber frames 1.2 m², double glazing 43.7 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - hardwood predominant incl. glue laminated beams (no added insulation)
  • Floor: suspended floor above garage, particle board; frame: timber - hardwood predominant incl. glue laminated beams (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: AAC veneer; frame: timber - H2 treated softwood (foil/sarking)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - hardwood predominant incl. glue laminated beams (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1791711S, issued 14 April 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related