North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
94 Aiken Road West Pennant Hills NSW 2125
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to a 3,000 litre rainwater tank. It beat its BASIX water target, scoring 44 against 40.
Key features
- Windows
- Up to aluminium frames 50 m², single glazing 50 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Beechwood Homes.
BASIX certificate
- Energy score
- 72 (target 72)
- Water score
- 44 (target 40)
- Thermal performance
- Pass
- Materials score
- 39
- Heating load
- 15 MJ/m² a year
- Cooling load
- 14 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 114 m²
- Unconditioned floor area
- 16 m²
- Site area
- 1,040 m²
- Roof area
- 112 m²
- Garden area
- 100 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 50 m², single glazing 50 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: suspended floor above open subfloor, hard wood; frame: timber - H2 treated softwood (no added insulation)
- Floor: above habitable rooms or mezzanine, hard wood; frame: timber - H2 treated softwood (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1741391S_03, issued 18 September 2024, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1741391S, issued 26 March 2024
BASIX certificate
- Energy score
- 72 (target 72)
- Water score
- 44 (target 40)
- Thermal performance
- Pass
- Materials score
- 39
- Heating load
- 15 MJ/m² a year
- Cooling load
- 15 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 114 m²
- Unconditioned floor area
- 16 m²
- Site area
- 1,040 m²
- Roof area
- 112 m²
- Garden area
- 100 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 50 m², single glazing 50 m²
Heating
- Living area: 1-phase airconditioning - non ducted; Energy rating: 6 star (average zone)
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 6 star (average zone)
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: 6 star (average zone)
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 6 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: suspended floor above open subfloor, hard wood; frame: timber - H2 treated softwood (no added insulation)
- Floor: above habitable rooms or mezzanine, hard wood; frame: timber - H2 treated softwood (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1741391S, issued 26 March 2024, from the council's DA documents.
Is this your home? Ask us to remove these details.